Report SVTRC190.A lists the physical volumes selected for input processing in VOLSER sequence by group specified. You can use this report as a pull list.
As Virtual Volumes age and the number of remaining retention days decrease, RECYCLE will change the Virtual Volumes subgroup assignment. The associated physical volumes will now contain Virtual Volumes for more than one subgroup. If RECYCLE is processing multiple subgroups for a group, these physical volumes will be mounted multiple times, once for each subgroup processed. The pull list VOLSER order reflects the first time a physical volume is mounted.
Report SVTRC190.A is broken into three sections as follows:
This section lists the physical Backstore Volumes selected for input processing and shows the mount order in which Recycle will mount and process the respective volumes. Subsequent mount requests for the same physical volume are not listed. When more than one subgroup is being Recycled and an input volume contains more than one subgroup then that volume will be mounted once for each subgroup.
When a group is rejected due to the TCR value, the group will not be processed. The volumes should not be loaded in manual tape cartridge loaders.
This section documents those groups which were skipped because the projected TCR was less than the requested TCR and the number of tapes that would have been released and written.
This section of the report documents the projected number of volumes that will be selected, released, and written.
Example of the SVTRC190.A report
RECYCLE.SVTRC190.A CA11.SVT2 CA VTAPE HH:MM:SS mm/dd/yy PAGE# 23 CA Vtape r11.5 SELECTED PHYSICAL INPUT VOLUME PULL LIST REPORT REPORTED BY FIRST VOLUME PROCESSING ORDER PHYSICAL --#PHYSICAL FILES-- GROUP VOLSER ACTIVE SELECTED ----- ------ ------------------- 61 540336 3 3 61 540476 3 3 61 540520 3 3 61 540562 3 3 61 540692 3 3 61 541202 5 5 61 541284 18 18 ------------------- 38 38 62 541085 2 2 62 541053 58 58 ------------------- 60 60 TOTAL --#PHYSICAL FILES-- ACTIVE SELECTED ------------------- 98 98 TAPE CONSOLIDATION RATIO EXCEPTION STATISITCS *** PROJECTED REJECTION REPORT *** REPORTED BY GROUP PROCESSING ORDER PROJECTED REQUESTED ------#PHYSICAL VOLUMES------ GROUP TCR TCR SELECTED RELEASED WRITTEN ----- ------- ------- ----------------------------- 62 (2:1) (3:1) 2 2 1 ----------------------------- TOTAL 2 2 1 TAPE CONSOLIDATION RATIO SELECTION SUMMARY RUNTIME PROJECTION STATISTICS REPORTED BY GROUP PROCESSING ORDER PROJECTED REQUESTED ------#PHYSICAL VOLUMES------ GROUP TCR TCR SELECTED RELEASED WRITTEN ----- ------- ------- ----------------------------- 61 (7:1) (5:1) 7 7 1 ----------------------------- TOTAL 7 7 1
|
Copyright © 2013 CA Technologies.
All rights reserved.
|
|