3. TABULAR REPORTS, GRAPHS, AND MICF INQUIRIES › 3.1 Tabular Reports › 3.1.3 Tabular Report Descriptions › 3.1.3.2 Workload Analysis Reports › 3.1.3.2.7 NLDM Workload by Control Unit (SNT213)
3.1.3.2.7 NLDM Workload by Control Unit (SNT213)
INTENDED USAGE:
Use this display to quantify the workload volume for each
monitored terminal controller (physical unit). You can
monitor this report for indications that the maximum
supportable utilization level is being reached.
The job that produces this display will not execute or
will cause unpredictable results unless both the value and
the label for account code SNTACT3 is set to SLUPU for
NetView/NLDM or CA NetMaster data. For information on how
to define account codes, see Section 7.2.
FORMAT:
This display indicates the character and path information
unit (PIU) throughput of selected control units. You can
see a sample display of the profile report in Figure 3-21.
DATABASE FILE: NVSNSA
DATA ELEMENTS USED:
NETWRKID SYSID SLULINK ZONE NSANRCBR NSANRCBS
NSANRTBS NSANRTBR NSANRCPR NSANRCPS NSANRTPS NSANRTPR
NSATRESC
CALCULATIONS:
PER_MIN = (ENDTS - STARTTS) / 60
TOTAL CONTROL BYTES / MIN = SUM(NSANRCBR,NSANRCBS)
CONTROL BYTES SENT / MIN = NSANRCBS / PER_MIN
CONTROL BYTES RECEIVED / MIN = NSANRCBR / PER_MIN
TOTAL TEXT BYTES / MIN = SUM(NSANRTBS,NSANRTBR)
TEXT BYTES SENT / MIN = NSANRTBS / PER_MIN
TEXT BYTES RECEIVED / MIN = NSANRTBR / PER_MIN
TOTAL BYTES / MIN =SUM(NSANRCBR,NSANRCBS,NSANRTBS,NSANRTBR)
/ PER_MIN
TOTAL BYTES SENT / MIN = SUM(NSANRCBS,NSANRTBS) / PER_MIN
TOTAL BYTES RECEIVED / MIN = SUM(NSANRCBR,NSANRTBR)
TOTAL CONTROL PIUS / MIN = SUM(NSANRCPR,NSANRCPS)
CONTROL PIUS SENT / MIN = NSANRCPS / PER_MIN
CONTROL PIUS RECEIVED / MIN = NSANRCPR / PER_MIN
TOTAL TEXT PIUS / MIN = SUM(NSANRTPS,NSANRTPR)
TEXT PIUS SENT / MIN = NSANRTPS / PER_MIN
TEXT PIUS RECEIVED / MIN = NSANRTPR / PER_MIN
TOTAL PIUS / MIN = SUM(NSANRCPR,NSANRCPS,NSANRTPS,NSANRTPR)
/ PER_MIN
TOTAL PIUS SENT / MIN = SUM(NSANRCPS,NSANRTPS) / PER_MIN
TOTAL PIUS RECEIVED / MIN = SUM(NSANRCPR,NSANRTPR)
/ PER_MIN
TOTAL BYTES TRANSMITTED =
SUM(NSANRTBR,NSANRTBS,NSANRCBR,NSANRCBS)
CONTROL BYTES TRANSMITTED = SUM(NSANRCBR,NSANRCBS)
TEXT BYTES TRANSMITTED = SUM(NSANRTBR,NSANRTBS)
TOTAL PIUS TRANSMITTED =
SUM(NSANRTPR,NSANRTPS,NSANRCPR,NSANRCPS)
CONTROL PIUS TRANSMITTED = SUM(NSANRCPR,NSANRCPS)
TEXT PIUS TRANSMITTED = SUM(NSANRTPR,NSANRTPS)
AVERAGE BYTES PER CONTROL PIU SENT = NSANRCBS / NSANRCPS
AVERAGE BYTES PER CONTROL PIU REC'D = NSANRCBR / NSANRCPR
AVERAGE BYTES PER TEXT PIU SENT = NSANRTBS / NSANRTPS
AVERAGE BYTES PER TEXT PIU REC'D = NSANRTBR / NSANRTPR
USAGE CONSIDERATIONS:
You can report on various number of control units by
changing the value of the %SL213 macro in
prefix.MICS.USER.SOURCE(#SNTRPTS). The default macro
selects all control units.
CA MICS NETWORK COMPONENT
(SNT213) NLDM WORKLOAD BY CONTROL UNIT (SLUPU): P09972
NETWORK: NETWORK1 SYSTEM: TSO2
PRODUCED: AUGUST 7, 2003 ZONE: PRIME TIME
+-------------------------------------------------+
| | |
| ACTIVITY INDICATORS | 08/01/03 |
| | |
|---------------------------------+---------------+
| THROUGHPUT DATA | |
| | |
| TOTAL CONTROL BYTES / MIN | 1.38 |
| CTRL BYTES SENT / MIN | 0.96 |
| CTRL BYTES RECEIVED / MIN | 0.42 |
| TOTAL TEXT BYTES / MIN | 518.00 |
| TEXT BYTES SENT / MIN | 421.36 |
| TEXT BYTES RECEIVED / MIN | 96.64 |
| TOTAL BYTES / MIN | 519.38 |
| TOTAL BYTES SENT / MIN | 422.32 |
| TOTAL BYTES RECEIVED / MIN | 97.06 |
| | |
| TOTAL CTRL PIUS / MIN | 0.69 |
| CTRL PIUS SENT / MIN | 0.18 |
| CTRL PIUS RECEIVED / MIN | 0.52 |
| TOTAL TEXT PIUS / MIN | 1.59 |
| TEXT PIUS SENT / MIN | 0.73 |
| TEXT PIUS RECEIVED / MIN | 0.85 |
| TOTAL PIUS / MIN | 2.28 |
| TOTAL PIUS SENT / MIN | 0.91 |
| TOTAL PIUS RECEIVED / MIN | 1.37 |
| | |
| | |
| WORKLOAD STATISTICS | |
| | |
| TOTAL BYTES TRANSMITTED | 5,355,218 |
| CTRL BYTES TRANSMITTED | 14,206 |
| TEXT BYTES TRANSMITTED | 5,341,012 |
| TOTAL PIUS TRANSMITTED | 23,532 |
| CTRL PIUS TRANSMITTED | 7,164 |
| TEXT PIUS TRANSMITTED | 16,368 |
| | |
| | |
| AVG BYTES PER CNTL PIU SENT | 5.38 |
| AVG BYTES PER CNTL PIU REC'D | 0.81 |
| AVG BYTES PER TEXT PIU SENT | 574.99 |
| AVG BYTES PER TEXT PIU REC'D | 113.07 |
| | |
+-------------------------------------------------+
Figure 3-21. NLDM Workload by Control Unit (Profile)