Previous Topic: SNT00337Next Topic: SNT00339


SNT00338

+-----------------+
| S N T 0 0 3 3 8 |
+-----------------+

TEXT:        PREVIOUS DATA SOURCE STATEMENT CONTAINED NTCP
             OPTION THAT MUST BE FOLLOWED BY NETTCP SMF = NNN
             STATEMENT. PLEASE CODE THE MISSING STATEMENT
             BEFORE THIS STATEMENT: %LINE

TYPE:        Error

REASON:      The NETTCP SMF = nnn is not coded to declare the
             SMF record number for the NTCP data source that
             is used in the DATA SOURCE statement that
             preceded it.

ACTION:      Edit prefix.MICS.PARMS(SNTOPS) and specify
             NETTCP SMF = nnn before the statement given in
             the message text referenced above, or remove the
             NTCP option from the preceding DATA SOURCE
             statement.

             Resubmit the prefix.MICS.CNTL(SNTPGEN).

REFERENCES:  Chapter 7 of this guide