Previous Topic: Alert Log FilesNext Topic: Diagnostics for Investigator Statistics and Metric Panel


Diagnostics for Times Series

The Time Series Facility (TSF) is used as the back end for the following CA Chorus components:

Collect the JESMSGLG and LOG1 for the TSF Bridge Started Task (CHORTSFB).

JESMSGLG

Contains all initialization messages for TSF Bridge. If the TSF Bridge fails to initialize properly, you can find details here. Review all ETJTS prefixed messages and confirmation that the region is initialized by seeing the N00503 * TSF INITIALIZATION COMPLETE TSF * message.

The following message indicates the relevant port that has been assigned for use by the TSF Bridge. Ensure that this port is as expected and matches the specifications elsewhere (such as the CA Chorus Application Server ENVETJ and TSF PARM TSFPARMS):

ETJTS802I TSF server PDAPI socket registered on port 52393 token "TSF PD API: A " servlet=$TFPD10H
LOG1

Contains all application messages. Pay particular attention to messages indicating that the TSF data is being received from each of the products. The absence of recent data causes no data in the queries from Time Series, Investigator Statistics, and Metrics Panel. An example of the messages for a successful data feed follows:

FMTDUMP

TSF data not being available could be due to the CHORTSFB task not being active. If the TSF Bridge task has abended, obtain the formatted dump.

The CHORTSFB LOG1 dd generates messages each time a discipline sends data to the TSF. Verify that the data has been received recently for the discipline that you are investigating.