//stepname EXEC PGM=TMSCLEAN, // PARM='[TEST,]RESETCAT' //STEPLIB DD DSN=CAI.CTAPLINK,DISP=SHR //TMSRPT DD SYSOUT=A //EARLOUT DD DSN=resetcat.earlout, // DISP=(NEW,PASS,DELETE), // UNIT=SYSDA, // SPACE=(CYL,5), // DCB=(RECFM=FB,LRECL=376,BLKSIZE=15416) *NOTE [//TMSRPT89 DD SYSOUT=A] [//SYSIN DD *] [VOL=ssssss-eeeeee] [EXCLUDE=ssssss-eeeeee] [SCRPOOL=xxxxx] [FILE1DSN=pattern]
Note: The BLKSIZE may be any multiple of 376.
Parameter Definitions
Process normally, but do not update any TMC records. The records processed are written to EARLOUT to subsequently produce the Reset Catalog Control report, but the TMC is not updated. This parameter is optional, and if used, must be specified before RESETCAT.
Changes expiration date to CATALOG and turns off the Expired by Catalog Control indicator for TMC Volume and DSNB records if the Expired by Catalog Control indicator is on.
JCL Considerations
If the SYSIN DD is found, the TMC is processed based on the volumes specified in the range control statements. If no control statements are coded, the complete TMC is processed. A maximum of 20,000 range control statements is allowed. If the SYSIN DD is not found, then TMSCLEAN processes the complete TMC.
If the SYSIN DD is used, this DD must be coded. The range control statements are printed to this DD and any errors that found in the control statements are printed to this DD.
Range Control Statements
The VOL statement is used to select the volumes to be processed based on a starting and ending volume number. A single volume may be specified by only coding a start volume.
The SCRPOOL statement is used to select the volumes to be processed based on a scratch subpool name.
The FILE1DSN statement is used to select volumes based on the DSN of the first file on the volume, using standard CA 1 pattern masking. When the FILE1DSN statement is the only selection statement used, the specified pattern are processed. If FILE1DSN= statements is used with VOL and/or SCRPOOL statements, then only volumes within the requested ranges that match the pattern are processed.
The EXCLUDE statement selects the volumes you want to exclude from processing based on a starting and ending volume number. To specify a single volume, code only a start volume.
Start and end volumes must be six digit numbers. If the volume number has five or fewer digits, it must be padded with 0s.
EXCLUDE=001500-001575
The EXCLUDE control statement can be used without a VOL control statement.
Example: The control statement excludes the volser range of 001500-001550 from being processed by TMSCLEAN.
EXCLUDE=001500-001550
Note: If the volumes included match the volumes excluded, the exclude control statement overrides the include control statement.
|
Copyright © 2013 CA Technologies.
All rights reserved.
|
|