PM-Rnn.n SYSTEM71 CA, Inc. V71 08.348 16:09:53.37 CMD--> Window : 02 02 15:30 STDT Storage Detail > Storage Pool Pool In Short On High Storage Storage Storage Pool Size(Kb) Use(Kb) Storage Water(Kb) Cushion(Kb) Gets Frees 0 1016kB 28672 0 40960 28672 115 88 30 1000kB 104kB 0 144kB 4096 197 182 200 2000kB 0 0 4096 4096 1 1 201 2000kB 40960 0 45056 4096 27 1 202 4000kB 516kB 0 528kB 4096 300 193 255 1500kB 476kB 0 484kB 0 236 138
PM-Rnn.n SYSTEM71 CA, Inc. V71 08.348 16:09:53.37 CMD--> Window : 02 02 15:30 STDT Storage Detail < Storage High Storage Storage Storage Storage Storage Storage Pool Water(Kb) Cushion(Kb) Gets Frees Pass 1 Pass 2 Pass 3 0 40960 28672 115 88 96 5 0 30 144kB 4096 197 182 130 6 0 200 4096 4096 1 1 0 0 0 201 45056 4096 27 1 18 8 0 202 528kB 4096 300 193 0 0 0 255 484kB 0 236 138 0 0 0
Screen Description
The Storage Detail screen displays statistics related to the use of system storage pools for the current interval. The screen includes one line for each storage pool defined to the DC/UCF system at system generation. For each storage pool, the screen identifies the pool size and provides access statistics.
What To Look For
Storage-use problems are indicated by the Short On Storage field. A non-zero number should represent peak use, not a chronic condition. If the field is always 0, you may have allocated too much pool space.
To alleviate a storage-use problem, you should take the following steps:
|
Copyright © 2014 CA.
All rights reserved.
|
|