Previous Topic: Absolute Alert ThresholdsNext Topic: Search Mode


Defining Absolute Alert Thresholds

When you choose option TA on the Parameters Menu, the List Absolute Alert Thresholds panel is displayed. Use this panel to enter absolute alert threshold values to be examined by the alert handling function of PMA.

APCBPP10 --- PMA - List Absolute Alert Thresholds ----------------------------- COMMAND ===> SCROLL ===> HALF Search Mode : F ( F =First B =Best ) Commands : INS Insert CAN Cancel END Exit and Save Line Commands: I - Insert D - Delete C - Change ------------------------------------------------------------------------------- Time Service Units LC Jobname Elapsed CPU EXCPs Total CPU SRB (hh:mm) (hh:mm:ss) I/O MSO ------------------------------------------------------------------------------- ******************************* Bottom of data ********************************

The Central Component determines which jobs a threshold alert should be generated for by using the absolute alert thresholds.

The Central Component allows you to enter separate threshold consumption values for session time, CPU time, EXCPs and Service Units per job or group of jobs. Thresholds for each job or job group are represented by two detail lines on the bottom half of the panel. This area of the panel can be scrolled.