6. DATA SOURCES › 6.2 VTS Component Data Sources › 6.2.4 IBM Hydra Bulk Volume Information Retrieval (BVIR)
6.2.4 IBM Hydra Bulk Volume Information Retrieval (BVIR)
With the new generation of IBM virtual tape servers--the
TS77xx series--the statistics are no longer sent to the
attached hosts as SMF records. They are written to an
internal database within the TS77xx itself. Both
point-in-time and historical records are stored.
Point-in-time records contain the operations activity over
the last 15 seconds for real-time dashboard reporting at the
device itself. Historical records contain the operational
statistics at 15-minute intervals and are stored for 90 days.
The CA MICS Tape Analyzer Option processes the historical
records. The historical data is obtained by a BVIR request
to the server to extract the data.
The following sections describe the historical record and
strategies for collecting the data.
1 - IBM TS7700 BVIR Record Description
2 - Collecting Historical BVIR Records
Copyright © 2014 CA.