Previous Topic: Changing the Status of the CA PMO/FDR InterfaceNext Topic: Including a New Private Library for Management


Including a Previously Excluded LNKLST Library

After you exclude a LNKLST library with the F PMO,EXCLLNK command or the EXCLLNK parameter, you can instruct CA PMO to start managing the library again. For instance, you might want to undo an exclusion if CA PMO can save elapsed time by managing the library.

Format

You undo an exclusion of LNKLST libraries with the following command:

F PMO {,INCLLNK=data set name}
      {,INCLLNK=ALL}

This command has the following operands:

PMO

The CA PMO keyword.

INCLLNK

You specify this operand as follows:

INCLLNK=data set name

Tells CA PMO to start managing the specified data set again.

INCLLNK=ALL

Tells CA PMO to start managing all excluded LNKLST libraries again.

Messages

After successfully executing this command, CA PMO responds:

PMO328I INCLLNK SUCCESSFUL FOR DSN=data set name LNKLST=linklistname

CA PMO continues to accumulate statistics for the specified library or libraries on the D4 monitor display. CA PMO does not reset the statistics obtained while a library was excluded from management.

If the specified library is already being managed by CA PMO, it responds:

PMO324I PMO IS NOT CURRENTLY EXCLUDING DSN=data set name

If you issue the command F PMO,INCLLNK=ALL, but CA PMO is already managing all LNKLST libraries, it responds:

PMO326I NO LNKLST LIBRARIES CURRENTLY EXCLUDED

If CA PMO cannot manage the library because you need to increase the value of the MLSIZE parameter, it responds:

PMO321I MLSIZE=0 - UNABLE TO INCLLNK DSN=data set name

If the library that you specify with this command is not in the LNKLST, CA PMO responds:

PMO322I PMO UNABLE TO INCLLNK DSN=data set name

If you receive message PMO322I, check the D4 PMOMON display for the correct names of LNKLST libraries.