Previous Topic: Step 7: Modify the PRODUCT CONFIG FileNext Topic: Post–Installation Recommendations


Step 8: Re–IPL Using the New CP Component

You need to re-IPL the system to invoke the new CP nucleus.

To re-IPL using new CP nucleus

  1. Shut down and re–IPL your system.
  2. Log on to VMSECURE. Type IPL CMS. Type YES to initialize. The Rules Facility is now installed.
  3. Test the facility. From VMANAGER, verify the CP component configuration, using the QCPCFG command:
    vmsecure qcpcfg
    

    Output similar to the following displays:

    AVAILCHK	4  2
    WAITCHK	30	15
    VMXTRAP	DIAL
    ACITRACE	ON	63
    CPACTION	*		ACCEPT
    CPACTION	OPERATOR	ACCEPT
    CPACTION	AUTOLOG1	ACCEPT	NOPASS
    CPACTION	VMSECURE	ACCEPT
    CPACTION	VMBATCH	ACCEPT
    CPACTION	VMBACKUP	ACCEPT
    CPACTION	MAINT		ACCEPT
    CPACTION	VMANAGER	ACCEPT
    CPACTION	VMBAT001	WAIT
    CPACTION	VMBAT002	WAIT
    CPACTION	VMBAT003	WAIT
    

    When you are finished testing, continue to Post–Installation Recommendations.