Reason:
The job jjjjjjjj with CA 7 WA job number nnnn was not submitted to the indicated internal cross-platform node nodename or agentname. A parameter data error, driver proc error, or invalid keyword specified in the PARMLIB occurred. This message is followed by SSM0-90 which further explains the error.
Action:
Validate the internal cross-platform parameters by issuing a CA JCLCheck Workload Automation command (LJCK) against the job. This should show errors as to why the job is not getting submitted. If the second byte of message SSM0-90 EC= is one of the following, take appropriate actions:
Indicates a Driver Proc error. Verify valid DPROC usage
Indicates no storage for PARM data. Contact local CA Workload Automation SE support to ensure CA Workload Automation SE is not having storage problems.
Indicates internal data error when trying to retrieve the parameters from storage.
Indicates PARMnn where nn is not numeric.
Indicates a keyword exceeded eight characters in length. Check for valid keywords.
Indicates PARMnn error where nn is not specified or exceeds two bytes in length.
Indicates PARMnn length exceeds 256 bytes in length.
Indicates PARMnn where nn exceeds 64.
Indicates a keyword error, an unrecognizable keyword.
Indicates that a C-LANG statement exceeded 4 KB in size.
Indicates an internal error. An invalid function was passed to the program that builds the AFM.
|
Copyright © 2015 CA Technologies.