As explained in the chapter "Using Parameters," you can control CA PMO through a number of parameters. The D0 display shows the current values of most CA PMO parameters. The following screen shows a sample D0 display:
PMO 4.4( Active ) Sys=IPOX 13NOV10:09:10:50 PMO Active Time= 5.500 hrs
D0 PMO Parameters Parameter Value Parameter Value MODE = Active SVCCPU = 103 FIX = YES EXCPCPU = 528 LLA = AUTO USERCOST = $ 20.00 OPERMSG = NO CPUCOST = $ 0.2839 REFDELAY = 00:01:00 EXCPCOST = $ 1.0000 CMDSECUR = YES MLSIZE = 300 RETNF = YES NUMCANDS = 50 CYCLE = 10 NUMADDED = 200 XSYSCOMM = PMO INTVL = 01:00:00 JES3ALLC = NO RESETPK = NO PANEXEC = NO SYSOUT = A TOPSECRT = NO DESIZE = 64 ROSCOE = NO EXCLREPT = NR DFDSS = YES FDR = YES CPU Serial Number = 012345 PMO is at Service Pack 5
The headings on the rows and columns of the D0 display are described in the following:
The name of the parameter.
The current value of the parameter. If you have not assigned a value, CA PMO assigns a default.
The serial number of the processor on which CA PMO runs.
The latest CA PMO service pack level on your system.
|
Copyright © 2011 CA.