Previous Topic: Field DescriptionsNext Topic: Reprinting Output Management Bundles


Print Output Parameters

The Print Attribute panel and the CA Deliver Reprint Attributes panel are displayed with default data in the fields.

Default data comes from the print attribute data that was part of the output when it was originally archived. You can delete or modify any of the data in these fields.

To display a complete list of print attributes, enter the O input command ( or OUT or OUTPUT) on the Print Attributes panel or the CA Deliver Reprint Attributes panel and press Enter. The Print Output Parameters panel displays.

CA View ALL -------------- Print Output Parameters --------- Row 00001 of 00105 Command ===> Scroll ===> PAGE ID ---> SALESRPT Job ---> SALESRPT Jobid ---> JOB00144 Name Value ----------------------------------------------------------------------------- ADDRESS-1 ADDRESS-2 ADDRESS-3 ADDRESS-4 BUILDING BURST NO CHARS-1 CHARS-2 CHARS-3 CHARS-4 CKPTLINE CKPTPAGE CKPTSEC CLASS 3 COLORMAP COMPACT COMSETUP

The following print attributes can be changed as needed.

ADDRESS-1 to ADDRESS-4

Deliver address lines for the SYSOUT.

You can specify one to four deliver address lines containing up to 60 text characters.

BUILDING

Defines the building identification for the SYSOUT.

You can specify up to 60 text characters for building identification.

BURST

Specifies whether output is to be burst by a 3800 printer.

Valid values are YES and NO.

CHARS-1 to CHARS-4

Defines the 3800-printer character arrangement table names.

CKPTLINE

Specifies the maximum lines in a logical page.

A range of 0 to 32767 can be specified.

CKPTPAGE

Defines the number of logical pages before JES checkpoints the data.

A range of 1 to 32767 can be specified.

CKPTSEC

Defines the number of sections before JES checkpoints the data.

A range of 1 to 32767 can be specified.

CLASS

Defines the SYSOUT class.

COLORMAP

Defines the color translation resource object.

COMPACT

Defines the compaction table to use to send SYSOUT to an SNA terminal.

COMSETUP

Defines the microfiche setup resource.

CONTROL

Specifies line spacing.

Valid values are:

PROGRAM

Indicates that each logical record contains a carriage control character.

SINGLE

Indicates that single spacing is to be used.

DOUBLE

Indicates that double spacing is to be used.

TRIPLE

Indicates that triple spacing is to be used.

COPIES

Defines the number of copies.

Valid values are 1 to 255.

COPYG-1 to COPYG-8

Defines the 3800-printer copy group values.

Valid values are 1 to 255.

DATACK

Specifies how the printer errors are to be handled.

Valid values are:

BLOCK

Indicates that errors are not reported.

UNBLOCK

Indicates that errors are reported.

BLKCHAR

Indicates that print errors are blocked.

BLKPOS

Indicates that data errors are blocked.

DEPT

Defines the department identification for the SYSOUT.

You can specify up to 60 text characters for department identification.

DEST

Defines the printer destination.

The following values are valid:

See the section Identifying Printer Devices earlier in this chapter for explanations of each destination type.

DPAGELBL

Specifies whether the security label is to be output.

Valid values are YES and NO.

DUPLEX

Specifies whether the report is printed on one or both sides of the paper.

Valid values are:

NO

Prints on one side only.

NORMAL

Rotates the physical page about the Y axis; this permits binding to occur on the long side of the sheet.

TUMBLE

Rotates the physical page about the X axis; this permits binding to occur on the short side of the sheet.

FCB

Defines the name of the forms control image.

FLASH

Defines an optional forms flash overlay name for the 3800 printer.

FLASH COUNT

Defines an optional flash count for the 3800 printer.

Valid values are 1 to 255.

FORM

Defines the forms name.

FORMDEF

Defines the name of the form definition to be used to print the SYSOUT with the 3800 printing subsystem.

FORMLEN

Defines the length and unit of measurement of the form.

FSSDATA

Defines the Functional Subsystem data.

You can specify up to 127 characters for functional subsystem data.

HOLD

Specifies whether output is to be placed on a held queue.

Valid values are YES and NO.

INTRAY

Defines the printer input tray.

A range of 1 to 255 can be specified.

IPDEST

Defines the TCP/IP routing designation.

You can specify up to 124 characters of TCP/IP routing information.

LINECT

Defines the number of lines to print per page.

MODIFY

Defines the 3800 copy modification module name.

MODIFY TRC

Defines the 3800 copy modification module table reference character.

Valid values are 0 to 3.

NAME

Defines the name that is to be printed on output separator pages.

You can specify up to 60 text characters for the name.

NOTIFY-1 to NOTIFY-4

Specifies up to four print notification message destinations.

OFFSETXB

Specifies X offset of logical page origin for the back side of the paper.

OFFSETXF

Specifies X offset of logical page origin for the front side of the paper.

OFFSETYB

Specifies Y offset of logical page origin for the back side of the paper.

OFFSETYF

Specifies Y offset of logical page origin for the front side of the paper.

OPTCDJ

Specifies whether the SYSOUT records are to contain table reference characters.

Valid values are YES and NO.

OUTBIN

Defines the output bin ID.

OUTDISP

A range of 1 to 65535 can be specified.

OUTDISPA

Specifies the normal and abnormal output disposition.

Valid values are:

HOLD

Indicates that the SYSOUT is not printed until it is released.

KEEP

Indicates that the SYSOUT is printed but not immediately purged.

LEAVE

Indicates that the SYSOUT is not printed until it is released and not immediately purged once it is printed.

PURGE

Indicates that the SYSOUT is deleted and not printed.

WRITE

Indicates that the SYSOUT is printed and purged.

OVERLAYB

Specifies medium overlay for back side of paper.

OVERLAYF

Specifies medium overlay for front side of paper.

PAGEDEF

Defines the name of the page definition to be used to print the SYSOUT with the 3800 printing subsystem.

Note: You cannot use this field if you are printing with the P command.

PIMSG

Specifies whether messages from a functional subsystem should be printed.

Valid values are YES and NO.

PIMSG COUNT

Specifies the message threshold; this is the point at which the system will cancel printing.

A range of 1 to 999 can be specified.

PORTNO

Defines the TCP port number where FSS connects to the printer.

A range of 1 to 65535 can be specified.

PRMODE

Defines the process mode to be used to print the SYSOUT with the 3800 printing subsystem.

PRTERROR

Defines the action to take when there is a print error.

Valid values are:

DEFAULT

Take a standard action when a terminating error occurs during printing.

QUIT

Release the SYSOUT when a terminating error occurs during printing.

HOLD

Place the SYSOUT in a held status when a terminating error occurs during printing.

PRTOPTNS

Defines the named entity of print options for FSS.

PRTQUEUE

Defines a target print queue for FSS.

You can specify up to 127 characters for print queue.

PRTY

Assigns a selection priority to the job.

Valid values are 0 to 255.

RESFMT

Defines the resolution that is used to format the print.

Valid values are:

P240

Indicates 240 pels per inch resolution.

P300

Indicates 300 pels per inch resolution.

RETAINF

Defines the failed transmission retain time.

Valid values are hhhh:mm:ss or FOREVER.

RETAINS

Defines the successful transmission retain time.

Valid values are hhhh:mm:ss or FOREVER.

RETRYL

Defines the maximum number of transmission retries.

RETRYT

Defines the length of time to wait between retries.

ROOM

Defines a room identification.

You can specify up to 60 text characters for room identification.

SYSAREA

Specifies whether the system should reserve a system area on each page of output.

Valid values are YES and NO.

TITLE

Defines a title identification.

You can specify up to 60 text characters for text identification.

UCS

Defines the name of the special character set.

The valid value is 1.

USERDATA1 to USERDATA16

Defines 1 to 16 user data lines that can contain up to 60 text characters for the SYSOUT.

WRITER

Defines the external writer name.

This attribute is omitted if an asterisk ("*") is entered in this field.