Previous Topic: 799RNext Topic: 79BE


79AE

LINERD error getting response, RC=<rc>

Reason

You entered a field name that requires a value without an associated value. This field has the PROMPT bit turned on in its FDE (PROMPT=YES in an @CFDE macro). You invoked the LINERD macro to get a response for the value of this field. The LINERD macro failed with <rc> as the return code.

Action

Determine the meaning of the LINERD return code by referring to the appropriate IBM CMS manual. Take any action indicated. If the return code indicates incorrect use of the LINERD macro, contact CA Support.