Previous Topic: DELETENext Topic: EXTRACT


EPRINT

The CA Deliver-to-CA View interface provides a function that is invoked by the EPRINT control statement to print reports archived directly from CA Deliver.

Syntax:

/EPRINT  ACIFRES=Y|N
         ADDRESS=('text'…) 
         BANNER=xxxxxxxx
         BUILDING='text'
         BURST=Y|N
         CHARS=(xxxx xxxx xxxx xxxx)
         CKPTLINE=nnnnn
         CKPTPAGE=nnnnn
         CKPTSEC=nnnnn
         CLASS=x
         COLORMAP=xxxxxxxx
         COMPACT=xxxxxxxx
         COMSETUP=xxxxxxxx
         CONTROL=PROGRAM|SINGLE|DOUBLE|TRIPLE
         COPIES=x
         COPYG=(nnn nnn nnn nnn nnn nnn nnn nnn)
         DATACK=BLOCK|UNBLOCK|BLKCHAR|BLKPOS
         DEPT='text'
         DEST={destid.userid|subsysid.destid}
         DIST=((distid distid …)/dest/writer (distid distid …)/dest/writer …)
         DPAGELBL=Y|N
         DUPLEX=NO|NORMAL|TUMBLE
         FCB=xxxx
         FLASH=(xxxx nnn)
         FORM=xxxxxxxx
         FORMDEF=xxxxxx
         FORMLEN=nn[.mmm]IN|CM
         FSSDATA='data'
         GEN=nnnnn
         HOLD=Y|N
         ID=id
         INDEX=xxxxxxxx
         INST=('text' 'text'...)
         INTRAY=nnn
         IPDEST=ipdest
         LINECT=nnn
         MODIFY=(xxxx n)
         NAME='text'
         NOTIFY=(node.userid …)
         OFFSETXB=mmm[.nnn]IN|CM|MM|PELS|POINTS
         OFFSETXF=mmm[.nnn]IN|CM|MM|PELS|POINTS
         OFFSETYB=mmm[.nnn]IN|CM|MM|PELS|POINTS
         OFFSETYF=mmm[.nnn]IN|CM|MM|PELS|POINTS
         OPTCDJ=Y|N
         OUTBIN=nnnnn
         OUTDISP=(ndisp,adisp)
         OUTPUT=name
         OVERLAYB=xxxxxxxx
         OVERLAYF=xxxxxxxx
         PAGE=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)
         PAGEDEF=xxxxxx
         PIMSG=(Y|N,nnn)
         PORTNO=nnnnn
         PRMODE=xxxxxxxx
         PRSET=xxxxxxx
         PRTERROR=DEFAULT|QUIT|HOLD
         PRTOPTNS=xxxxxxxxxxxxxxxx
         PRTQUEUE='queue'
         PRTY=nnn
         RECORD=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)
         RESFMT=P240|P300        
         RETAINF=hhhh:mm:ss|FOREVER
         RETAINS=hhhh:mm:ss|FOREVER
         RETRYL=nnn
         RETRYT=hhhh:mm:ss
         ROOM='text'
         SELECT=xxxxxxxx
         SEQ=nnnnn
         SYSAREA=Y|N
         TFILTER=xxxxxxxx
         THRESHLD=nnnnnnnn
         TITLE='text'       
         TVIEW=xxxxxxxx
         UCS=xxxx
         USERDATA=('text' …)
         USERLIB=(lib …)
         VIEW=(nnn,viewid,userid)
         WRITER=xxxxxxxx

where:

ACIFRES=Y|N

Specifies whether ACIF AFP resources can be included in the print data stream. This parameter defaults to the value set in SARINIT.

ADDRESS=('text' …)

Specifies deliver address lines for the SYSOUT.

You can specify 1 to 4 deliver address lines that contain up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.

BANNER=xxxxxxxx

Specifies an optional model banner page name to be used to override the one defined for the report in the CA Deliver database.

BUILDING='text

Specifies the building identification for the SYSOUT. You can specify up to 60 text characters for building identification.

BURST=Y|N

Specify Y or N to indicate whether the report destined for the 3800 needs to be burst.

CHARS=(xxxx xxxx xxxx xxxx)

Specifies an optional set of character arrangement table names for the 3800 printer to override the ones used to print the report.

A value of 1 to 4 names separated by one or more blanks and/or commas and enclosed in parentheses can be specified.

CKPTLINE=nnnnn

Specifies the maximum lines in a logical page. A range of 0 to 32767 can be specified.

CKPTPAGE=nnnnn

Specifies the number of logical pages before JES checkpoints data. A range of 1 to 32767 can be specified.

CKPTSEC=nnnnn

Specifies the number of sections before JES checkpoints data. A range of 1 to 32767 can be specified.

CLASS=x

Specifies an optional class to override the one used to print the report.

COLORMAP=xxxxxxxx

Specifies the color translation resource object.

COMPACT=xxxxxxxx

Specifies the compaction table for sending SYSOUT to SNA terminal.

COMSETUP=xxxxxxxx

Specifies the microfiche setup resource.

CONTROL=value

Specifies line spacing. Valid values are:

PROGRAM

Indicates each logical record contains a carriage control character.

SINGLE

Indicates single spacing.

DOUBLE

Indicates double spacing.

TRIPLE

Indicates triple spacing.

COPIES=Y|N

Specify Y or N to indicate whether the copies value is to be used when printing the report for the report recipients.

COPYG=(nnn nnn nnn nnn nnn nnn nnn nnn)

Specifies an optional set of copy groups for the 3800 printer to override the ones used to print the report.

A value of one to eight copy groups separated by one or more blanks and/or commas and enclosed in parentheses can be specified. Each copy group value must be in the range of 1 to 255.

DATACK=value

Specifies how printer errors are to be handled. Valid values are:

BLOCK

Indicates errors are not reported.

UNBLOCK

Indicates errors are reported.

BLKCHAR

Indicates print errors are blocked.

BLKPOS

Indicates data errors are blocked.

DEPT='text'

Indicates department identification for the SYSOUT. You can specify up to 60 text characters for department identification.

DEST={destid.userid|subsysid.destid}

Specifies the destination to which to print the index data, using one of these formats:

Note: For details about printing to CA Spool, see the “Printing Output” chapter in the User Guide.

DIST=((distid distid)/dest/writer (distid distid/dest/writer)

Specifies an optional, complete definition of distribution specifications to override the one defined for the report in the CA Deliver database.

Specify a list of distribution identifiers or groups of distribution identifiers. A group of distribution identifiers consists of a list of distribution identifiers separated by one or more blanks and/or commas and enclosed in parentheses.

Note: If distid contains an embedded blank, parenthesis, quote, or a comma, enclose it in quotes (single or double). Any quote within the Dist-ID must be entered as a pair of quotes because a non-paired quote ends the ID; for example, if the value is JIM’S DESK, enter it as ‘JIM’’S DESK’ or "JIM’S DESK".

Only one copy of the report is written to spool for a group. The model banner page for the group then references all the distribution identifiers in the group.

An optional remote print destination and writer name can be specified as follows:

Follow the distribution identifier or group with a slash (/), the destination with another slash (/), and the writer name. The destination can be a synonym created using the online DEFine DEVice command.

DPAGELBL=Y|N

Specifies whether a security label is to be output.

DUPLEX=value

Specifies whether the report is printed on one or both sides of the paper. Valid values are:

NO

Prints on one side only.

NORMAL

Rotates the physical page about the Y axis, which allows for binding on the long side of the sheet.

TUMBLE

Rotates the physical page about the X axis, which allows for binding on the short side of the sheet.

FCB=xxxx

Specifies an optional forms control image to override the one used to print the report.

FLASH=(xxxx nnn)

Specifies an optional forms flash overlay name and flash count for the 3800 printer to override those used to print the report.

The forms flash overlay name and flash count are separated by one or more blanks and/or commas and are enclosed in parentheses.

FORM=xxxxxxxx

Specifies an optional forms name to override the one used to print the report.

FORMDEF=xxxxxx

Specifies a library member that contains statements to control printing of the SYSOUT data on the 3800 printer.

The statements can specify overlay forms, page location for overlays, and page format suppressions that can be activated.

FORMLEN=nn[.mmm]IN|CM

Specifies length and unit of measurement of the form.

FSSDATA='data'

Specifies Functional Subsystem data. You can specify up to 127 characters for functional subsystem data.

GEN=nnnnn

Specifies the absolute or relative number of the generation of the report to be printed.

If omitted, the most recently archived report for the report identifier is printed.

HOLD=Y|N

Specifies whether the report is to be placed on the held queue for printing. If omitted, HOLD=N is assumed.

ID=id

Specifies the SYSOUT ID/report identifier of the group to be printed. You can specify 1 to 32 characters for ID.

Note: If the id contains embedded blanks, commas, equal signs, parentheses, or quotes, it must be enclosed in quotes (single or double).. Any quotes in Report-id must be entered as a pair of quotes because a non-paired quote ends the ID. For example, if the value is JIM’S REPORT, it must be entered as ‘JIM’’S REPORT’ or "JIM’S REPORT". This parameter is required.

INDEX=xxxxxxxx

Specifies the index value associated with this print request.

INST=('text' 'text')

Specifies an optional, complete set of special instructions to override the set defined for the report in the CA Deliver database.

Multiple lines of instruction text can be specified as a list of the text lines separated by blanks and/or commas and enclosed in parentheses.

A single line of text must be enclosed within single quotation marks; a single quotation mark within the text itself must be represented by two, contiguous single quotation marks.

INTRAY=nnn

Specifies the printer input tray. A range of 1 to 255 can be specified.

IPDEST=ipdest

Specifies the TCP/IP routing designation. You may specify up to 124 characters of TCP/IP routing information.

LINECT=nnn

Specifies the number of lines to print per page.

MODIFY=(xxxx n)

Specifies an optional copy modification module name and table reference character for the 3800 printer to override those used to print the report.

The copy modification module name and table reference character are separated by one or more blanks and/or commas and are enclosed in parentheses.

The table reference character can have a value of 0 to 3.

NAME='text'

Specifies the name to be printed on output separator pages. You can specify up to 60 text characters for the name.

NOTIFY=(node.userid …)

Specifies a print notification message destination. You can specify up to four destinations for the print notification message.

OFFSETXB=mmm[.nnn]IN|CM|MM|PELS|POINTS

Specifies X offset of logical page origin for the back side of the paper.

OFFSETXF=mmm[.nnn]IN|CM|MM|PELS|POINTS

Specifies X offset of logical page origin for the front side of the paper.

OFFSETYB=mmm[.nnn]IN|CM|MM|PELS|POINTS

Specifies Y offset of logical page origin for the back side of the paper.

OFFSETYF=mmm[.nnn]IN|CM|MM|PELS|POINTS

Specifies Y offset of logical page origin for the front side of the paper.

OPTCDJ=Y|N

Specify Y or N to indicate whether the report records contain table reference characters for the 3800 printer.

OUTBIN=nnnnn

Specifies the output bin ID. A range of 1 to 65535 can be specified.

OUTDISP=(ndisp,adisp)

Specifies the normal and abnormal output disposition. Valid values are:

HOLD

Indicates SYSOUT is not printed until it is released.

KEEP

Indicates SYSOUT is printed but not immediately purged.

LEAVE

Indicates SYSOUT is not printed until it is released and not immediately purged once printed.

PURGE

Indicates SYSOUT is deleted without printing.

WRITE

Indicates SYSOUT is printed and purged.

OUTPUT=xxxxxxxx

Specifies the name of the output statement to be used for printing the SYSOUT group.

This parameter overrides the specifications of the FORMDEF, LINECT, PAGEDEF, PRMODE, and possibly, FORM parameters. The parameter (xxxxxxxx) data is specified as follows:

name

stepname.name.

stepname.procstepname.name

An asterisk can precede the parameter data to match the JCL specification of the OUTPUT parameter.

OVERLAYB=xxxxxxxx

Specifies medium overlay for back side of paper.

OVERLAYF=xxxxxxxx

Specifies medium overlay for front side of paper.

PAGE=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)

Specifies 1 to 9 page numbers and/or ranges of pages to be printed.

The page numbers and/or ranges of pages are separated by one or more blanks and/or commas and are enclosed in parentheses. A range of pages is specified as two page numbers separated by a colon.

If both PAGE and RECORD are omitted, the entire SYSOUT group is printed.

PAGEDEF=xxxxxx

Specifies a library member containing statements to control the printing of the SYSOUT data on the 3800 printer.

The statements can specify logical page length, width, fonts, and page segments.

PIMSG=(Y|N,nnn)

Specifies whether messages from a functional subsystem are to be printed and the message threshold where the system cancels printing.

PORTNO=nnnnn

Specifies the TCP port number at which FSS connects to the printer. A range of 1 to 65535 can be specified.

PRMODE=xxxxxxxx

Specifies the process mode required for printing the SYSOUT group.

PRSET=xxxxxxx

Specifies the name of the printer setup member used to print this report.

PRTERROR=value

Specifies an action for print error. Valid values are:

DEFAULT

Indicates that a standard action is taken when a terminating error occurs during printing.

QUIT

Indicates that the SYSOUT is released when a terminating error occurs during printing.

HOLD

Indicates that the SYSOUT is placed in held status when a terminating error occurs during printing.

PRTOPTNS=xxxxxxxxxxxxxxxx

Specifies the named entity of print options for FSS.

PRTQUEUE='queue'

Specifies a target print queue for FSS. You can specify up to 127 characters for print queue.

PRTY=nnn

Specifies the priority to assign to this print request.

RECORD=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)

Specifies one to nine record numbers and/or ranges of records to be printed

The record numbers and/or ranges of records are separated by one or more blanks and/or commas and are enclosed in parentheses. A range of records is specified as two record numbers separated by a colon.

If both PAGE and RECORD are omitted, the entire SYSOUT group is printed.

RESFMT=P240|P300

Specifies the resolution used to format the print. Valid values are:

P240

Indicates 240 pels per inch resolution.

P300

Indicates 300 pels per inch resolution.

RETAINF=hhhh:mm:ss|FOREVER

Specifies the failed transmission retain time.

RETAINS=hhhh:mm:ss|FOREVER

Specifies the successful transmission retain time.

RETRYL=nnn

Specifies the maximum number of transmission retries.

RETRYT=hhhh:mm:ss

Specifies the length of time to wait between retries.

ROOM='text'

Specifies a room identification. You can specify up to 60 text characters for room identification.

SELECT=xxxxxxxx

Specifies the page separation index value for selecting pages to print.

If the value contains any of the special characters: blank, comma, or single quote, the index value must be enclosed within single or double quotes.

SEQ=nnnnn

Specifies the absolute or relative SYSOUT sequence number of the report to be printed.

EX: SEQ=-1

The second most recently archived SYSOUT is processed regardless of its generation and sequence number.

EX: SEQ=-2

The third most recently archived SYSOUT is processed regardless of its generation and sequence number.

SYSAREA=Y|N

Specifies whether the system is to reserve a system area on each page of output.

TFILTER=xxxxxxxx

Specifies the temporary filter name used to print this report where the format is yyydddseq#.

THRESHLD=nnnnnnnn

Specifies the maximum size of a SYSOUT data set. A range of 1 to 99999999 can be specified.

TITLE='text'

Specifies a title identification. You can specify up to 60 text characters for text identification.

TVIEW=xxxxxxxx

Specifies the temporary view name used to print this report where the format is yyydddseq#.

UCS=xxxx

Specifies an optional, special character set name to override the one used to print the report.

USERDATA=('text' …)

Specifies user data for the SYSOUT. You can specify 1 to 16 user data lines containing up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.

USERLIB=(lib …)

Specifies up to eight libraries containing APF resources.

VIEW=(nnn, viewid,userid)

Specifies the view format to use to print the report, where:

nnn

View number (1 to 255).

viewed

Optionally specifies the ID of a public, private, or global view.

Note: If the id contains embedded blanks, commas, equal signs, parentheses, or quotes, it must be enclosed in quotes (single or double). Any quotes in Report-id must be entered as a pair of quotes because a non-paired quote ends the ID. For example, if the value is JIM’S REPORT, it must be entered as ‘JIM’’S REPORT’ or "JIM’S REPORT".

userid

Optionally specifies the user ID for private view.

WRITER=xxxxxxxx

Specifies the external writer name to be used for printing the SYSOUT group.

Notes: