The CHANGE control statement changes various attributes of a SYSOUT group, including the archival date, that has already been archived to the CA View database.
You can use this statement if a SYSOUT was archived with inappropriate print attributes, or if the tape it was backed up to has been destroyed, and its internal status must be changed to NOT BACKED UP.
You can modify the following attributes with SARBCH CHANGE:
Specifies whether the SYSOUT has been backed up to tape from disk.
Contains a 20-byte user data field, typically accounting data.
Contains any user comments to be displayed with the SYSOUT in the CA View selection lists.
Syntax:
/CHANGE ADDRESS=('text'…)
ARCHDATE=mm/dd/yyyy
ARCHTIME=hh:mm:ss
BACKUP=OFF
BUILDING='text'
BURST=Y|N
CHARS=(xxxx xxxx xxxx xxxx)
CKPTLINE=nnnnn
CKPTPAGE=nnnnn
CKPTSEC=nnnnn
CLASS=x
COLORMAP=xxxxxxxx
COMPACT=xxxxxxxx
COMSETUP=xxxxxxxx
CONTROL=PROGRAM|SINGLE|DOUBLE|TRIPLE
COPIES=nnn
COPYG=(nnn nnn nnn nnn nnn nnn nnn nnn)
DATACK=BLOCK|UNBLOCK|BLKCHAR|BLKPOS
DEPT='text'
DEST=dest.userid
DPAGELBL=Y|N
DSK2VID=nnn
DUPLEX=NO|NORMAL|TUMBLE
FCB=xxxx
FLASH=(xxxx nnn)
FORM=xxxxxxxx
FORMDEF=xxxxxx
FORMLEN=nn[.mmm]IN|CM
FSSDATA='data'
GEN=nnnnn
ID=xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
INTRAY=nnn
IPDEST=ipdest
LINECT=nnn
MODIFY=(xxxx n)
NAME='text'
NOTIFY=(node.userid …)
OFFSETXB=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETXF=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETYB=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETYF=mmm[.nnn]IN|CM|MM|PELS|POINTS
OPTCDJ=Y|N
OUTBIN=nnnnn
OUTDISP=(ndisp,adisp)
OVERLAYB=xxxxxxxx
OVERLAYF=xxxxxxxx
OWNER=userid
PAGEDEF=xxxxxx
PGMRNAME=name
PIMSG=(Y|N,nnn)
PORTNO=nnnnn
PRMODE=xxxxxxxx
PRTERROR=DEFAULT|QUIT|HOLD
PRTOPTNS=xxxxxxxxxxxxxxxx
PRTQUEUE='queue'
PRTY=nnn
RESFMT=P240|P300
RESOURCE=xxxxxx
RETAINF=hhhh:mm:ss|FOREVER
RETAINS=hhhh:mm:ss|FOREVER
RETRYL=nnn
RETRYT=hhhh:mm:ss
ROOM='text'
SEQ=nnnnn
SYSAREA=Y|N
TAPECNT=nnnnn
THRESHOLD=nnnnnnnn
TITLE='text'
UCS=xxxx
USERDATA=('text' …)
USERFLD='text'
USERINFO='data'
USERLIB=(lib …)
WRITER=xxxxxxxx
where:
Specifies deliver address lines for the SYSOUT You can specify one to four deliver address lines containing up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.
Specifies the new archival date of the report.
Note:
A Subtype 35 (Archival Date Change) Metric SMF Record is created if the SMFTYPE Initialization Parameter is set to a valid SMF Record Type which enabled the Metrics Feature. This SMF record can be used as an Audit Trail to determine if report dates have been modified.
Specifies the new archival time of the report.
Note:
Specifies that the backup indicator for the SYSOUT is to be turned off.
The indicator is turned on when a SYSOUT is backed up. If a SYSOUT is backed up to tape, and that tape is lost or destroyed, you must specify BACKUP=OFF, to cause the CA View backup cycle to back up the SYSOUT again.
Specifies the building identification for the SYSOUT.
You can specify up to 60 text characters for building identification.
Specifies whether the paper is to be burst on the 3800 printer when printed.
Specifies a set of character arrangement table names for the 3800 printer for the SYSOUT.
You can specify a value of one to four names separated by one or more blanks and/or commas and enclosed in parentheses.
Specifies the maximum lines in a logical page. You can specify a range of 0 to 32767.
Specifies the number of logical pages before JES checkpoints data. You can specify a range of 1 to 32767.
Specifies the number of sections before JES checkpoints data. You can specify a range of 1 to 32767.
Specifies a class for the SYSOUT.
Specifies the color translation resource object.
Specifies the compaction table for sending SYSOUT to SNA terminal.
Specifies the microfiche setup resource.
Specifies line spacing.
Valid values are:
Each logical record contains a carriage control character.
Single spacing
Double spacing
Triple spacing
Specifies a number of copies to override the one used to print the SYSOUT. A range of 1 to 255 can be specified.
Specifies an optional set of copy groups for the 3800 printer to override those used to print the SYSOUT.
You can specify a range of one to eight copy groups separated by one or more blanks and/or commas and enclosed in parentheses. Each copy group value must be in the range of 1 to 255.
Specifies how printer errors are to be handled.
Valid values are:
Indicates errors are not reported.
Indicates errors are reported.
Indicates print errors are blocked.
Indicates data errors are blocked.
Indicates department identification for the SYSOUT. You can specify up to 60 text characters for department identification.
Specifies an optional destination and an optional user ID to override the one used to print the SYSOUT.
You can specify up to eight characters for destination and up to eight characters for the user ID. The destination can be a synonym created using the online DEFine DEVice command.
Specifies whether a security label is to be output.
Specifies the secondary disk version number. A range of 0 to 255 can be specified.
Specifies whether the report is printed on one or both sides of paper.
Valid values are:
Prints on one side only.
Rotates the physical page about the Y axis, which allows for binding the long side of the sheet.
Rotates the physical page about the X axis, which allows for binding the short side of the sheet.
Specifies an optional forms control image to override the one used to print the SYSOUT.
Specifies an optional forms flash overlay name and flash count for the 3800 printer to override those used to print the SYSOUT.
The forms flash overlay name and copy count are separated by one or more blanks and/or commas and are enclosed in parentheses.
Specifies an optional forms name to override the one used to print the SYSOUT.
Specifies a library member containing statements to control printing of the SYSOUT data on the 3800 printer
The statements can specify overlay forms, page location for overlays, and page format suppressions that can be activated.
Specifies the length and unit of measurement of the form.
Specifies Functional Subsystem data. You can specify up to 127 characters for functional subsystem data.
Specifies the absolute or relative number of the generation for which SYSOUT is affected by the CHANGE statement. If omitted, the most recently archived SYSOUT group for the ID is affected.
Specifies the SYSOUT ID of the group to be affected by the CHANGE statement.
You can specify 1 to 32 characters.
Note: If the id contains embedded blanks, commas, equal signs, parentheses, or quotes, it must be enclosed in quotes (single or double). Any quotes in Report-id must be entered as a pair of quotes because a non-paired quote ends the ID. For example, if the value is JIM’S REPORT, it must be entered as ‘JIM’’S REPORT’ or "JIM’S REPORT".
This parameter is required.
Specifies the printer input tray. A range of 1 to 255 can be specified.
Specifies the TCP/IP routing designation. You can specify up to 124 characters of TCP/IP routing information.
Specifies the maximum number of lines to be printed on each output page.
Specifies an optional copy modification module name and table reference character for the 3800 printer to override those used to print the SYSOUT.
The copy modification module name and table reference character are separated by one or more blanks and/or commas and are enclosed in parentheses. The table reference character can have a range of 0 to 3.
Specifies the name to print on output separator pages. You can specify up to 60 text characters for the name.
Specifies a print notification message destination. You can specify up to four destinations for the print notification message.
Specifies an X offset of logical page origin for the back side of paper.
Specifies an X offset of logical page origin for the front side of paper.
Specifies a Y offset of logical page origin for the back side of paper.
Specifies a Y offset of logical page origin for the front side of paper.
Specifies an optional override as to whether the SYSOUT records contain table reference characters for the 3800 printer. Valid values are Y or N.
Specifies output bin ID. You can specify a range of 1 to 65535.
Specifies the normal and abnormal output disposition.
Valid values are:
Indicates SYSOUT is not printed until it is released.
Indicates SYSOUT is printed but not immediately purged.
Indicates SYSOUT is not printed until it is released and not immediately purged once it is printed.
Indicates SYSOUT is deleted without printing.
Indicates SYSOUT is printed and purged.
Specifies medium overlay for the back side of paper.
Specifies medium overlay for the front side of paper.
Specifies the user ID that created the report.
Specifies a library member containing statements to control printing of the SYSOUT data on the 3800 printer.
The statements can specify logical page length, width, fonts, and page segments.
Specifies the programmer name.
Specifies whether messages from a functional subsystem are to be printed and the message threshold at which the system is to cancel printing.
Specifies TCP port number at which FSS connects to the printer. A range of 1 to 65535 can be specified.
Specifies the process mode required for printing the SYSOUT group.
Specifies an action for print error.
Valid values are:
Indicates a standard action is taken when a terminating error occurs during printing
Indicates the SYSOUT is released when a terminating error occurs during printing
Indicates the SYSOUT is placed in held status when a terminating error occurs during printing
Specifies named entity of print options for FSS.
Specifies a target print queue for FSS. You can specify up to 127 characters for print queue.
Specifies the resolution used to format the print.
Valid values are:
P240
Indicates 240 pels per inch resolution
Indicates 300 pels per inch resolution
Specifies the name of an AFP RESOURCE rather than a Report ID.
Do not specify ID= when using the RESOURCE parameter.
This parameter along with the BACKUP=OFF parameter allow an AFP resource to be recreated on tape. This type of control statement is generated through SARTSLST.
Specifies the failed transmission retain time.
Specifies the successful transmission retain time
Specifies the maximum number of transmission retries
Specifies the length of time to wait between retries
Specifies a room identification. You can specify up to 60 text characters for room identification.
Specifies the absolute or relative SYSOUT sequence number of the SYSOUT group to be affected by the CHANGE statement
The second most recently archived SYSOUT is processed regardless of its generation and sequence number.
The third most recently archived SYSOUT is processed regardless of its generation and sequence number.
Specifies whether the system is to reserve a system area on each page of output
Specifies the number of tapes that the SYSOUT resides on. A range of 1 to 9999 can be specified.
Specifies the maximum size of a SYSOUT data set. A range of 1 to 99999999 can be specified.
Specifies a title identification. You can specify up to 60 text characters for title identification.
Specifies an optional special character set name to override the one used to print the SYSOUT
Specifies user data for the SYSOUT
You can specify 1 to 16 user data lines containing up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.
Specifies user comments to be displayed with this SYSOUT on the CA View selection lists
To include any spaces within the comment, enclose the entire comment in quotes, as in USERFLD='THIS IS MY COMMENT'.
Specifies up to 20 characters of user information (typically accounting data)
Specifies up to eight libraries containing APF resources
Specifies an external writer name.
Default:
If you specify a parameter without a value, that parameter is set to blanks. For example, if you specify the following, the PAGEDEF field is set to blanks:
PAGEDEF=
|
Copyright © 2015 CA Technologies.