Previous Topic: Storage Detail (PF13)Next Topic: Line IO History


Line I/O Detail (PF14)

PM-Rnn.n SYSTEM71 CA, Inc. V71 08.348 11:43:47.66 CMD--> Window : 02 02 08:30 LIDT Line I/O Detail > Line Line Line PTERMs Read Read Write Write Name Type Status Defined Total Errors Total Errors UCFLINE UCF LINE DRIVER IN-SERVICE 4 0 0 0 0 CCILINE DDS VTAM IN-SERVICE 20 0 0 0 0 CONSOLE2 OPERATOR CONSOLE IN-SERVICE 1 0 0 0 0 VTAM VTAM INTERFACE IN-SERVICE 110 44706 0 44707 0 VTAM92 VTAM INTERFACE CLOSED 0 0 0 0 0

PM-Rnn.n SYSTEM71 CA, Inc. V71 08.348 11:43:47.66 CMD--> Window : 02 02 08:30 LIDT Line I/O Detail < > Line Write PTE_RPL PTE_RPL Read Read Write Write RPL Name Errors Requests Waits Waits Time Waits Time Waits UCFLINE 0 0 0 0 .0000S 0 .0000S 0 CCILINE 0 0 0 0 .0000S 0 .0000S 0 CONSOLE2 0 0 0 0 .0000S 0 .0000S 0 VTAM 0 89538 32797 92 1.03S 29412 2:07M 0 VTAM92 0 0 0 0 .0000S 0 .0000S 0

PM-Rnn.n SYSTEM71 CA, Inc. V71 08.348 11:43:47.66 CMD--> Window : 02 02 08:30 LIDT Line I/O Detail < Line PTE_RPL PTE_RPL Read Read Write Write RPL RPL Name Requests Waits Waits Time Waits Time Waits Time UCFLINE 0 0 0 .0000S 0 .0000S 0 .0000S CCILINE 0 0 0 .0000S 0 .0000S 0 .0000S CONSOLE2 0 0 0 .0000S 0 .0000S 0 .0000S VTAM 89538 32797 92 1.03S 29412 2:07M 0 .0000S VTAM92 0 0 0 .0000S 0 .0000S 0 .0000S

Screen Description

The Line IO Detail screen displays detailed information about each teleprocessing (TP) line defined in the DC/UCF network for the current interval. For each line, the screen indicates the status and displays access statistics related to line use.

Line Types

The following table lists the TP line types defined at system generation. For each line type, the equivalent TYPE parameter specification for the system generation LINE statement is included.

Line Type

TYPE Parameter

Meaning

Console

CONSOLE

Operator's console

CCI

CCI

CCI line driver

SNA

VTAMLU

VTAM/SNA logical units

UCF

UCFLINE

UCF line driver

Start/Stop

ASYNC

Start/Stop terminals

SYSOUT only

SYSOUTL

SYSOUT only (for printers)

VTAM

VTAMLIN

VTAM interface

Local 3270

L3270B

Local 3270s

Remote 3270

BSC3

Remote 3270s

Simulated 3270

S3270Q

Simulated 3270s

Online Sim 3270

S3270Q

Online simulated 3270s

L3280 Printer

L3280B

Local 3280 printer

TCAM

TCAMLIN

TCAM driver

BSC Non-Sw P-P

BSC2

BSC nonswitched point-to-point

BSC Switch P-P

BSC2

BSC switched point-to-point

BSC Multipoint

BSC3

BSC multipoint

DCAM

DCAMLIN

DCAM interface

SOCKET

SOCKET

SOCKET line driver

Line Status

The following statuses can be indicated for a TP line:

Status

Meaning

IN-SERVICE

Line is in service

OUT-SERVICE

Line is out of service

CLOSED

Line has not been opened

Using This Screen

To request the Line IO History screen, press [PF9].

What To Look For