Previous Topic: Results for Recycled Virtual Volume FilesNext Topic: Physical Input Volume Status Report


Selected Physical Input Volume Pull List Report

Report SVTRC190.A lists the physical volumes selected for input processing in VOLSER sequence by group specified. You can use this report as a pull list.

As Virtual Volumes age and the number of remaining retention days decrease, RECYCLE will change the Virtual Volumes subgroup assignment. The associated physical volumes will now contain Virtual Volumes for more than one subgroup. If RECYCLE is processing multiple subgroups for a group, these physical volumes will be mounted multiple times, once for each subgroup processed. The pull list VOLSER order reflects the first time a physical volume is mounted.

Report SVTRC190.A is broken into three sections as follows:

Example of the SVTRC190.A report

RECYCLE.SVTRC190.A  CA11.SVT2                            CA VTAPE                        HH:MM:SS mm/dd/yy  PAGE#    23 CA Vtape r11.5                      SELECTED PHYSICAL INPUT VOLUME PULL LIST REPORT                                        REPORTED BY FIRST VOLUME PROCESSING ORDER       PHYSICAL  --#PHYSICAL FILES-- GROUP VOLSER     ACTIVE   SELECTED ----- ------    -------------------    61 540336          3          3    61 540476          3          3    61 540520          3          3    61 540562          3          3    61 540692          3          3    61 541202          5          5    61 541284         18         18                 -------------------                      38         38    62 541085          2          2    62 541053         58         58                 -------------------                      60         60        TOTAL    --#PHYSICAL FILES--                  ACTIVE   SELECTED                 -------------------                      98         98                                      TAPE CONSOLIDATION RATIO EXCEPTION STATISITCS                                            *** PROJECTED REJECTION REPORT ***                                            REPORTED BY GROUP PROCESSING ORDER         PROJECTED   REQUESTED   ------#PHYSICAL VOLUMES------ GROUP      TCR         TCR       SELECTED  RELEASED  WRITTEN -----    -------     -------    -----------------------------    62     (2:1)       (3:1)             2         2        1                                 -----------------------------                       TOTAL             2         2        1                                        TAPE CONSOLIDATION RATIO SELECTION SUMMARY                                              RUNTIME PROJECTION STATISTICS                                            REPORTED BY GROUP PROCESSING ORDER         PROJECTED   REQUESTED   ------#PHYSICAL VOLUMES------ GROUP      TCR         TCR       SELECTED  RELEASED  WRITTEN -----    -------     -------    -----------------------------    61     (7:1)       (5:1)             7         7        1                                 -----------------------------                       TOTAL             7         7        1