Previous Topic: CA-7.744Next Topic: CA-7.777


CA-7.750

SASSLOGM - LOGGING ERROR x

Reason:

The following shows the values of x:

1

An error condition was encountered in the SLOG macro.

2

An invalid request has been issued for the SLOG macro.

3

An active buffer could not be found for the Log data set. Most likely the buffer status area of memory has been overlaid.

4

An I/O error was encountered on the Log data set.

Issued by SASSLOGM.

Action:

When x equals:

1

Contact your installation specialist for assistance.

2

Contact your installation specialist for assistance.

3

Cancel CA Workload Automation SE with a dump and then use the emergency restart (TYPE=ERST) procedure to reinitialize CA Workload Automation SE. Contact your installation specialist when the dump is available.

4

CA Workload Automation SE abends with a U0750. If the I/O error is permanent, it is necessary to move the Log data set. When the error has been corrected, CA Workload Automation SE should be reinitialized using the emergency restart (TYPE=ERST) procedure.