To spin a selected log to a sysout class, use the SPINLOG command.
Type: OPER command
Authority: To issue the SPINLOG command, you require OPER authority.
This command has the following format:
SPINLOG [AUDITLOG|ESPLOG|ENCORELG|CPEENQLG]
Spin the audit log.
Spin the log of RQEN (ENCREQ) IARs.
Spin the log of RQEN (CPEENQ) IARs.
Audit Log
A SPINLOG command with no operands acts upon z/OS Agent audit log. The AUDITLOG initialization parameter identifies the sysout class, and optionally the form number for spinning the audit log. An automatic spinlog exists for the audit log that is set with the AUDITLOG initialization parameter.
Related Information
For information on setting the print characteristics of z/OS Agent audit log, see the AUDITLOG initialization parameter.
Example: Display the SPINLOG
This example shows how to display the SPINLOG. In the example, 262 records from the audit log are spun to sysout class E.
OPER SPINLOG ESP1023I Auditlog dataset spun with 262 records to sysout class E
|
Copyright © 2013 CA.
All rights reserved.
|
|