Several problems can occur when you try to vary the Virtual Devices online. Two of the most common are as follows:
IEE313I nnn UNIT REF. INVALID
Review the HCD definitions and correct the errors.
Also verify within IPCS. From option 6, issue the following command:
SETD ACTIVE
LISTUCB ucb
where ucb is the device address you are investigating.
In the UCBXPX at offset +0C, you find the SIDA and SCHNO fields. If the values in these fields are 0000s, then CA Vtape successfully allocates this address. If these fields contain anything other than 0000s, then you need to define another range.
CA Vtape uses this safety mechanism to ensure that no physical devices are associated with the UCB. After CA Vtape uses these devices, other resources can use the UCB only after the next IPL.
IEE025I UNIT nnn HAS NO LOGICAL PATHS
If you do not define enough Virtual Volumes, CA Vtape displays the SDSF SYSLOG Scratch Shortage message, as shown in the following example:

|