

3. TABULAR REPORTS, GRAPHS, AND MICF INQUIRIES › 3.1 Tabular Reports › 3.1.3 Tabular Report Descriptions › 3.1.3.2 Workload Analysis Reports › 3.1.3.2.8 NLDM Workload by Terminal (SNT214)
3.1.3.2.8 NLDM Workload by Terminal (SNT214)
INTENDED USAGE:
Use this display to quantify the workload volume imposed
on the network by the devices attached to a given
terminal. You can monitor this report for indications
that the maximum supportable utilization level of the
terminal is being reached.
FORMAT:
This display indicates the character and path information
unit (PIU) throughput for selected terminals. You can
see a sample display of the profile report in Figure 3-22.
DATABASE FILE: NVSNSA
DATA ELEMENTS USED:
NETWRKID SYSID SLULINK ZONE NSANRCBR NSANRCBS
NSANRTBS NSANRTBR NSANRCPR NSANRCPS NSANRTPS NSANRTPR
NSATRESC
CALCULATIONS:
PER_MIN = (ENDTS - STARTTS) / 60
TOTAL CONTROL BYTES / MIN = SUM(NSANRCBR,NSANRCBS)
CONTROL BYTES SENT / MIN = NSANRCBS / PER_MIN
CONTROL BYTES RECEIVED / MIN = NSANRCBR / PER_MIN
TOTAL TEXT BYTES / MIN = SUM(NSANRTBS,NSANRTBR)
TEXT BYTES SENT / MIN = NSANRTBS / PER_MIN
TEXT BYTES RECEIVED / MIN = NSANRTBR / PER_MIN
TOTAL BYTES / MIN =SUM(NSANRCBR,NSANRCBS,NSANRTBS,NSANRTBR)
/ PER_MIN
TOTAL BYTES SENT / MIN = SUM(NSANRCBS,NSANRTBS) / PER_MIN
TOTAL BYTES RECEIVED / MIN = SUM(NSANRCBR,NSANRTBR)
TOTAL CONTROL PIUS / MIN = SUM(NSANRCPR,NSANRCPS)
CONTROL PIUS SENT / MIN = NSANRCPS / PER_MIN
CONTROL PIUS RECEIVED / MIN = NSANRCPR / PER_MIN
TOTAL TEXT PIUS / MIN = SUM(NSANRTPS,NSANRTPR)
TEXT PIUS SENT / MIN = NSANRTPS / PER_MIN
TEXT PIUS RECEIVED / MIN = NSANRTPR / PER_MIN
TOTAL PIUS / MIN = SUM(NSANRCPR,NSANRCPS,NSANRTPS,NSANRTPR)
/ PER_MIN
TOTAL PIUS SENT / MIN = SUM(NSANRCPS,NSANRTPS) / PER_MIN
TOTAL PIUS RECEIVED / MIN = SUM(NSANRCPR,NSANRTPR)
/ PER_MIN
TOTAL BYTES TRANSMITTED =
SUM(NSANRTBR,NSANRTBS,NSANRCBR,NSANRCBS)
CONTROL BYTES TRANSMITTED = SUM(NSANRCBR,NSANRCBS)
TEXT BYTES TRANSMITTED = SUM(NSANRTBR,NSANRTBS)
TOTAL PIUS TRANSMITTED =
SUM(NSANRTPR,NSANRTPS,NSANRCPR,NSANRCPS)
CONTROL PIUS TRANSMITTED = SUM(NSANRCPR,NSANRCPS)
TEXT PIUS TRANSMITTED = SUM(NSANRTPR,NSANRTPS)
AVERAGE BYTES PER CONTROL PIU SENT = NSANRCBS / NSANRCPS
AVERAGE BYTES PER CONTROL PIU REC'D = NSANRCBR / NSANRCPR
AVERAGE BYTES PER TEXT PIU SENT = NSANRTBS / NSANRTPS
AVERAGE BYTES PER TEXT PIU REC'D = NSANRTBR / NSANRTPR
USAGE CONSIDERATIONS:
You can report on a different number of terminals by
changing the value of the %SL214 macro in
prefix.MICS.USER.SOURCE(#SNTRPTS). The default macro
selects all SLUs.
CA MICS NETWORK COMPONENT
(SNT214) NLDM WORKLOAD BY TERMINAL (SLU) : VTAA9
NETWORK: NETWORK1 SYSTEM: TSO2
PRODUCED: AUGUST 7, 2003 ZONE: WEEKENDS
+-------------------------------------------------+
| | |
| ACTIVITY INDICATORS | 08/05/03 |
| | |
|---------------------------------+---------------+
| THROUGHPUT DATA | |
| | |
| TOTAL CONTROL BYTES / MIN | 0.09 |
| CTRL BYTES SENT / MIN | 0.08 |
| CTRL BYTES RECEIVED / MIN | 0.01 |
| TOTAL TEXT BYTES / MIN | 149.84 |
| TEXT BYTES SENT / MIN | 148.35 |
| TEXT BYTES RECEIVED / MIN | 1.49 |
| TOTAL BYTES / MIN | 149.92 |
| TOTAL BYTES SENT / MIN | 148.42 |
| TOTAL BYTES RECEIVED / MIN | 1.50 |
| | |
| TOTAL CTRL PIUS / MIN | 0.03 |
| CTRL PIUS SENT / MIN | 0.01 |
| CTRL PIUS RECEIVED / MIN | 0.01 |
| TOTAL TEXT PIUS / MIN | 0.37 |
| TEXT PIUS SENT / MIN | 0.19 |
| TEXT PIUS RECEIVED / MIN | 0.18 |
| TOTAL PIUS / MIN | 0.39 |
| TOTAL PIUS SENT / MIN | 0.20 |
| TOTAL PIUS RECEIVED / MIN | 0.19 |
| | |
| | |
| WORKLOAD STATISTICS | |
| | |
| TOTAL BYTES TRANSMITTED | 173,085 |
| CTRL BYTES TRANSMITTED | 103 |
| TEXT BYTES TRANSMITTED | 172,982 |
| TOTAL PIUS TRANSMITTED | 456 |
| CTRL PIUS TRANSMITTED | 30 |
| TEXT PIUS TRANSMITTED | 426 |
| | |
| | |
| AVG BYTES PER CNTL PIU SENT | 5.75 |
| AVG BYTES PER CNTL PIU REC'D | 0.79 |
| AVG BYTES PER TEXT PIU SENT | 792.88 |
| AVG BYTES PER TEXT PIU REC'D | 8.19 |
| | |
+-------------------------------------------------+
Figure 3-22. NLDM Workload by Terminal (Profile)
Copyright © 2014 CA.
All rights reserved.
 
|
|