Previous Topic: Installation Verification ProcessNext Topic: Abend Codes


'Demand' Installation Verification Job

This step is not required but can be helpful in debugging if tracking problems occur (see the next step).

While both CA WA CA 7 Edition and ICOM are running on the same CPU, run the installation verification job to verify that CA WA CA 7 Edition is installed correctly. The job is CA07SVCT, U7TESTSV program. CA WA CA 7 Edition must submit this job.

Log on to CA WA CA 7 Edition through the application ID defined in the preparing for installation instructions (default = CA7). When the CA WA CA 7 Edition logon panel appears, enter MASTER for the USERID and no password. MASTER logs you on to CA WA CA 7 Edition using the installation-supplied default security.

To submit the installation verification job, issue the following command:

DEMAND,JOB=CA07SVCT    (job name prefix may have been changed)