Previous Topic: VSE/ESA File Processing Alternate MethodNext Topic: Return Codes


Message Text

AUDT001I STEP: step-name, STARTED

Reason:

The reorganization step indicated began executing.

Action:

None.

AUDT002I STEP: step-name, ENDED, CC=n

Reason:

The reorganization step that has just ended and its return code.

Action:

None.

AUDT003I CURRENT STEP: step-name, IN SUBSTEP substep-name, DURhh.mm.ss

Reason:

The current reorganization step being processed, the substep it is in, and the amount of time it has been there.

Action:

None.

AUDT004I AREA: area-name,PAGE RANGE=nnnnnnnnnn-nnnnnnnnnn

Reason:

The page range for the area being processed.

Action:

None.

AUDT005I CURRENT PAGE -nnnnnnnnnn (nnn%)

Reason:

The number of the current page and the percentage of pages thathave been processed.

Action:

None.

AUDT006I number-of-records RECORDS IN INPUT FILE

Reason:

The number of records contained in the input file.

Action:

None.

AUDT007I number-of-records RECORDS READ (nnn%)

Reason:

The number of the current record and the percentage of records thathave been read.

Action:

None.

AUDT008I INDEX SET nnn OF nnn, index-set-name

Reason:

The index set being processed and its sequence in the total numberof index sets.

Action:

None.

AUDT009I number-of-records IXDET RECORDS READ

Reason:

The number of IXDET records read.

Action:

None.

AUDT010E UNABLE TO FIND MESSAGE NUMBER message-id IN PROGRAMmodule-name MESSAGE TABLE

Reason:

A message number cannot be found in the designated module message table.

Action:

Contact Computer Associates Product Support.

AUDT011E INVALID COMMUNICATION SWITCH nnnn PASSED TO PROGRAMUSRAUDT

Reason:

USRAUDT received an invalid communication switch.

Action:

Contact Computer Associates Product Support.

AUDT012I DB/REORG IS BETWEEN STEPS PERFORMING A GENERAL SERVICEFUNCTION

Reason:

The utility is still executing, but it is not performing one of the primary steps.

Action:

None.

CALL901E PARAMETER LIST ERROR - PGM=module-name

Reason:

Module could not be called because of an internal problem.

Action:

Contact Computer Associates Product Support.

CALL902E NOT FOUND IN LIBRARY - PGM=module-name

Reason:

Module cannot be located in the available load or core-imagelibraries.

Action:

Locate the load or core-image library that contains module and make it available to the job.

CALL903E NOT ENOUGH STORAGE - PGM=module-name

Reason:

Module cannot be loaded due to insufficient GETVIS area (VSE/ESAonly).

Action:

Resubmit the job with a smaller SIZE= parameter or run in larger partition.

CALL904E ANCHOR TABLE LOAD FAILURE - PGM=GSSANKR

Reason:

An internal error has been detected.

Action:

Contact Computer Associates Product Support.

CALL905E UNANTICIPATED RETURN CODE=n PGM=module-name

Reason:

An internal error has been detected.

Action:

Contact Computer Associates Product Support.

DBST001E PROGRAM NAME ............... program-name

Reason:

A DBIO error has occurred. The program indicated was executing atthe time of the error.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST002E ERROR STATUS ............... error-code

Reason:

A DBIO error has occurred.

Action:

To find the meaning of the first two digits of the error code,refer to the CA IDMS major error codes listed in the CA IDMS Messages and Codes Guide or the supplemental list in the following figure. If the third and fourth digits of the error code fall within the ranges 00-99, see the list of CA IDMS minor error codes found in the CA IDMS Messages and Codes Guide.

DBST003E RECORD NAME ........ record-name

Reason:

A DBIO error has occurred. The record indicated was the last oneprocessed successfully before the error occurred.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST004E AREA NAME .......... area-name

Reason:

A DBIO error has occurred. The area indicated was the last oneprocessed successfully before the error occurred.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST005E ERROR SET .......... set-name

Reason:

A DBIO error has occurred. The set indicated was being processedwhen the error occurred.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST006E ERROR RECORD ....... record-name

Reason:

A DBIO error has occurred. The record indicated was beingprocessed when the error occurred.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST007E ERROR AREA ......... area-name

Reason:

A DBIO error has occurred. The area indicated was being processed when the error occurred.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST008E CURRENT DBKEY.......db-key

Reason:

A DBIO error has occurred. The value of the current db-key when the error occurred is indicated.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBST009E DIRECT DBKEY.......db-key

Reason:

A DBIO error has occurred. The value of the direct db-key when the error occurred is indicated.

Action:

The action required depends on interpretation of the DBIO error code given in Message: DBST002E.

DBIO Error Codes:

 DBIO MAJOR ERROR STATUS CODES

 GP = FIND/OBTAIN PAGE
 PR = PAGE RETURN

 DBIO MINOR ERROR STATUS CODES

 A1 = New page returned
 A2 = Function not supported
 A3 = Invalid page range
 A4 = Invalid qualifier
 A5 = Page not current of transaction
 A6 = Area not bound
 A7 = Page return not on
 A8 = Page return already on
 A9 = Fast scan not on
 B1 = Fast scan already on
 B2 = SR4 chain error
 B3 = SR2/SR3 chain error
 B4 = HDR/FTR page number mismatch
 B5 = Error closing file
 B6 = Record not logically deleted
 B7 = SMP currency error with page return on
 B8 = Bad 'line space used' length in footer
 B9 = No space in page
 C1 = Duplicate DBKEY
 C2 = Invalid Store
 C3 = Skipped index
 C4 = Broken chain
 C5 = IXDET member of multiple sets
 C6 = Ignored page reserve
 C7 = Invalid record length. Discrepancy in RDW lengths encountered
      during attempt to MODIFY RECORD. Run CLEANUP utility to remove
      LDELs from all areas to be processed by REORG.
 C8 = DMCL/SCHEMA CA IDMS release mismatch
 C9 = Decompress error
 D1 = Invalid record length
 D3 = FSTRIGGER not less than FSBUFFER, or FSTRIGGER equal to 0
 D4 = Invalid page displacement
 D5 = Invalid request
 D7 = GSDTPARM cannot be loaded
 D8 = Record not found in PSUB
 D9 = Segment names in the DBNAME table entry is mismatched with
 current DMCL
 DA = DBNAME not valid or segment name cannot be used as DBNAME

 Minor return codes prefixed with an I to indicate an internal error:

 I1 = Invalid parameter list
 I2 = Function not supported
 I3 = File already open/closed
 I4 = Insufficient work space--record read is larger
      than subschema description
 I5 = Invalid currency data
 I6 = VSAM block error
 I7 = Bad fast scan DMCL block
 I8 = file not assigned

DBST010E SUBSCHEMA CONTAINS AREAS WITH MIXED PAGE GROUPS OR MIXEDRADIX - NOT SUPPORTED

Reason:

An attempt was made to ready an area with a different page group to those areas already readied.

Action:

CA IDMS/DB Reorg cannot be run against a subschema that contains mixed page groups.

DEXT001E ERROR FOUND BY STEP INITIALIZATION ROUTINE--USERSUBS

Reason:

An unrecoverable error condition has been detected by USRDEXT.

Action:

Contact Computer Associates Product Support.

DEXT002I IIX SORTED DBKEYS/EXTRACTS READ number-of-records

Reason:

The number of records read from the IIXEXOL file.

Action:

None.

DEXT003I ALLOCATION EXTRACT RECORDS WRITTEN number-of-records

Reason:

The number of records written to the IIXEXTR file.

Action:

None.

DEXT004I IIX SORTED DBKEYS READ number-of-records

Reason:

The number of records read from the IIXSRKY file.

Action:

None.

DEXT005I IIX SORTED DBKEYS WRITTEN number-of-records

Reason:

The number of records written to the IIXSRKY file.

Action:

None.

DEXT006E COULD NOT CREATE FORMAT2 ALLOCATION EXTRACT RECORD BECAUSEEXTRACT INVALID

Reason:

The allocation extract file was created by CA IDMS/DB Reorg, but has been corrupted.

Action:

Verify that the allocation extract file (IIXEXOL) is valid and resubmit the job.

DRVR001E ERROR CALLING module-name, CALL PARAMETER ERROR

Reason:

The specified module cannot be called because of an internal error.

Action:

Contact Computer Associates, Inc. Product Support.

DRVR002E ERROR CALLING module-name, PROGRAM NOT FOUND

Reason:

The specified program cannot be located in the available library.

Action:

Locate the library that contains the module and make it availableto the job. Resubmit the job.

DRVR003E ERROR CALLING module-name, NOT ENOUGH STORAGE TO LOADPROGRAM

Reason:

The specified program cannot be loaded because of insufficient region size.

Action:

Increase the region size and resubmit the job.

DRVR004E UNANTICIPATED RETURN CODE r PGM = module name

Reason:

An internal error has been detected.

Action:

Contact Computer Associates Product Support.

GSFL001E ERROR OCCURRED DURING OPEN OF FILE file-name - GSSFILERETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to open the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the return codes indicated.

GSFL002E ERROR OCCURRED DURING READ OF FILE file-name - GSSFILERETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to read the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the return codes indicated.

GSFL003E ERROR OCCURRED DURING WRITE TO FILE file-name - GSSFILERETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to write to the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the return codes indicated.

GSFL004E ERROR OCCURRED DURING UPDATE OF FILE file-name - GSSFILERETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to update the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the return codes indicated.

GSFL005E ERROR OCCURRED DURING CLOSE OF FILE file-name - GSSFILERETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to close the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the return codes indicated.

GSFL999I file-id IS NOT VSAM - WILL TRY QSAM

Reason:

The indicated file is not a VSAM file. The message is preceded by asystem message indicating an open error for a VSAM file. If the attempt to open the file for QSAM processing is successful, CA IDMS/DB Reorg will continue with normal processing.

Note: The CA IDMS/DB Reorg file PAGUTIL needs direct access, either VSAM or BDAM.

Action:

None.

LMSG901E MESSAGE NOT IN TABLE........message-id ──module-name

Reason:

Message table module does not contain an entry with the named message-id.

Action:

Contact Computer Associates Product Support.

LMSG902E MESSAGE TABLE NOT FOUND........module-name

Reason:

Module cannot be located in the available load or core-imagelibraries.

Action:

Locate the load or core-image library that contains module and make it available to the job.

LMSG903E NOT ENOUGH STORAGE FOR TABLE........module-name

Reason:

Module cannot be loaded due to insufficient GETVIS area (VSE/ESAonly).

Action:

Resubmit the job with a smaller SIZE= parameter or run with a larger partition.

LMSG904E BAD MESSAGE PARM OR TABLE........module-name

Reason:

An internal processing error has been detected while processing thenamed message table.

Action:

Contact Computer Associates Product Support.

LMSG905E UNANTICIPATED RETURN CODE........nnnnn

Reason:

An internal processing error has been detected by the message tableprocessor.

Action:

Contact Computer Associates Product Support.

MTCH001E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected by USRMTCH.

Action:

Contact Computer Associates Product Support.

MTCH002I ALLOCATION EXTRACT RECORDS READ........number-of-record

Reason:

The number of allocation extract records read from the EXTRACT,PRIREAL, and SECREAL files.

Action:

None.

MTCH003I ALLOCATION EXTRACT RECORDS WRITTEN ....number-of-records

Reason:

The number of allocation extract records written.

Action:

None.

MTCH004I IIX DUPLICATE DBKEYS/EXTRACTS WRITTEN number-of-records

Reason:

The number of IIXEXOL records written.

Action:

None.

MTCH007E MISSING ALLOCATION EXTRACT RECORDS

Reason:

The allocation extract file was not created by CA IDMS/DB Reorg, or it isa legitimate file that has been corrupted.

Action:

Verify that the allocation extract file is valid. The allocation extract file consists of the EXTRACT, PRIREAL, and SECREAL files, sorted on first six bytes.

MTCH008E POINTER EXTRACT DOES NOT MATCH ANY ALLOCATION OR LDELRECORD

Reason:

Action:

MTCH009E COULD NOT CREATE FORMAT2 ALLOCATION EXTRACT RECORD BECAUSEFORMAT1 ALLOCATION INVALID

Reason:

The allocation extract file was created by CA IDMS/DB Reorg, but has been corrupted.

Action:

Verify that the allocation extract file (EXTRACT, PRIREAL, and SECREAL files) is valid and resubmit the job.

MTCH010E NO SET RECORD FOUND WHOSE ID MATCHES THE SET ID ON THEINPUT RECORD. SAVE SNAP AND CALL COMPUTER ASSOCIATES.

Reason:

An extract record on either of the EXTRACT, PRIREAL, or SECREAL input files contains a set-ID that does not match to any subschema set-ID's.

Action:

Contact Computer Associates Product Support.

NKWP001E UNRECOGNIZABLE MAJOR KEYWORD

Reason:

The major keyword underscored by asterisks (*******) in the AuditReport is misspelled or is in error and cannot be processed.

Action:

Correct the spelling of the keyword and resubmit the job.

NKWP002E DUPLICATE MINOR KEYWORD ENTERED

Reason:

The minor keyword underscored by asterisks (*******) in the AuditReport has already been entered on the parameter statement underscored.

Action:

Delete the duplicate minor keyword phrase and resubmit the job.

NKWP003E AN EQUAL SIGN (=) AND VALUE MUST FOLLOW THE KEYWORD

Reason:

The required equal sign and value after the keyword are missing.

Action:

Enter an equal sign followed by an appropriate value at thelocation underscored by an asterisk (*) in the Audit Report and resubmit the job.

NKWP005E MISSING RIGHT PARENTHESIS; PHRASE TERMINATED

Reason:

A set of open and closed parentheses is required.

Action:

Enter a right parenthesis to enclose the phrase or list, thenresubmit the job.

NKWP006E REPEATED LIST IMPROPERLY CONTINUED

Reason:

The last phrase on this statement is a list enclosed in parenthesesthat ends with a comma. However, the next statement entered does not continue the list.

Action:

Supply a continuation card and resubmit the job.

NKWP007E MISSING CONTINUATION CARD

Reason:

The previous statement ended with a comma, but this statementbegins with a major keyword.

Action:

Supply a continuation card and resubmit the job.

NKWP008E PRIORITY MUST CONTAIN NO MORE THAN 500 VALUES

Reason:

You supplied more than 500 record types and/or record names in thepriority list.

Action:

Correct and resubmit.

NKWP009E VALUE MUST BE xxxxxxxxxxxxxxxxxxxxx

Reason:

Value underscored by an asterisk (*) in the Audit Report isincorrect for the keyword.

Action:

Supply the appropriate value specified in the message and resubmit the job.

NKWP010E KEYWORD PHRASES NOT SEPARATED BY COMMA

Reason:

Each keyword phrase must be separated by a comma.

Action:

Supply a comma at the location underscored by an asterisk (*)in the Audit Report and resubmit the job.

NKWP011E UNRECOGNIZABLE MINOR KEYWORD

Reason:

The minor keyword underscored by asterisks (*******) in the AuditReport is misspelled or is in error and was not processed.

Action:

Correct the spelling of the minor keyword and resubmit the job.

NKWP012E MINOR KEYWORD OMITTED

Reason:

A minor keyword was omitted at the location underscored by anasterisk (*) in the Audit Report.

Action:

Enter the missing minor keyword and resubmit the job.

NKWP015E THESE KEYWORD(S) MUST BE SPECIFIED:xxxxxxxxxxxxxxxxxxxx

Reason:

The minor keyword(s) listed in the message was omitted. CA IDMS/DB Reorgcannot continue processing unless the keyword(s) shown is entered.

Action:

Supply the missing keyword(s) and resubmit the job.

NKWP018E MISSING VALUE NEED xxxxxxxxxxxxx

Reason:

A keyword was entered without a value. The variable portion of theerror message lists the acceptable values.

Action:

Enter the correct value at the location underscored by an asterisk (*) in the Audit Report and resubmit the job.

NKWP019E VALUE ENTERED PREVIOUSLY

Reason:

The value underscored by asterisks (****) on the Audit Report was already entered in the list. CA IDMS/DB Reorg cannot process this parameter unless you supply two different values.

Action:

Correct the value and resubmit the job.

NKWP020E VALUE MUST BE ASCENDING

Reason:

The value underscored by asterisks (******) on the Audit Report must be in ascending numerical sequence from the previous value in the list.

Action:

Rearrange the values in the list in ascending sequence and resubmit the job.

NKWP021E VALUE MUST BE DESCENDING

Reason:

The value underscored by asterisks (*******) on the Audit Report must be in descending numerical sequence from the previous value in the list.

Action:

Rearrange the values in the list in descending sequence and resubmit the job.

NKWP024E SECOND-LEVEL PRIORITY MUST CONTAIN AT LEAST ONE VALUE.

Reason:

A list or sublist cannot be empty. It must contain at least one valid record type or record name.

Action:

Insert one or more record types or record names in the PRIORITY statement at the location underscored by an asterisk (*) in the Audit Report.

NKWP027E SECOND-LEVEL-PRIORITY MUST CONTAIN NO MORE THAN 10 VALUES

Reason:

You supplied more than 10 record types and/or record names in a single, second-level-priority list. The eleventh entry is underscored by an asterisk (*) in the Audit Report.

Action:

Break the second-level-priority list into several second-level-priority lists and resubmit the job.

NKWP050E GSSNKWP INTERNAL ERROR -- NOTIFY COMPUTER ASSOCIATES PRODUCT SUPPORT

Reason:

An internal error has been detected.

Action:

Contact Computer Associates Product Support.

NKWP051E ERROR OCCURRED DURING CALL OF xxxxxxxx – GSS CALL RETURN CODE IS nn

Reason:

Module call processor error occurred.

Action:

Possible return codes are:

NKWP052E ERROR OCCURRED DURING LOAD OF xxxxxxxx – GSS LOAD RETURN CODE IS nn

Reason:

Module load processor error occurred.

Action:

Contact Computer Associates Product Support.

NKWP053E ERROR OCCURRED DURING WRITE OF xxxxxxxx – GSS PRINT RETURN CODE IS nn

Reason:

Error occurred during call of printer module.

Action:

Contact Computer Associates Product Support.

NKWP061E DD STATEMENT MISSING FOR DDNAME: xxxxxxxx

Reason:

A JCL DD card must be supplied.

Action:

Correct the JCL and resubmit the job.

NKWP062E LOGICAL UNIT NOT ASSIGNED: xxxxxxxx

Reason:

An ASSGN card must be supplied.

Action:

Correct the JCL and resubmit the job.

NKWP063E SYSIPT LRECL MUST BE 80.

Reason:

A parameter file with an LRECL other than 80 was supplied.

Action:

Create a parameter file with an LRECL of 80 and resubmit the job.

NKWP064E ERROR OCCURRED DURING OPEN OF xxxxxxxx FILE – GSS FILE RETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to open the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the indicated return codes.

NKWP065E ERROR OCCURRED DURING READ OF xxxxxxxx FILE – GSS FILE RETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to read the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the indicated return codes.

NKWP066E ERROR OCCURRED DURING CLOSE OF xxxxxxxx FILE – GSS FILE RETURN CODE IS n1,n2,n3,n4

Reason:

The file handler is unable to close the file.

Action:

See the tables in Return Codes for an explanation and appropriate action for the indicated return codes.

NKWP080W SKIPPING UNTIL NEXT RECOGNIZABLE STATEMENT

Reason:

Because of a previous error, the phrase(s) underscored by the capital letter X in the Audit Report has not been processed.

Action:

None.

NKWP081W SKIPPING UNTIL NEXT RECOGNIZABLE MINOR KEYWORD

Reason:

Because of a previous error, the value(s) underscored by the capital letter X in the Audit Report has not been processed.

Action:

None.

NKWP091I INPUT PARAMETER STATEMENT

Reason:

An CA IDMS/DB Reorg input parameter statement has been read. The entire80-byte image is displayed. Columns 1-72 will be processed.

Action:

None.

NKWP092I CONTINUATION STATEMENT

Reason:

The parameter statement continues a previous statement entered.

Action:

None.

NKWP093I COMMENT STATEMENT

Reason:

The parameter statement contains an asterisk (*) as the first non-blank character. The asterisk indicates that this is a comment statement, and it will not be processed.

Action:

None.

NKWP094I END OF PARAMETER INPUT

Reason:

All parameters that were entered have been read and processed by CA IDMS/DB Reorg.

Action:

None.

NKWP095I BLANK PARAMETER STATEMENT

Reason:

The parameter statement contains blanks in columns 1-72 and will not be processed.

Action:

None.

NKWP096E UNMATCHED APOSTROPHE. NEED xxxxxxxxxx

Reason:

A value was entered that contains an odd number of apostrophes.Literal values must begin and end with single apostrophes. To represent a single apostrophe within a literal, you must enter two apostrophes. The variable portion of the error message lists the acceptable values.

Action:

Correct the value underscored by asterisks (****) and resubmit the job.

NKWP097E BAD LITERAL FORMAT. NEED xxxxxxxxxxx

Reason:

A literal value was entered with improperly placed apostrophes.Literal values must begin and end with single apostrophes. To represent a single apostrophe within a literal, you must enter two apostrophes. The variable portion of the error message lists the acceptable values.

Action:

Correct the value underscored by asterisks (****) and resubmit the job.

NLYZ001E WRONG VERSION OF USRNLYZ MODULE, DB/REORG release-number-1 USRNLYZ release-number-2

Reason:

The release numbers of CA IDMS/DB Reorg's main program (USREORG) and USRNLYZ do not match. This error occurs if a new release of CA IDMS/DB Reorg is partially installed over a prior release, or if two releases of CA IDMS/DB Reorg are present and the available load or core-image libraries caused mixed releases of the program modules to be used.

Action:

Verify that CA IDMS/DB Reorg is correctly installed and that the proper load or core-image libraries are used. Resubmit the job.

NLYZ002E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

NLYZ003E NOSWEEP REQUESTED FOR AREA area-name. OWNER AND MEMBER(S)OF SET set-name ARE IN A NOSWEEP AREA

Reason:

You requested a NOSWEEP for an area containing a record owning a multi-member set that also has a member record in a NOSWEEP area.

Action:

Remove the NOSWEEP parameter statement for the area and resubmit the job.

NLYZ004E SUBSCHEMA DESCRIPTION OF record-name RECORD MISSING

Reason:

The subschema does not have a description of the record.

Action:

Correct the subschema and resubmit the job.

NLYZ005I END OF ANALYSIS REPORTS

Reason:

The Analysis Reports have been completed.

Action:

None.

NLYZ006I MAXIMUM RECORD SIZE FOR NEW SUBSCHEMA......nnnn

Reason:

Size information.

Action:

None.

NLYZ007I MAXIMUM CALC KEY SIZE FOR OLD SUBSCHEMA......nnnn

Reason:

Size information

Action:

None.

NLYZ008I MAXIMUM IX-DETAIL SIZE FOR OLD SUBSCHEMA......nnnn

Reason:

Size information

Action:

None.

NLYZ009I MAXIMUM IX-DETAIL SIZE FOR NEW SUBSCHEMA......nnnn

Reason:

Size information.

Action:

None.

NLYZ010I new/old SUBSCHEMA subschema-name WAS COMPILED compile-datecompile-time, DMCL dmcl-name, DBNAME dbname.

Reason:

Subschema compile information.

Action:

None.

NLYZ012I MAXIMUM SYMBOLIC KEY SIZE FOR INDEXED SET......nnnn

Reason:

Size information.

Action:

None.

NLYZ013I MAXIMUM RECORD SIZE FOR AN SR8 RECORD......nnnn

Reason:

Size information

Action:

None.

NLYZ014E IIX SET index-set-name CONTAINS HI-LO PAGE RANGE NOTCORRESPONDING TO RANGE OF ANY AREA

Reason:

The OR52 subschema control block, for the indicated index set, points to an AM57 subschema control block whose page ranges do not correspond to any AC56 page ranges in the subschema.

Action:

Contact Computer Associates Product Support. To verify the page ranges, you can browse the subschema load module to find the OR52 control block for the indicated set. The last fullword in the OR52 indicates the offset to the AM57. The HI-LO page ranges are in the fifth and sixth full words of the AM57. Compare these page ranges to the page ranges in the AC56 control blocks.

OPTX001I OBTAINS FOR AREA SWEEP ........ number-of-records

Reason:

The number of records obtained through area sweeps.

Action:

None.

OPTX002I OBTAINS FOR SET WALK ........number-of-records

Reason:

The number of records obtained through set walks.

Action:

None.

OPTX007I EXTRACT RECORDS WRITTEN ........ number-of-records

Reason:

The number of EXTRACT records written.

Action:

None.

OPTX008I PRIOPTA RECORDS WRITTEN ........ number-of-records

Reason:

The number of PRIOPTA records written.

Action:

None.

OPTX009I SECOPTA RECORDS WRITTEN ........ number-of-records

Reason:

The number of SECOPTA records written.

Action:

None.

OPTX010E WRONG VERSION OF USROPTX MODULE, DB/REORGrelease-number-1 USROPTX release-number-2

Reason:

The release numbers of CA IDMS/DB Reorg's main program (USREORG) and USROPTX do not match. This error occurs if a new release of CA IDMS/DB Reorg is partially installed over a prior release, or if two releases of CA IDMS/DB Reorg are present and the available load or core-image libraries cause mixed releases of the program modules to be used.

Action:

Verify that CA IDMS/DB Reorg is correctly installed and that the proper load or core-image libraries are used. Resubmit the job.

OPTX011E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

OPTX012E record-name REC SYM KEY CALCED TO page-number WHICH IS OUTSIDE REC PG RANGE OF page-number--page-number

Reason:

CALC record cannot be stored on suggested page because page number returned is outside record type's page range.

Action:

If GSSCALC was relinked to include IDMSCLCX, validate that link executed correctly. Validate also that IDMSCLCX routine is returning valid page numbers. If no problems exist, call Computer Associates Product Support.

OPTX013I NUMBER OF SORTED DBKEYS AT BOTTOM LEVEL number-of-records

Reason:

The number of bottom level records for IIX sorted db-keys with duplicate symbolic keys.

Action:

Use this figure in the calculation of the space needed for the IIXEXOL and IIXEXTR work files.

OPTX014I NUMBER OF IIXSRKY RECORDS THAT WILL BE CREATED number-of-records

Reason:

The number of records that will be created for the IIXSRKY work file.

Action:

Use the number of records to estimate the space needed for the IIXSRKY work file.

OPTX015I NUMBER OF IIX SORTED DBKEYS POINTING TO UPPER LEVELS number-of-records

Reason:

The number of IIX sorted db-key containing duplicates that point to upper levels.

Action:

Use the number in the calculation to estimate space needed for the IIXEXOL and IIXEXTR files.

OPTX016I STEP IIXSDBK WILL BE EXECUTED AND DD STATEMENTS 1) IIXEXOL2) IIXSRKY 3) IIXEXTR MUST BE DEFINED

Reason:

CA IDMS/DB Reorg found an area containing integrated index sets sorted by db-key. The IIXDBK step will be executed.

Action:

You must allocate space for the work files IIXEXOL, IIXSRKY, and SPFEXTR. See Overview.

OPTX017E SYSTEM OWNED IIX SET set-name DOES NOT CORRESPOND TO ANY SET DEFINITION

Reason:

While sweeping the old database CA IDMS/DB Reorg encountered an SR7 record whose name (or CALC key) does not match any set name in any OR52 in the subschema.

Action:

Check the database to be sure it is correct. Ensure that the old subschema contain a definition for set-name.

OPTX018E IIX SET index-set-name CONTAINS HI-LO PAGE RANGE NOT CORRESPONDING TO RANGE OF ANY AREA

Reason:

The OR52 subschema control block, for the indicated index set, points to an AM57 subschema control block whose page ranges do not correspond to any AC56 page ranges in the subschema.

Action:

Contact Computer Associates Product Support. To verify the page ranges, you can browse the subschema load module to find the OR52 control block for the indicated set. The last fullword in the OR52 indicates the offset to the AM57. The HI-LO page ranges are in the fifth and sixth fullwords of the AM57. Compare these page ranges to the page ranges in the AC56 control blocks.

OPTX019E record-name/set-name PAGE RANGE IS ONLY ONE PAGE page-number AND THAT IS SMP SO CANNOT STORE

Reason:

The indicated record or set has a page range of one page and that page is a space management page. The record or set cannot be stored.

Action:

Modify the schema to increase the page range.

OPTX020E record-name RETRIEVED WALKING SET set-name BUT record-name NOT DEFINED IN THIS SET

Reason:

The indicated record was retrieved while walking the indicated SR8 set, but the record is not defined as a member of the set.

Action:

Contact Computer Associates Product Support.

OPTX021E SR8 RECORD IN IIX SET set-name OVERFLOWED BUFFER DURING DECOMPRESSION OF SYMBOLIC KEYS

Reason:

Decompression of symbolic keys in an SR8 record required more buffer space than is available.

Action:

Check whether the SR8 records are correct. Contact Computer Associates Product Support.

OPTX022E SR8 RECORD IN IIX SET set-name TARGETED PAGE page-number IS NOT IN IIX SET PAGE RANGE

Reason:

The number of the target page for an SR8 record does not fall within the page range of the owner of the indicated integrated index set.

Action:

Contact Computer Associates Product Support.

OPTX023W THE DATABASE CONTAINS nnn OCCURRENCES OF RECORD ID id,WHICH IS NOT DEFINED IN THE OLD SUBSCHEMA

Reason:

While performing an area sweep, these records were encountered on the old database.

Action:

Proceed with the reorganization and these records will be eliminated from the new database, or begin the job again,providing an OLD SUBSCHEMA that defines these records.

If the record is a member of the CALC set, nnn will be twice as large as the actual number of record occurrences on the database.

PARM001I STATEMENT IGNORED WHEN RPT OR RESTART SPECIFIED ON THE PROCESS STATEMENT

Reason:

PROCESS statement keywords RPT or RESTART cause all following statements to be ignored.

Action:

None.

PARM002W RESTART KEYWORD IGNORED WHEN RPT KEYWORD IS SPECIFIED

Reason:

The RESTART parameter is being used with the RPT parameter in the same run.

Action:

Initiate another run of CA IDMS/DB Reorg using either the RPT parameter or the RESTART parameter.

PARM003E ERROR DETECTED IN module-name ERROR CODE RETURNED ISerror-code n

Reason:

An unrecoverable error condition has been detected. When the module name is GSDBLDP, possible error codes are:

100--Unable to build DMCL

104--Unable to load subschema

108--Unable to obtain storage for PSUB

2xx--GSSCALL error xx=CALLRC. See NKWP051E.

Action:

Correct the situation or contact Computer Associates Product Support.

PARM004E ONLY ONE PROCESS STATEMENT CAN BE SPECIFIED

Reason:

More than one PROCESS statement was found in file SYSIPT. Only one PROCESS statement is allowed.

Action:

Correct and resubmit the job.

PARM005E STATEMENT FLUSHED DUE TO INVALID OR MISSING PROCESS STATEMENT

Reason:

CA IDMS/DB Reorg did not find a valid PROCESS parameter statement in file SYSIPT.

Action:

A valid PROCESS statement is required and must be the first parameter statement in file SYSIPT. Correct and resubmit the job.

PARM006E NO VALID COPY STATEMENTS ENCOUNTERED - AT LEAST ONE COPY STATEMENT MUST BE SPECIFIED

Reason:

CA IDMS/DB Reorg did not find a valid COPY parameter statement in file SYSIPT.

Action:

At least one valid COPY parameter statement must be given in file SYSIPT. Correct and resubmit the job.

PARM008E MEMBER LOADED FOR new/old SUBSCHEMA IS NOT A SUBSCHEMA

Reason:

Member loaded is not a subschema. If subschema name is correct,then the subschema has been corrupted in the load or core-image library.

Action:

Verify subschema name. If subschema has been corrupted, then recreate it and resubmit the job.

PARM010E MEMBER LOADED FOR DMCL OF new/old SUBSCHEMA IS NOT A DMCL

Reason:

Member loaded for DMCL of subschema is invalid. If DMCL name iscorrect, the DMCL has been corrupted in the load or core-image library.

Action:

Verify subschema name. If DMCL has been corrupted, recreate it and resubmit the job.

PARM011E NOT ENOUGH STORAGE TO BUILD INTERNAL PROCESSING TABLE

Reason:

There is insufficient storage for CA IDMS/DB Reorg to execute.

Action:

Under VSE/ESA, use a larger partition or a smaller SIZE=parameter. Under z/OS or OS/390, use a larger REGION. Resubmit the job.

PARM012E SUBSCHEMA subschema-name-1 FROM PARAMETER INPUT DOES NOT MATCH SUBSCHEMA subschema-name-2 FROM LAST RUN

Reason:

The subschema name from the parameter input file and the control file of a previous run must be the same. When this error occurs, it is likely that the wrong parameter input or control file from a previous run is being used.

Action:

Verify that parameter input and control files are correct. Verify that the load module core image library name and the CSECT name of the subschema are equal. Resubmit the job.

PARM013E ALL DB/REORG STEPS HAVE SUCCESSFULLY EXECUTED

Reason:

An attempt was made to restart CA IDMS/DB Reorg after it finished executing.

Action:

None.

PARM014E NAME SPECIFIED FOR RPT/RESTART IS NOT A VALID STEP NAME

Reason:

The step name specified in not a valid CA IDMS/DB Reorg step.

Action:

Correct the step name and resubmit the job.

PARM015E ALL STEPS PRIOR TO RPT/RESTART STEP HAVE NOT SUCCESSFULLY EXECUTED

Reason:

CA IDMS/DB Reorg has not completed all steps prior to the one specified by the RESTART parameter.

Action:

Specify a step for RESTART that has completed processing in a prior run or the step that immediately follows the last step processed in a prior run.

PARM016E NOSWEEP AREA area-name MISSING FROM new/old SUBSCHEMA

Reason:

The specified NOSWEEP area only exists within one of thesubschemas.

Action:

NOSWEEP can only be specified for areas that exist in both the old and new subschemas. Correct and resubmit the job.

PARM017E NOSWEEP AREA area-name HAS NO SET LINKAGE WITH ANY COPY AREAS

Reason:

The specified NOSWEEP area does not have set linkage with any COPY areas.

Action:

A NOSWEEP parameter statement is not necessary for an area that does not have set linkage to at least one COPY area. Correct and resubmit the job.

PARM018E set-name SET NOT IN new/old SUBSCHEMA

Reason:

Action:

The specified set must exist with the same participating records in both old and new subschemas. Correct and resubmit the job.

PARM019E pointer-type DBKEY DISPLACEMENTS DO NOT MATCH BETWEEN SUBSCHEMAS FOR owner-or-member RECORD record-name IN SET set-name

Reason:

Specified db-key displacements for a given record type did not match between the old and new subschemas.

Action:

Db-key displacements for member and owner records must match between the old and new subschemas. Correct and resubmit the job.

PARM020E MEMBER member-name OF SET set-name NOT IN new/old SUBSCHEMA

Reason:

Member of the set designated does not exist in both the old and new subschemas.

Action:

Member of the set must exist in both the old and new subschemas. Correct and resubmit the job.

PARM021E new/old SUBSCHEMA record-name RECORD NOT IN old/new SUBSCHEMA

Reason:

The record exists in only one subschema.

Action:

Verify the subschemas. Correct and resubmit the job.

PARM022E AREA area-name NEEDS TO BE A COPY AREA FOR RECORD record-name IN new/old SUBSCHEMA

Reason:

The record indicated does not reside in the same area in both the old and new subschemas. Both areas must be copied to move the record to a different area.

Action:

Supply a copy statement for the additional area indicated in the message and resubmit the job.

PARM023E STOP AFTER STEP CANNOT PRECEDE RESTART STEP

Reason:

The step specified in the STOP AFTER parameter is processed before the step specified in the RESTART parameter.

Action:

Change the incorrect STOP AFTER or RESTART value. Resubmit the job.

PARM027E NO record-name RECORDS FOR INDEX SET index-set-name IN THE DATABASE

Reason:

Record-name records for index set are missing.

Action:

Correct this condition and resubmit the job.

PARM033E AREA NAME NOT IN new/old SUBSCHEMA

Reason:

An area was specified in a COPY or NOSWEEP statement that does not exist in both the old and the new subschemas.

Action:

Correct this condition and resubmit the job.

PARM034E AREA NAME PREVIOUSLY SPECIFIED IN A COPY STATEMENT

Reason:

The same area cannot be specified in two copy statements.

Action:

Correct the input parameters and resubmit the job.

PARM035E MULTIPLE OCCURRENCES OF SAME PARAMETER STATEMENT

Reason:

For NOSWEEP or COPY, this parameter statement has already been given for this area.

Action:

Remove the conflicting NOSWEEP or COPY parameter statement. Resubmit the job.

PARM039E RECORD record-name NOT IN AREA area-name IN NEW SUBSCHEMA

Reason:

The COPY statement PRIORITY parameter specifies a record that does not reside in the area named in the copy statement area parameter for the subschema named.

Action:

Correct the record name. Resubmit the job.

PARM041E AREA NAME PREVIOUSLY SPECIFIED IN A NOSWEEP STATEMENT

Reason:

A COPY statement and a NOSWEEP statement specify the same area.

Action:

Remove the conflicting NOSWEEP or COPY parameter statement.Resubmit the job.

PARM042E PAGE RESERVE VALUE GREATER THAN MAXIMUM FREE SPACE ON APAGE

Reason:

The COPY statement PAGE RESERVE parameter specifies a value that is too large.

Action:

Correct the PAGE RESERVE value. Resubmit the job.

PARM043I NO PARAMETER ERRORS DETECTED

Reason:

The parameter statement just processed did not contain any errors.

Action:

None.

PARM044I ERROR(S) DETECTED IN PARAMETER STATEMENT

Reason:

The parameter statement just processed contained one or more errors.

Action:

None.

PARM046E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

PARM047E PARAMETER INPUT FILE CONTAINS NO STATEMENTS

Reason:

File SYSIPT was empty.

Action:

Place parameter statements in file SYSIPT. Resubmit the job.

PARM050E INDEX SET index-set-name RESIDES IN COPY AREA IN new/old SUBSCHEMA BUT NOT IN old/new SUBSCHEMA

Reason:

The named IIX index set resides within a COPY area for only one of the subschemas.

Action:

Give a COPY parameter statement to resolve the error condition. Resubmit the job.

PARM051E LOCATION MODE CHANGE FOR record-name RECORD. AREA area-name AND AREA area-name MUST BE COPY AREAS

Reason:

The named record had its location mode changed. The named areas must be copy areas.

Action:

Give two COPY parameter statements to resolve the error condition. Resubmit the job.

PARM052E LOCATION MODE CHANGE FOR record-name RECORD. AREA area-name MUST BE A COPY AREA

Reason:

The named record had its location mode changed. The named area must be a copy area.

Action:

Give a COPY parameter statement to resolve the error condition. Resubmit the job.

PARM053E FORMAT AND/OR LENGTH OF record-name CHANGED

Reason:

The record indicated had its format and/or length changed from the old subschema to new subschema. Additionally, for a variable length record, the control length may have changed. This type of change is a restructure and is not supported.

Action:

Correct this condition and resubmit the job.

PARM057E MEMBER LOADED FOR new/old SUBSCHEMA CONTAINS INTEGRITY ERRORS

Reason:

The subschema specified in the PROCESS statement has a format or content error.

Action:

Correct the subschema or verify its name in the PROCESS statement and resubmit the job.

PARM058E MEMBER LOADED FOR new/old SUBSCHEMA CONTAINS ONE OR MORE NATIVE VSAM FILES

Reason:

The current release of CA IDMS/DB Reorg does not support the processing of native VSAM files.

Action:

Create a subschema (NEW or OLD) which does not include native VSAM files and resubmit the job using the changed subschema.

PARM059E PRIVACY LOCK ON FOR level-name level-identifier IN new/old SUBSCHEMA

Reason:

A requested reorganization cannot be executed because a privacy lock is active for the named area, set, or record.

Action:

Create a subschema without a privacy lock and make it available to CA IDMS/DB Reorg. Resubmit the job.

PARM062E RECORD record-name PARTICIPATES IN SETS NOT DEFINED BY THE NEW SUBSCHEMA

Reason:

The indicated record is a member or an owner of sets that are not defined in the new subschema.

Action:

Define a subschema that includes all sets in which the records participate. After making the necessary changes, resubmit the job.

PARM064E INFORMATION/REPLY ROUTE CODE PARAMETER DOES NOT APPLY WHEN USER SPECIFIES (NO) ON DSPLYINT PARAMETER

Reason:

Both DSPLYINT=NO and the INFOROUTE or REPLYROUTE parameter were specified.

Action:

Specify another option for DSPLYINT or delete the INFOROUTE and/or REPLYROUTE.

PARM065E INFORMATION/REPLY ROUTE CODE CLASS 11 IS INFORMATIONAL ONLY--USER MUST SPECIFY ROUTE CODE THAT ALLOWS REPLIES

Reason:

A class 11 route code was specified. Class 11 is not acceptable because it only allows display of information and does not allow the operator to reply.

Action:

Specify a route code that allows the operator to reply.

PARM066E RECORD record-name IN NEW SUBSCHEMA IS VARIABLE WITHOUT AN OCCURS DEPENDING ON CLAUSE

Reason:

The indicated record is defined with a MINIMUM FRAGMENT clause, but does not have an OCCURS DEPENDING ON clause.

Action:

Remove the FRAGMENT clause from the new subschema or add an OCCURS DEPENDING ON clause.

PARM067E INDEX SET index-set-name DEFINED IN old/new SUBSCHEMA BUTNOT IN new/old SUBSCHEMA

Reason:

The old and new subschemas do not correspond.

Action:

Define the index set in either the old or the new subschema as required.

PARM068E MEMBER record-name IS IN OLD SUBSCHEMA AND MEMBER record-name IS IN NEW SUBSCHEMA FOR INDEX SET index-set-name

Reason:

The member record is inconsistent between the old and new subschema.

Action:

Change the member record in either the old or the new subschema to match the other.

PARM069E NAME OF INDEX SET index-set-name IN OLD SUBSCHEMA DIFFERSFROM INDEX SET NAME index-set-name IN NEW SUBSCHEMA

Reason:

Index set names are inconsistent between the old and new subschema.

Action:

Change the index set name in either the old or the new subschema to match the other.

PARM070E area-name AREA CANNOT BE NOSWEEP SINCE OWNER OF SET set-name IN COPY AREA

Reason:

The indicated area was designated NOSWEEP and it contains records that are linked (as members) to an SR8 set in a copy area.

Action:

Remove the NOSWEEP statement for the indicated area. Resubmit the job.

PARM071E IIX SET index-set-name CONTAINS HI-LO PAGE RANGE NOT CORRESPONDING TO RANGE OF ANY AREA

Reason:

The OR52 subschema control block, for the indicated index set, points to an AM57 subschema control block whose page ranges do not correspond to any AC56 page ranges in the subschema.

Action:

Contact Computer Associates Product Support. To verify the page ranges, you can browse the subschema load module to find the OR52 control block for the indicated set. The last fullword in the OR52 indicates the offset to the AM57. The HI-LO page ranges are in the fifth and sixth fullwords of the AM57. Compare these page ranges to the page ranges in the AC56 control blocks.

PARM072E IIX SET index-set-name IS IN A COPY AREA IN THE new/old SUBSCHEMA BUT IS NOT IN A COPY AREA IN THE new/old SUBSCHEMA

Reason:

The integrated index set owner was found in a copy area in one subschema, but not in the other subschema.

Action:

Add another COPY statement that includes the area containing the integrated index in the other subschema.

PARM073E OPERATOR COMMUNICATIONS REQUESTED--NOT PERMITTED IN AVM/ESA ENVIRONMENT

Reason:

Unsupported function.

Action:

The DSPLYINT parameter is not functional in a VM/ESA environment.

PARM074E record-name, MEMBER OF UNDEFINED SET(S) IN old/new SUBSCHEMA

Reason:

The SET(S) this record participates in is not defined in the noted subschema.

Action:

Add the SETS(S) to the appropriate subschema.

PARMO75E INVALID USER WORK AREA SIZE PASSED

Reason:

Invalid user work area size passed in call to GSDBLDP.

Action:

Size must be from 64 to 256 inclusive

PARM076E SUBSCHEMA AREA NOT FOUND IN THE DMCL

Reason:

An area was specified in the subschema which was not found in the DMCL.

Action:

Use a DMCL that contains all areas in the subschema.

PARM077E SUBSCHEMA subschema-name DEFINES AN SQL DATABASE - NOTSUPPORTED

Reason:

CA IDMS/DB Reorg does not currently support SQL databases.

Action:

Do not run an CA IDMS/DB Reorg against an SQL database.

PARM078E BLOCKNUM nnn MUST BE IN RANGE 1:32

Reason:

The BLOCKNUM parameter which specifies the blocking factor for the CNTRL1, CNTRL2, and PAGUTIL work files must be in the range from 1 to 32.

Action:

Correct the BLOCKNUM value and re-run the job.

PARM079E BLOCKNUM nnn FROM PARAMETER INPUT DOES NOT MATCH BLOCK NUMyyy FROM LAST RUN.

Reason:

The BLOCKNUM parameter specified in a RESTART run must match that from the previous run.

Action:

Correct the BLOCKNUM value and re-run the job.

PARM080W FSBUFFERS KEYWORD WAS BYPASSED - REFER TO SYSIDMS PREFETCH CAPABILITY.

Reason:

The FSBUFFER parameter was included on the PROCESS statement. This is no longer valid. It has been replace by the SYSIDMS prefetch capability.

Action:

None- the parameter is ignored.

PRIA001E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

PRIA002I PRIOPTA RECORDS READ........ number-of-records

Reason:

The number of PRIOPTA records that have been read.

Action:

None.

PRIA003I PRIREAL RECORDS WRITTEN ........ number-of-records

Reason:

The number of PRIREAL records written.

Action:

None.

PRIA004I UNALLOC RECORDS WRITTEN ........ number-of-records

Reason:

The number of UNALLOC records written.

Action:

None.

PRIA005I PAGUTIL RECORDS WRITTEN ........ number-of-records

Reason:

The number of PAGUTIL records written.

Action:

None.

PRIA006I PAGUTIL RECORDS UPDATED ........number-of-records

Reason:

The number of PAGUTIL records updated.

Action:

None.

PRIA012E MISSING PRIOPTA RECORDS

Reason:

The PRIOPTA file was not created by CA IDMS/DB Reorg or it is a legitimate file that has been corrupted.

Action:

Verify that the PRIOPTA file is from the present run. Resubmit the job.

PRIA013E RECORD-ID record-id NOT IN new/old SUBSCHEMA

Reason:

The record-ID does not exist in the subschema designated.

Action:

Correct the subschema or verify its name in the PROCESS statement and resubmit the job.

PRIA014E RECORD-ID record-id IS CALC RECORD MISSING ITS CALC SET

Reason:

PRIOPTA contains the record defined as CALC but the program is unable to locate its CALC set.

Action:

Correct the subschema or verify its name in the PROCESS statement and resubmit the job.

PRIA015E RECORD-ID record-id IS A CALC RECORD WITH DUPLICATE SYMBOLIC KEYS BUT THE NEW SUBSCHEMA PROHIBITS DUPLICATES

Reason:

The location mode of the record is being changed from VIA to CALC with a DUPLICATES NOT ALLOWED option, but duplicate symbolic keys exist in the old database.

Action:

Eliminate duplicates for the record or redefine the record with DUPLICATES ALLOWED option in the new subschema and resubmit the job. CA IDMS/DB Reorg cannot delete records from the database.

PRIA016E SYSTEM OWNED IIX SET index-set-name DOES NOT CORRESPOND TO ANY SET DEFINITION

Reason:

An SR7 was obtained whose set name (or CALC key) does not match any set name in the OR52 subschema control blocks in the subschema.

Action:

Contact Computer Associates Product Support.

PRIA017E IIX SET index-set-name CONTAINS HI-LOW PAGE RANGE NOT CORRESPONDING TO RANGE OF ANY AREA

Reason:

The OR52 subschema control block, for the indicated index set, points to an AM57 subschema control block whose page ranges do not correspond to any AC56 page ranges in the subschema.

Action:

Contact Computer Associates Product Support. To verify the page ranges, you can browse the subschema load module to find the OR52 control block for the indicated set. The last fullword in the OR52 indicates the offset to the AM57. The HI-LO page ranges are in the fifth and sixth fullwords of the AM57. Compare these page ranges to the page ranges in the AC56 control blocks.

PRNT001E ERROR IN GENERAL SERVICE PRINT PROGRAM

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

PRST001I RESTART DATA........old/new SUBSCHEMA subschema-name

Reason:

CA IDMS/DB Reorg subschema and step status information for the RESTART parameter.

Action:

None.

PRNT910E A SEVERE ERROR OCCURRED DURING OUTPUT TO THE SYSLST FILE

Reason:

GSSCALL experienced a problem invoking GSSPRINT.

Action:

Ensure all necessary programs are available in your steplib or LIBDEF.

PRST002I RESTART WITH ........step-name

Reason:

The CA IDMS/DB Reorg step where you should continue processing after interrupting CA IDMS/DB Reorg.

Action:

None.

PRST003I DATASET DISPOSITION FOR RESTART ........file-namedisposition step-name

Reason:

CA IDMS/DB Reorg file status information for RESTART parameter.

Action:

None.

RCTL001E INVALID RECORD ID. IT SHOULD READ record-id-1 BUT INSTEAD IT READ record-id-2

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

RCTL002E INADEQUATE STORAGE AVAILABLE FOR REQUEST OF n

Reason:

There is insufficient storage for CA IDMS/DB Reorg to execute. The amountof storage requested was n bytes.

Action:

Under VSE/ESA, use a larger partition or smaller SIZE= parameter. Under z/OS or OS/390, use a larger REGION. Resubmit the job.

RCTL003E NBR OF BYTES OF PSUB LOADED BY USRRCTL EXCEEDS PSUB LENGTH VALUE CONTAINED IN CONTROL AREA

Reason:

The integrity of CNTRL1/CNTRL2 files has been compromised.

Action:

Contact Computer Associates Product Support.

RCTL004E NBR OF BYTES OF PSUB LOADED BY USRRCTL IS LESS THAN PSUB LENGTH VALUE CONTAINED IN CONTROL AREA

Reason:

The integrity of CNTRL1/CNTRL2 files has been compromised.

Action:

Contact Computer Associates Product Support.

RCTL005I SINCE ERROR DETECTED IN FILE file-name-1, USRRCTL WILL TRY TO READ FILE file-name-2

Reason:

Control file-1 could not be read successfully, so backup control file-2 will be tried.

Action:

None.

RCTL006I ERROR DETECTED IN FILE file-name AND THERE ARE NO MORE FILES TO READ

Reason:

Control file designated could not be read successfully.

Action:

None.

RCTL007I USRRCTL SUCCESSFULLY COMPLETED USING FILE file-name

Reason:

Control file designated was successfully processed by USRRCTL.

Action:

None.

RORG001E ERROR DETECTED IN module-name ERROR CODE RETURNED IS n

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

RORG002E ERROR LINKING TO module-name, LINK PARAMETER ERROR

Reason:

USREORG is unable to call this module due to internal error.

Action:

Contact Computer Associates Product Support.

RORG003E ERROR LINKING TO program-name, PROGRAM NOT FOUND

Reason:

Module cannot be located in the available load or core image libraries.

Action:

Locate the load or core image library that contains the module and make it available to the job. Resubmit the job.

RORG004E ERROR LINKING TO module-name, NOT ENOUGH STORAGE TO LOAD PROGRAM

Reason:

The module cannot be loaded due to insufficient GETVIS area (VSE/ESA only).

Action:

Resubmit the job with a smaller SIZE= parameter. A larger partition may also be required.

RORG005E ERROR IN SORT PROGRAM module-name INVALID SORT FIELD PARAMETER

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

RORG006E ERROR IN SORT PROGRAM module-name INVALID SORT RECORD PARAMETER

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

RORG007E ERROR IN SORT PROGRAM module-name E35 PROGRAM NOT FOUND

Reason:

The module cannot be located in the available load or core image libraries.

Action:

Locate the load or core image library that contains the module and make it available to the job. Resubmit the job.

RORG008E ERROR IN SORT PROGRAM module-name NOT ENOUGH STORAGE TO LOAD E35 PROGRAM

Reason:

Module cannot be loaded due to insufficient GETVIS area (VSE/ESA only).

Action:

Resubmit the job with a smaller SIZE= parameter. A larger partition may also be required.

RORG009E ERROR IN SORT PROGRAM module-name SORT UTILITY ERROR

Reason:

The call to the installation-provided sort program failed with anon-zero return code.

Action:

See your installation's sort program documentation for an explanation of the return code and any other sort program messages. Correct and resubmit the job.

RORG010E ERROR IN SORT PROGRAM module-name ERROR PROCESSING INPUT FILE

Reason:

GSSFILE failed while processing the input file. This error could also be caused by incorrect JCL.

Action:

Verify that the JCL is appropriate and resubmit the job. If no JCL or other user errors can be found, report the error to Computer Associates Product Support.

RORG011E ERROR IN SORT PROGRAM module-name REPORTED IN PREVIOUS MESSAGE

Reason:

Module detected an error. The error was reported in the preceding message.

Action:

Verify that the JCL is appropriate and resubmit the job. If no JCL or other user errors can be found, report the error to Computer Associates Product Support.

RORG012I STEP INTENTIONALLY BYPASSED

Reason:

The current step was bypassed because it was not needed.

Action:

None.

RORG013I DATABASE REORGANIZATION COMPLETE

Reason:

The database reorganization process is complete.

Action:

None.

RORG014E ERROR OCCURRED ON CALL TO RESET UTILITY USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

SECA001E ERROR FOUND BY STEP INITIALIZATION ROUTINE - USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

SECA002I SECOPTA RECORDS READ ........ number-of-records

Reason:

The sum of the SECOPTA and UNALLOC records read.

Action:

None.

SECA003I SECREAL RECORDS WRITTEN ........ number-of-records

Reason:

The number of SECREAL records written.

Action:

None.

SECA004I PAGUTIL RECORDS READ ........ number-of-records

Reason:

The number of PAGUTIL records read.

Action:

None.

SECA005I PAGUTIL RECORDS WRITTEN ........ number-of-records

Reason:

The number of PAGUTIL records written.

Action:

None.

SECA006I PAGUTIL RECORDS UPDATED ........ number-of-records

Reason:

The number of PAGUTIL records updated.

Action:

None.

SECA012E MISSING SECONDARY ALLOCATION RECORDS

Reason:

Secondary allocation file was not created by CA IDMS/DB Reorg, or it is alegitimate file that has been corrupted.

Action:

Verify that the secondary allocation file is valid. The secondary allocation file consists of the SECOPTA and UNALLOC files. Resubmit the job.

SECA013E RECORD-ID record-id NOT IN new/old SUBSCHEMA

Reason:

The record-ID is not defined in the subschema designated. Probable cause is a CNTRL1/CNTRL2 file that has been corrupted.

Action:

Correct this condition and resubmit the job.

SECA014E NO SPACE LEFT IN AREA area-name FOR MINIMUM ROOT OF RECORD record-name

Reason:

The area is full.

Action:

Correct this condition by creating adequate space in the new subschema for the area indicated, by decreasing the page reserve parameter value, by redistributing records to other areas, or by using a combination of these techniques. Resubmit the job.

SECA015E NO SPACE LEFT IN AREA area-name FOR RECORD record-name, WHICH CANNOT BE FRAGMENTED.

Reason:

The area is full. The number of bytes targeted to the area is greater than the allocated space.

Action:

Correct this condition by creating adequate space in the new subschema for the area indicated by allocating more space to the area, by redistributing records to other areas, or by using a combination of these methods. The situation arises when attempting to allocate space for the named record above. This record cannot be fragmented.

SECA016E AREA area-name IS FULL

Reason:

This area is full.

Action:

Correct this condition by creating adequate space in the new subschema for the area indicated, by decreasing the page reserve parameter value, by redistributing records to other areas, or by using a combination of these techniques. Resubmit the job.

SECA017E NO SET RECORD FOUND WHOSE ID MATCHES THE SET ID set-id ONINPUT RECORD. SAVE SNAP AND CALL SUPPORT

Reason:

No set record was found with the an ID that matches the ID found in the system-owned integrated index set.

Action:

Save the SNAP/dump and contact Computer Associates Product Support.

SECA018E NO AREA FOUND THAT CONTAINS IIX SET NUMBER set-id. SAVE SNAP AND CALL SUPPORT

Reason:

CA IDMS/DB Reorg could not find an area containing the indicated index set.

Action:

Save the SNAP/dump and contact Computer Associates Product Support.

SECA019E PROGRAM ATTEMPTING TO CREATE UPPER LEVEL IIX STRUCTURE WHEN NO BOTTOM LEVEL EXISTS

Reason:

The program encountered a serious logic flaw and could not continue.

Action:

Save the SNAP/dump and contact Computer Associates Product Support.

SETL001E ERROR OCCURRED ON CALL TO RESET UTILITY USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

SETL002I ALLOCX READ .............. number-of-records

Reason:

The number of ALLOCX records read.

Action:

None.

SETL003I DBREC WRITTEN .............. number-of-records

Reason:

The number of DBREC records written.

Action:

None.

SETL005I DATABASE RECORDS MODIFIED .............. number-of-records

Reason:

The number of database records modified.

Action:

None.

SETL006I RECORD PREFIXES HAVE BEEN ALTERED IN NON-COPY AREA area-name

Reason:

Records have been modified in the area indicated. The area was not specified in a copy statement.

Action:

None.

SNAP001E ERROR FOUND DURING SNAP DUMP - GSSSNAP RETURN CODE IS nnnnnnnnnn

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

STAT001I CA IDMS STATISTICS FOLLOW - - - - - - - - - - - - - - -- -

Reason:

CA IDMS statistics are reported following this message.

Action:

None.

STAT002I step-name STATISTICS FOLLOW - - - - - - - - - - - - - - --

Reason:

Statistics for the step are reported following the message.

Action:

None.

STOR001E ERROR OCCURRED ON CALL TO RESET UTILITY USRSUBS

Reason:

An unrecoverable error condition has been detected.

Action:

Contact Computer Associates Product Support.

STOR002I DBREC READ .............. number-of-records

Reason:

The number of DBREC records read.

Action:

None.

STOR003I DBREC STORED .............. number-of-records

Reason:

The number of database records stored.

Action:

None.

SYNC001E MODULE VERSIONS DO NOT MATCH. DB/REORG release-number-1module-name release-number-2

Reason:

The release numbers of CA IDMS/DB Reorg's main program (USREORG) and module-name do not match. This error occurs if a new release of CA IDMS/DB Reorg is partially installed over a prior release, or if two releases of CA IDMS/DB Reorg are present and the available load or core-image libraries cause mixed releases of the program modules to be used.

Action:

Verify that CA IDMS/DB Reorg is correctly installed and that the proper load or core-image libraries are used. Resubmit the job.

SYNC002E FILE SYNC CONTROL RECORD MISSING FROM file-name FILE

Reason:

The file designated was not created by CA IDMS/DB Reorg or it is a legitimate file that has been corrupted.

Action:

Verify that the file is valid. Resubmit the job.

SYNC003E file-name FILE NOT FOR CURRENT RUN OF CA IDMS/DB Reorg

Reason:

The file designated was created by CA IDMS/DB Reorg but is not to be used with this run of CA IDMS/DB Reorg.

Action:

Verify that the file is valid. Resubmit the job.

SYNC004E EXTRANEOUS FILE SYNC CONTROL RECORD READ FROM file-name FILE

Reason:

The file indicated was created by CA IDMS/DB Reorg but appears to be corrupted with extraneous records.

Action:

Verify that the file is valid. Resubmit the job.

SYNC005E file-name FILE SHOULD CONTAIN n1 RECORDS. CURRENT FILE COUNT IS n2 RECORDS

Reason:

The file is corrupt because of missing or extraneous records.

Action:

Verify that the file is valid and resubmit the job.

UTIL001E INVALID PARAMETER LIST PASSED TO MODULE module-name

Reason:

Module indicated has received an invalid parameter list.

Action:

Contact Computer Associates Product Support.

UTIL002E UNANTICIPATED ERROR OCCURRED IN PROGRAM module-name RETURN CODE WAS nnnn

Reason:

Module ended with the indicated return code.

Action:

Contact Computer Associates Product Support.

UTIL901E program-name PROGRAM WAS UNABLE TO PRINT MESSAGE message-number

Reason:

See the message following this one on the Audit Report.

Action:

See the message following this one on the Audit Report.

WCTL001E INVALID PSUB BLOCK ENCOUNTERED IN PROGRAM program-name

Reason:

An unusual processing situation has occurred and the utility cannot continue.

Action:

Contact Computer Associates Product Support.

WTOR000I ====> REPLY WITH REQUEST TO DB/REORG ****

Reason:

The Console Communication Facility has been activated. CA IDMS/DB Reorgis ready to accept console requests.

Action:

Enter a console communication command if desired.

WTOR001E ERROR - BAD SYNTAX, NO COMMAND GIVEN WITH REPLY

Reason:

A reply to WTOR000I was given but it did not contain a command.

Action:

Enter a console communication command.

WTOR002E ERROR - BAD SYNTAX, INTERVAL REQUEST GREATER THAN MAXIMUM(120)

Reason:

The value in the SET INTERVAL request is too large.

Action:

Enter a SET INTERVAL request in the range 0-120.

WTOR003E ERROR - BAD SYNTAX, INTERVAL REQUEST LESS THAN MINIMUM (0)

Reason:

The value in the SET INTERVAL request is too small.

Action:

Enter a SET INTERVAL request in the range 0-120.

WTOR004E ERROR - BAD SYNTAX, INVALID COMMAND/OPERAND IN REPLY

Reason:

A reply to WTOR000I was given but it did not contain a valid command/operand.

Action:

Enter a console communication command with a valid command/operand.

WTOR005I INTERVAL AND STEP DISPLAYS CANCELED, DISPLAY IS ON REQUEST ONLY

Reason:

A SET INTERVAL REQUEST command was successfully processed.

Action:

None.

WTOR006E ERROR - UNABLE TO ATTACH A DISPLAY INTERVAL RC = hex-word

Reason:

The display interval could not be established by USRINTV. An ABEND or internal error may be the cause. In VSE/ESA, lack of timer support in the partition used by CA IDMS/DB Reorg could also cause the error.

Action:

If no user error can be found, contact Computer Associates Product Support.

WTOR007I INTERVAL REQUEST ACCEPTED, CURRENT DISPLAY INTERVAL IS NOW nnn MINUTES

Reason:

A SET INTERVAL command was successfully processed.

Action:

None.

WTOR008I STEP REQUEST ACCEPTED, END OF STEP DISPLAY IS NOW ACTIVE

Reason:

A SET INTERVAL STEP command was successfully processed.

Action:

None.

WTOR009E DISPLAY TIMER IS NOT ACTIVE

Reason:

A SET INTERVAL STEP command was issued and the interval timer was turned off by a previous SET INTERVAL console command or it was established through the DISPLAY parameter or a SET INTERVAL command.

Action:

Establish a timer display interval with the SET INTERVAL console command. (VSE/ESA installations only: If this message appears in the Audit Report at the end of the job, the interval timer ended before the interval established in the SET INTERVAL command. Contact Computer Associates Product Support.)

WTOR010E subtask-name HAS ABENDED, SUBTASK ECB=hex-word

Reason:

The subtask designated has ended unexpectedly and the timer display cannot be reestablished once it has abended.

Action:

Contact Computer Associates Product Support.

WTOR011I DISPLAY INTERVAL HAS BEEN CANCELLED, DISPLAY IS ONLY ATEND OF STEP

Reason:

This message is displayed in response to a SET INTERVAL operator command.

Action:

None.