Be sure the specified or default configuration file resides on an accessed minidisk, because VMTSTF reads the configuration file to obtain information from the STAM, STAMPARM, and CMSTMC records.
Be sure both the STAM and STAMPARM records are present in the configuration file. Use VMTSTF only with the CMS or DISK parameters of the STAM configuration file record.
If the number of systems, the number of devices, or the addresses of devices controlled by STAM are changed, reformat the STAM control file.
Do not run the utility while STAM is active on a participating system; this causes STAM to stop on all systems.
If the 370 Accommodation Feature is off, the utility will automatically set it on. The utility will set the feature off again when it has completed running.