Reason:
The Dynamic BTI Management facility was unable to locate the BATCHIN data sets for any of the batch terminals in the pool of available terminal numbers. The model DSN used to attempt to allocate the BATCHIN data sets is listed in the message.
Action:
Confirm that the model DSN listed in the message has the correct format for your BATCHIN/BATCHOUT data sets. If so, confirm that these data sets are cataloged and accessible on the system where the BTI job is being executed. Also, if the POOL= parameter is specified on the SASSBSTR execution PARM, check to ensure that the terminal numbers specified for the terminal pool are actually defined to CA WA CA 7 Edition and have BATCHIN/BATCHOUT data sets allocated for them.
If the model DSN listed in the message is NOT the correct format, specify the correct data set name prefix in the DSNPFX= keyword in the PARM data on the SASSBSTR execution statement.
|
Copyright © 2015 CA Technologies.
All rights reserved.
|
|