The system generation compiler updates the data dictionary as it processes the syntax that you submit. In the event that either the compiler or the DC/UCF system terminates abnormally during an online compiler session, updates already made to the data dictionary are unaffected.
After a Compiler Abend
After a compiler abend, you can resume the abended session after recovery has occurred. When you enter the task code to invoke the compiler, the online session resumes with the processing options that were in effect before the abend and the current work file intact.
After a DC/UCF System Abend
After a DC/UCF system abend, the work file and all session options are lost. When you enter the task code to invoke the compiler, the compiler initiates a new online session.
Note: If the system terminates while an online session is suspended, the work file and all session options are lost.
|