Previous Topic: Specify Data Access Options for a Stored ProcedureNext Topic: Specify Error Table Options


Define Teradata Tables

You can use the Teradata Table Editor to create new tables (entities) and to modify properties on existing tables in a Teradata physical model.

To define Teradata tables

  1. Click Tables on the Model menu.

    The Teradata Table Editor opens.

  2. Select a table and work with the following options:

    Note: Click New New icon in property editors to create a new object on the toolbar to create a new table. Use the Enter filter text text box to filter a very large list of tables to quickly locate the one you want to work with.

    Physical Name

    Specifies the physical name of the table. Change the physical name of the table in this field.

    Database

    Specifies the database or user to which the table belongs. Select the schema from the drop-down list.

    Teradata Type

    Specifies the type of the entity. Select from the drop-down list. Valid values are: Permanent, Global Temporary, Global Temporary Trace, or Queue Table.

    Physical Only

    Lets you specify whether the table should be suppressed from a logical model and appear in a physical model only.

    Generate

    Generates DDL for this object during Forward Engineering.

  3. Complete the following fields on the General tab:
    Checksum

    Defines the level of integrity checking for disk I/O. Select from the drop-down list. Valid values are: All, Default, Low, Medium, High, and None.

    Data Block Size Type

    Specifies the data block size type. Select from the drop-down list. Valid values are: Minimum, Maximum, or Specified.

    Data Block Size

    Specifies the data block size. Data can include Bytes or Kilobytes designation following the value.

    Fallback Protection

    Specifies the type of fallback protection for the database. Select from the drop-down.

    Free Space

    Specifies the amount of free space.

    Logging

    Specifies whether logging of changes to the data occurs.

    Row Control

    Specifies if duplicate rows are allowed in the table. Select from the drop-down list. Valid values are: Set or Multiset.

    Commit Type

    Specifies what happens to the data in a temporary or volatile table when the transaction completes. Select from the drop-down list. Valid values are: Delete or Preserve.

    Replication Group (Teradata 13 only)

    Specifies the name of the replication group to which the selected table is to be added. Select a replication group from the drop-down list or click New to open the Teradata Replication Group Editor.

    Has No Primary Index (Teradata 13 only)

    Specifies that the table has no primary index.

  4. Work with the other tabs in the editor to access additional design features, for example:
  5. (Optional) Click the Where Used tab to view where the table is used in the model.
  6. (Optional) Click the Comment tab and enter any comments you want associated with the table.
  7. (Optional) Click the UDP tab to work with user-defined properties for the table.
  8. (Optional) Click the Notes tab to view history information and view or edit user notes.
  9. Click Close.

    The Teradata Table Editor closes.

More information:

Define a Dimensional Modeling Role in a Property Editor

Define Data Movement Rules in a Property Editor

Specify Volumetric Information for a Table

Specify Journal Options for a Physical Object

Define Constraints that are Associated with the Table

Specify Error Table Options

Specify Statistics Options for a Teradata Table, Hash Index, or Join Index

Add Permissions in a Teradata Property Editor

Add a Comment in a Property Editor

Change the Object Creation Order in a Property Editor

Add a UDP in a Physical Property Editor

View History in a Property Editor

Define Data Movement Rules

You can use the Data Movement Rule tab to specify or view data movement rules on a table in a Teradata physical model.

Note: This tab displays only if the Data Movement option is selected for the model. To set the Data Movement option, right-click the Model on the Model Explorer, select Properties. Click the General tab and select the Data Movement check box under Modeling Features.

You can also use the Data Movement tab in the Teradata Table Editor to create a new data movement rule and apply it to a table.

To define a data movement rule for a Teradata table

  1. Click Tables on the Model menu. You can also right-click a table in the Model Explorer and select Properties.

    The Teradata Table Editor opens.

  2. Select the table you want to work with and click the Data Movement Rule tab.

    The Data Movement Rule tab opens.

  3. From the drop-down list, select data movement rules for the Refresh, Append, Backup, Recovery, Archive, and Purge rules.

    You can also click New New icon in property editors to create a new object to create new data movement rules using the Data Movement Rule editor.

  4. Click Close.

    The Teradata Table Editor closes.