There are two methods in which CA OPS/MVS can send commands to CA 7 WA. Following is a description of these two methods:
This method allows for a two-way interface where a CA OPS/MVS OPS/REXX program can issue a command to CA 7 WA and receive the command responses. Perform the following steps to implement this type of command interface:
ADDRESS CA7 CAL2X2WR 15 DETACH TYPE 0
After all of the above requirements have been met, you can issue and receive command responses from an ADDRESS CA7 host REXX statement coded within CA OPS/MVS OPS/REXX programs. For an example of this, see member ADDRCA7 in the hlq.CCLXSAMP data set that is created during CA OPS/MVS installation.
This method uses the U7SVC routine to issue commands from CA OPS/MVS to CA 7 WA. With this method, command responses are not returned to the issuing CA OPS/MVS OPS/REXX rule or OPS/REXX program. No additional installation requirements are needed to use this method.
For more information on the OPSCA7 function, see the Command and Function Reference.