3.2.1.2.9 VM FICON Channel Path Load Analysis
 
 The VM FICON Channel Path Load Analysis report provides
 information about FICON channels.  Only channels for which
 "busy" conditions occur are included. Channel paths provide
 the interface that allows for control units and I/O devices
 to be physically connected to the I/O subsystem.
 
 INTENDED USE:
 
 The report is designed to help analyze FICONS channels by
 path ID.  For each ID, percent channel utilization for the
 partition and total for the system can be analyzed to help
 detect bottlenecks in the I/O subsystem caused by excessive
 path utilization.
 
 FORMAT:
 
    A tabular listing that contains one line of information
    for each active channel configured during the reporting
    period. Report is ordered by channel path ID.  In addition
    to the channel path ID, the following columns are shown on
    the report:
 
         CHPID - Hexadecimal number of the channel path
         identifier.
 
         SHRD - Indicator for the channel which can be either
         YES for channels shared with other logical
         partitions, or NO for channels dedicated to this
         logical partition.
 
         FICON CHANNEL UTILIZATION %: The following fields
         show the relative utilization of resources compared
         to the maximum value, in percent.
 
         TOTAL FOR SYSTEM:
 
         BUS CYCLE T_BCY - The bus cycles utilization for the
         whole system.
 
         WORK UNITS T_WUN - The work units utilization for the
         whole system.
 
         DATA UNITS WRITE T_DUW - The data units write
         utilization for the whole system.
 
         DATA UNITS READ T_DUR - The data units read
         utilization for the whole system.
 
         OWN PARTITION:
 
         WORK UNITS L_WUN - The work units utilization for the
         own logical partition.
 
         DATA UNITS WRITE L_DUW - The data units write
         utilization for the own logical partition.
 
         DATA UNIT READ L_DUR - The data units read
         utilization for the own logical partition.
 
         TOTAL DATA TRANSFER RATE (BYTES/S):
 
         WRITES/S - The total number of bytes written per
         second for the whole system.
 
         READ/S - The total number of bytes read per second
         for the whole system.
 
    An example of this report is shown in Figure 3-23.
 
 INQUIRY ID:
 
    VMXLS2
 
 DATA SOURCE (File/Timespan):
 
    VMXCPM01 - DETAIL
 
 DATA ELEMENTS USED:
 
    CHANNEL  - Physical Channel Address
    CPMTYPE  - VM Channel Path Type
    CPMCMG   - VM Channel Measurement Group
    CPMCMMQ  - VM Channel Model Group Qualifier
    CPMPCPSY - VM Percent Channel Busy - CPC
    CPMCBCCT - VM Total Bus Cycles Count
    CPMSHRCT - VM Channel Path Shared
    CPMCPINT - VM Channel Path Interval Time
    CPMCWUT  - VM FICON Channel Work Unit Count - CPC
    CPMTDUW  - VM FICON Write Data Unit Count - CPC
    CPMTDUR  - VM FICON Read Data Unit Count - CPC
    CPMCWUL  - VM FICON Channel Work Unit Count - LPAR
    CPMLDUW  - VM FICON Write Data Unit Count - LPAR
    CPMLDUR  - VM FICON Read Data Unit Count - LPAR
    CPMMXIBC - VM Max FICON Internal Bus Cycles Per Second
    CPMMXUNP - VM Max FICON Channel Work Units Per Second
    CPMMXUNW - VM Max FICON Write Data Units Per Second
    CPMMXUNR - VM Max FICON Read Data Units Per Second
    CPMDUS   - VM FICON Data Unit Size
 
  CALCULATIONS:
 
    Percent average total internal bus cycle utilization:
 
     T_BCY=(CPMCBCCT*100)/CPMMXIBC/CPMCPINT;
 
    Percent average total channel work units utilization:
 
     T_WUN=(CPMCWUT*100)/CPMMXUNP/CPMCPINT;
 
    Percent average total data unit writes utilization:
 
     T_DUW=(CPMTDUW*100)/CPMMXUNW/CPMCPINT;
 
    Percent average total data unit reads utilization:
 
     T_DUR=(CPMTDUR*100)/CPMMXUNR/CPMCPINT;
 
    Percent average logical channel work unit utilization
    for the partition:
 
     L_WUN=(CPMCWUL*100)/CPMMXUNP/CPMCPINT;
 
    Percent average logical channel data unit writes
    utilization for the partition:
 
     L_DUW=(CPMLDUW*100)/CPMMXUNW/CPMCPINT;
 
    Percent average logical channel data unit reads
    utillization for the partition:
 
     L_DUR=(CPMLDUR*100)/CPMMXUNR/CPMCPINT;
 
    Average total bytes written per second:
 
     WRITES=ROUND((CPMTDUW*CPMDUS)/CPMCPINT);
 
    Average total bytes read per second:
 
     READS=ROUND((CPMTDUR*CPMDUS)/CPMCPINT);
 
 USAGE CONSIDERATIONS:
 
    None

| F I C O N C H A N N E L L O A D A N A L Y S I S R E P O R T | Page 001 | | z/VM System ID SYSA Start 20JULyy:23:52:45.92 | | Release V5R4 End 20JULyy:23:59:45.92 | | CPMF: Extended Mode CSSID: 0 | |--------------------------------------------------------------------------------------------------------------------| | <------------------ FICON Channel Utilization % -----------------> | | <--------- Total for System ---------> <---- Own Partition -----> <--- Total Data ---> | |Channel Bus Work <- Data Units -> Work <- Data Units -> <-- Transfer Rate --> | |Path Cycle Units Write Read Units Write Read <---- (Bytes/s) ----> | |ID Shared T_Bcy T_WUn T_DUW T_DUR L_WUn L_DUW L_DUR Writes/s Reads/s | |0A YES 0 0 0 0 0 0 0 725 7085 | |0B YES 0 0 0 0 0 0 0 436 0 | |0C YES 0 0 0 0 0 0 0 284 0 | |0D YES 0 0 0 0 0 0 0 0 0 | |00 YES 0 0 0 0 0 0 0 0 1877 | |01 YES 0 0 0 0 0 0 0 52744 11940 | |02 YES 0 0 0 0 0 0 0 7957 10867 | |03 YES 0 0 0 0 0 0 0 0 1877 | |04 YES 0 0 0 0 0 0 0 0 1877 | |05 YES 0 0 0 0 0 0 0 0 0 | |06 YES 0 0 0 0 0 0 0 0 269 | |07 YES 0 0 0 0 0 0 0 0 0 | |08 YES 0 0 0 0 0 0 0 0 269 | |09 YES 0 0 0 0 0 0 0 0 1877 | |10 YES 0 0 0 0 0 0 0 0 1877 | |11 YES 0 0 0 0 0 0 0 0 1877 | |12 YES 0 0 0 0 0 0 0 0 1877 | |13 YES 0 1 0 0 0 0 0 100670 283112 | |14 YES 0 2 0 0 0 0 0 0 1876 | |15 YES 0 0 0 0 0 0 0 0 0 | |16 YES 0 0 0 0 0 0 0 0 0 | |17 YES 0 0 0 0 0 0 0 10 7245 | |18 YES 0 0 0 0 0 0 0 0 0 | |2A YES 0 0 0 0 0 0 0 0 0 | |2B YES 5 23 2 14 1 0 0 3323764 28138817 | |2C YES 0 0 0 0 0 0 0 0 0 | |2D YES 1 7 1 1 1 0 0 1522803 2455957 | |2E YES 0 0 0 0 0 0 0 0 27 | |20 YES 1 12 1 1 0 0 0 1441894 1462888 | |21 YES 1 7 1 0 0 0 0 2481329 524871 | |22 YES 1 7 1 0 0 0 0 2523201 498375 |

 

 
Figure 3-23.  VM FICON Channel Path Load Analysis