Create a Threshold Monitor
Create a threshold monitor that lets the agent monitor the servers or the server groups against specified thresholds. The agent sends a trap when thresholds are breached.
Follow these steps:
The Template List page appears.
The Summary page for the template appears.
The Summary page appears with a list of monitors managed by the policy.
The Threshold Monitors page appears.
The Threshold Monitor Details: New dialog appears.
Defines the table index that you want to use.
Specifies the platform.
Defines an optional description.
Specifies the object class to monitor. The values refer to the available MIB tables.
Defines the object class name to use for the object state model. Value is an arbitrary string, for example, FileSystems.
Specifies the object attribute to monitor. The values refer to the available attributes of the table selected as Object Class. The attribute (for example, devCapacity = 1.3.6.1.4.1.546.1.1.1.7.1.14) specifies the initial part of the MIB object (OID) to monitor with this threshold monitor.
Defines the object attribute name to use for the object state model. This is an arbitrary string, for example, PercentUsed.
Specifies the object instance to monitor. This value, for example, .3 to monitor the third row in the device table (devTable) specifies the index part of the MIB object (OID) to monitor with this threshold monitor. For some object classes, the name of the instance itself can be given (for example, C: instead of .3, or /var for a Unix machine).
Defines the object instance name to use for the object state model. Value is an arbitrary string, for example, SysVol_C.
Defines the evaluation interval for the monitor in a multiple of 30 seconds.
The Threshold Configuration page lets you define the following settings:
Specifies the severity to use for the object state model.
Specifies the operator to use.
Defines the value to use.
Specifies the sample type to use.
The Maintenance Window page lets you define the following settings:
Specifies if the monitor maintenance entry is active or inactive.
Defines the start time when the monitor is switched off and the maintenance window begins.
Defines the stop time when the monitor is switched on again and the maintenance window ends.
The Optional Settings subtab lets you define the flags that can be used for the different monitor entries or history control entries.
The Threshold Monitor settings are saved.
The Threshold Monitor is loaded to the template.