ARDP is the CA Archive Duplication Batch Utility Task Identification
Reason:
This message is part of the Archive Duplication batch job initialization. It indicates that the Archive Duplication batch job is attempting to utilize ICSF encryption, but the ICSF task is inactive.
Action:
Start ICSF task or set Sysgen Archive Encryption to N.
Reason:
Program CADSARUT received a non‑zero return code from the DUPLICATE process program CADSARDP.
Action:
Check the other error messages and correct the problem, then rerun the job.
Reason:
An invalid parameter was encountered processing OUTVOL= cards.
Action:
The DUPLICATE process does not support OUTVOL=POOL. Correct the parameter and rerun the job.
Reason:
This is an error message from program CADSARUT to notify you that the Archive Batch Utility did not complete successfully.
Action:
Check the other error messages and correct the problem, then rerun the job.
Reason:
An attempt is being made to add a record to the database and the database area is full.
Action:
Contact Technical Support for instructions about how to free the area.
Reason:
An attempt is being made to access the database through the currently running CA Dispatch using program DSEXARC but CA Dispatch is not active.
Action:
Do one of the following:
Reason:
An attempt is being made to access the database but the database is being used by another job; the other job is not allowing access.
Action:
Contact Technical Support for instructions about how to find the other job or task that is running.
Reason:
An attempt to perform a database function has failed.
Action:
Review Error Status output, correct the problem and resubmit the job.
Reason:
Program CADSARUT did not receive any VOLSER selection interface records from program CADSARCN.
Action:
Review program CADSARCN VOLSER selection criteria, correct the problem and resubmit the job.
Reason:
An error occurred in program CADSARUT while attempting to allocate or de‑allocate a tape data set.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while reading or writing a tape data set.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while attempting to perform a tape management function.
Action:
Review SYSGEN Tape Management selection, correct the problem and resubmit the job.
Reason:
An error occurred in program CADSARUT while attempting to perform a LDS REPORT query function.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while attempting to perform a LDS OPEN REPORT function.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while attempting to perform a LDS READ function.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while attempting to perform a LDS CLOSE function.
Action:
Save all error information and contact Technical Support.
Reason:
An error occurred in program CADSARUT while attempting to perform a LDS SET function.
Action:
Save all error information and contact Technical Support.
Reason:
Executing CADSARUT, OUTVOL=POOL was specified and no archive pool VOLSERs were defined to the CA Dispatch database.
Action:
Add archive pool VOLSERs to the database or specify OUTVOL=SCRATCH.
Reason:
After obtaining a VOLSER from the archive tape pool, the erasure of the record from the database failed.
Action:
Save all error information and contact Technical Support.
Reason:
An attempt to obtain storage for the Batch Utility failed.
Action:
Increase the region size for the CADSUTIL step.
Reason:
An attempt to obtain storage for named common area failed.
Action:
Increase the region size for the CADSUTIL step.
Reason:
An attempt to LOAD the named module for the Batch Utility failed.
Action:
Make sure that the CADSLOAD being used contains the following members; CADSUPAR, CADSUDB, CADSOVUT, CADSUOV and CADSULDS.
Reason:
You supplied an invalid or missing SYSIN command parm.
Action:
Check your SYSIN Command Parms to see if you input the correct parameters. Also, check to see whether you included the proper delimiters.
Reason:
The Batch Utility received an invalid return code from the named module.
Action:
Check the other error messages and correct problem and resubmit job.
Reason:
The named Batch Utility module encountered a Database Error.
Action:
Review Error Status output, correct problem and resubmit job.
Reason:
You supplied an invalid or missing SYSIN command parameter.
Action:
Check your SYSIN command parameters to see if you input the correct parameters. Also, check to see whether you included the proper delimiters.
Reason:
The named optional parameter is missing, default parameter assumed.
Action:
None.
Reason:
An attempt to perform a batch utility database function has failed due to an invalid function code.
Action:
Save all error information and contact Technical Support.
Reason:
An attempt to perform a database function has failed because the database is not available.
Action:
Review error status output, correct problem and resubmit job.
Reason:
An attempt to perform an LDS Access function has failed. You may also receive this message if:
Action:
Save all error information and contact Technical Support.
Reason:
The indicated ACIF processing program encountered an error attempting to update an ACIF Status File.
Action:
This message is preceded by messages DC970120 through DC970130. Perform the action required by the preceding messages. Rerun the ACIF request. If the error reoccurs, it is preceded by another error message. Save all error information and contact Technical Support.
Reason:
Parameter information is missing. Check the SYSOUT for the message CADSARCN ‑EXEC PARM =xxxxxx, where xxxxxx is the parameter. The message is blank after the =. LOGIC, LINES, and REPORTS parameters are missing.
Action:
Correct the problem, then resubmit the job.
Reason:
Invalid or missing LINES parameter; LINES must be numeric and greater than zero.
Action:
Correct the problem, then resubmit the job.
Reason:
Invalid or missing REPORTS parameter; REPORTS must be numeric and greater than zero.
Action:
Correct the problem, then resubmit the job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility did not encounter any valid execution parameters.
Action:
Supply valid input parameters, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered a missing or invalid FROMDATE= parameter.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered a missing or invalid TODATE= parameter.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered a FROMDATE that is greater than the TODATE.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an UPDATE switch not equal to Y or N.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE or CADSARUL notifies you that either the Batch Extract Request Utility or the Archive Database Merge Utility encountered a missing or invalid date in either the FROMDATE or TODATE parameters.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an invalid year date value in either the FROMDATE or TODATE parameters. Year must be greater than 0.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an invalid month date value in either the FROMDATE or TODATE parameters. Month must be less than or equal to 12.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an invalid day date value in either the FROMDATE or TODATE parameters. Day must be less than or equal to 31.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered a missing or invalid time in either the FROMDATE or TODATE parameters.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an invalid hour time value in either the FROMDATE or TODATE parameters. Hours must be less than or equal to 24.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered an invalid minutes time value in either the FROMDATE or TODATE parameters. Minutes must be less than or equal to 59.
Action:
Correct the input parameter, then resubmit job.
Reason:
This error message from program CADSBLDE notifies you that the Batch Extract Request Utility encountered a missing RECIPIENT value when specifying TYPE=R extract request.
Action:
Correct the input parameter, then resubmit job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered no valid execution parameters.
Action:
Supply valid input parameters and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered a missing or invalid FROMDATE= parameter.
Action:
Correct the input parameter and resubmit the job.
Reason:
This message is to inform you that the VIEW ARCH process has finished archiving MGGCLASS reports, and the report delete portion of the process is starting.
Action:
None. This message is informational only.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered a missing or invalid TODATE= parameter.
Action:
Correct the input parameter and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered a FROMDATE that is greater than the TODATE.
Action:
Correct the input parameter and resubmit the job.
Reason:
An attempt to obtain storage to perform the VIEW or VIEW ARCH process in programs CADSPSVW or CADSVIEW failed.
Action:
Increase the REGION size for the VIEW1 execute step in the CADSVIEW proc or PSVW1 execute step in the CADSPSVW proc.
Reason:
An internal logic error has occurred. The database record does not point to the correct report on the LDS data set.
Action:
Save all error information and contact Technical Support.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered an invalid month date value in either the FROMDATE or TODATE parameters. Month must be less than or equal to 12.
Action:
Correct the input parameter and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered an invalid day date value in either the FROMDATE or TODATE parameters. Day must be less than or equal to 31.
Action:
Correct the input parameter and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Utility encountered a missing or invalid time in either the FROMDATE or TODATE parameters.
Action:
Correct the input parameter and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered an invalid hour time value in either the FROMDATE or TODATE parameters. Hours must be less than or equal to 24.
Action:
Correct the input parameter and resubmit the job.
Reason:
This is an error message from program CADSARUL. The Archive Database Merge Utility encountered an invalid minutes time value in either the FROMDATE or TODATE parameters. Minutes must be less than or equal to 59.
Action:
Correct the input parameter and resubmit the job.
Where XXXX can be OPEN, READ, GETRP or LDEL
Reason:
An attempt to execute the LDS function failed during CADSVIEW processing.
Action:
For XXXXX=OPEN, GETRP, or LDEL: CADSVIEW skips the affected report and continues by processing next reports.
For XXXXX=READ: CADSVIEW stops processing.
Note: In both cases, contact Technical Support.
|