CA-7.A - CA-7.X Messages › CA-7.V601 Through CA-7.V636 Messages › CA-7.V614
CA-7.V614
s mmmm (dddd) OUT OF SPACE ON VSAM PUT FOR DATA TYPE xxxx
Reason:
An output operation detected insufficient space where xxxx is the type of data being output.
This message is:
- Nonrollable until CA Workload Automation SE terminates.
- Issued once per data type.
- Followed by messages CA-7.V613 that identifies the caller and CA-7.V636 which identifies the data set and the key of the failing request.
Action:
We recommend the following steps:
- Bring down CA Workload Automation SE.
- Back up the database.
- Increase the space allocated to file noted in message CA-7.V636.
- Reload the database.
Note: If IDCAMS is used for backup and reload, be sure you adjust the DBPARMS definition to match what was done with IDCAMS.