Previous Topic: 4.9.1 Prerequisites

Next Topic: 4.9.3 Application Specific Alerts

4.9.2 CA MICS Abend Reporting


CA MICS Abend Reporting produces Service Desk call tickets
when CA MICS operational jobs (that is, Daily and Monthly)
end with any of the following user abend codes:


   User
Abend Code   Termination Condition/Reason
----------   ------------------------------------------------

     100     Database marked non-updatable.

     101     Database marked non-updatable; aging in
             progress when failure occurred.

     110     Internal step restart failed; required files
             are missing or corrupted.

     120     Internal step restart failed; saved work files
             missing or corrupted.

     130     Stand-alone AUDIT, HISTW, and/or HISTM archive
             tape processing job not yet executed.

     300     Input data file was empty.

     310     The original system identifier in the input data
             was not defined in the SYSID parameter when the
             last run of ALLPGEN or BASPGEN occurred.

     320     Zone was not defined in ZONE parameter when the
             last ALLPGEN or BASPGEN job was run.

     400     Invalid checkpoint record encountered.

     410     Limit of ORGSYSID/COMPONENT entries is exceeded
             in the Checkpoint File.

     420     Invalid FORCE or SELECT range was specified.

     430     INPUTRDR end-of-file routine was not entered
             after the last input record.

     440     SAS version is not compatible with CA MICS
             version.

     450     PREFIX in the Checkpoint File does not match the
             PREFIX used in the update procedure.

   User
Abend Code   Termination Condition/Reason
----------   ------------------------------------------------

     460     Checkpoint File initialization failed or the
             checkpoint routine initial update processing
             failed.

     470     Exit did not return control properly.

     500     Execution date less than previous date.

     510     YEAR is not in the range of years defined to
             CA MICS.


To activate this feature, the SD_ACTIVE keyword must be set
to YES in prefix.MICS.PARMS(EXECDEF).  See Section 2.3.5 for
more information on setting EXECDEF options.