Both primary commands and line commands are allowed on this panel.
If line command I or C, or primary command INS (abbreviation I) is entered, the Define Threshold Values panel is displayed.
APCBPP11 --- PMA - Define Absolute Alert Thresholds --------------------------- COMMAND ===> Job name : Job name or generic job name (using '*') '_' is a placeholder for one byte '*' is a generic value used at the end Examples: Job name Comment * all jobs (default) PRJ123* all jobs starting with PRJ123 P_J_2345 all jobs with two wild cards Elapsed time : 00:00 Minutes (format hh:mm) CPU time : 00:00:00 Minutes (format hh:mm:ss) EXCPs : 000000000 No. of EXCPs SRVUs : 000000000 No. of SRVUs total SRVUs CPU : 000000000 No. of SRVUs for CPU SRVUs SRB : 000000000 No. of SRVUs for SRB SRVUs I/O : 000000000 No. of SRVUs I/O SRVUs MSO : 000000000 No. of SRVUs MSO (Main Storage Occupancy) CANCEL: CAN OR PF3
Use this panel to define the job name or job name group and the corresponding thresholds.
If you want a value to be ignored for the threshold alert check, set zero as the parameter value.
|
Field Name |
Description |
|
Jobname |
Defines the name of the job for which alert thresholds are defined Generic notation is allowed by using wildcards _ and *. An underscore _ is a one character placeholder. An asterisk (*) is a placeholder for one or more characters at the end of a name. |
|
Elapsed |
Defines the alert threshold for elapsed time in the format hh:mm |
|
CPU Time |
Defines the alert threshold for CPU time in the format hh:mm:ss |
|
EXCPs |
Defines the alert threshold for EXCPs The maximum value is 999999999. |
|
SRVU TOTAL |
Defines the alert threshold for total service units The maximum value is 999999999. This value represents all four separate Service Units. |
|
SRVU CPU |
Defines the alert threshold for service units that are consumed only by CPU The maximum value is 999999999. |
|
SRVU SRB (Service Request Blocks) |
Defines the alert threshold for service units that are consumed only by SRB The maximum value is 999999999. |
|
SRVU I/O |
Defines the alert threshold for service units that are consumed only by I/O The maximum value is 999999999. |
|
SRVU MSO (Main Storage Occupancy) |
Defines the alert threshold for service units service units that are consumed only by main storage occupancy The maximum value is 999999999. Note: If one of the defined thresholds of the generic or fully qualified job is less than or equal to the corresponding value of the SMF values of that job, the Alert Handling of the Central Component generates a pending alert; see Alert Management. This alert results in a measurement request when the job executes the next time. |
|
Copyright © 2012 CA Technologies.