Verified by Debugger
Program breakpoints, established with the AT command, must be set at addresses that contain valid instructions or valid command elements (CMEs for CA ADS dialogs). If the address cannot be validated, the debugger displays a message to indicate that the breakpoint could not be set. A verifying message is displayed when the address is valid.
Note: The debugger checks for a valid operation code at each breakpoint that is set; you are responsible for placing the breakpoint at an actual instruction. If a breakpoint address resolves to an address offset that contains a valid operation code but does not contain a valid instruction, the program could be altered with unpredictable results.
|
Copyright © 2013 CA.