Previous Topic: CAL2M043ENext Topic: CAL2M045W


CAL2M044W

Unable to create QRYPORT name token pair for monitor(xxxx) rc(nn)

Reason:

Jobflow Monitor was unable to create the name token pair for the monitor listed in the message. The CA 7 Web Client uses this name token pair to determine on which TCP/IP port to communicate with Jobflow Monitor. Jobflow Monitor continues to run, and the specified monitor instance continues to run, but the CA 7 Web Client cannot always communicate with Jobflow Monitor.

This message typically occurs when the name/token pair exists for the monitor listed in the message. Usually, a different JFM task other than the one containing the CAL2M044W error is monitoring the CA 7 instance.

Action:

Correct the problem. After the problem is corrected, restart the Jobflow Monitor task. For assistance, contact CA Support at ca.com/support.