The CA Deliver-to-CA View interface provides a function that is invoked by the EPRINT control statement to print reports archived directly from CA Deliver.
Syntax:
/EPRINT ACIFRES=Y|N
ADDRESS=('text'…)
BANNER=xxxxxxxx
BUILDING='text'
BURST=Y|N
CHARS=(xxxx xxxx xxxx xxxx)
CKPTLINE=nnnnn
CKPTPAGE=nnnnn
CKPTSEC=nnnnn
CLASS=x
COLORMAP=xxxxxxxx
COMPACT=xxxxxxxx
COMSETUP=xxxxxxxx
CONTROL=PROGRAM|SINGLE|DOUBLE|TRIPLE
COPIES=x
COPYG=(nnn nnn nnn nnn nnn nnn nnn nnn)
DATACK=BLOCK|UNBLOCK|BLKCHAR|BLKPOS
DEPT='text'
DEST={destid.userid|subsysid.destid}
DIST=((distid distid …)/dest/writer (distid distid …)/dest/writer …)
DPAGELBL=Y|N
DUPLEX=NO|NORMAL|TUMBLE
FCB=xxxx
FLASH=(xxxx nnn)
FORM=xxxxxxxx
FORMDEF=xxxxxx
FORMLEN=nn[.mmm]IN|CM
FSSDATA='data'
GEN=nnnnn
HOLD=Y|N
ID=id
INDEX=xxxxxxxx
INST=('text' 'text'...)
INTRAY=nnn
IPDEST=ipdest
LINECT=nnn
MODIFY=(xxxx n)
NAME='text'
NOTIFY=(node.userid …)
OFFSETXB=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETXF=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETYB=mmm[.nnn]IN|CM|MM|PELS|POINTS
OFFSETYF=mmm[.nnn]IN|CM|MM|PELS|POINTS
OPTCDJ=Y|N
OUTBIN=nnnnn
OUTDISP=(ndisp,adisp)
OUTPUT=name
OVERLAYB=xxxxxxxx
OVERLAYF=xxxxxxxx
PAGE=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)
PAGEDEF=xxxxxx
PIMSG=(Y|N,nnn)
PORTNO=nnnnn
PRMODE=xxxxxxxx
PRSET=xxxxxxx
PRTERROR=DEFAULT|QUIT|HOLD
PRTOPTNS=xxxxxxxxxxxxxxxx
PRTQUEUE='queue'
PRTY=nnn
RECORD=(nnn nnn nnn nnn nnn nnn nnn nnn nnn)
RESFMT=P240|P300
RETAINF=hhhh:mm:ss|FOREVER
RETAINS=hhhh:mm:ss|FOREVER
RETRYL=nnn
RETRYT=hhhh:mm:ss
ROOM='text'
SELECT=xxxxxxxx
SEQ=nnnnn
SYSAREA=Y|N
TFILTER=xxxxxxxx
THRESHLD=nnnnnnnn
TITLE='text'
TVIEW=xxxxxxxx
UCS=xxxx
USERDATA=('text' …)
USERLIB=(lib …)
VIEW=(nnn,viewid,userid)
WRITER=xxxxxxxx
where:
Specifies whether ACIF AFP resources can be included in the print data stream. This parameter defaults to the value set in SARINIT.
Specifies deliver address lines for the SYSOUT.
You can specify 1 to 4 deliver address lines that contain up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.
Specifies an optional model banner page name to be used to override the one defined for the report in the CA Deliver database.
Specifies the building identification for the SYSOUT. You can specify up to 60 text characters for building identification.
Specify Y or N to indicate whether the report destined for the 3800 needs to be burst.
Specifies an optional set of character arrangement table names for the 3800 printer to override the ones used to print the report.
A value of 1 to 4 names separated by one or more blanks and/or commas and enclosed in parentheses can be specified.
Specifies the maximum lines in a logical page. A range of 0 to 32767 can be specified.
Specifies the number of logical pages before JES checkpoints data. A range of 1 to 32767 can be specified.
Specifies the number of sections before JES checkpoints data. A range of 1 to 32767 can be specified.
Specifies an optional class to override the one used to print the report.
Specifies the color translation resource object.
Specifies the compaction table for sending SYSOUT to SNA terminal.
Specifies the microfiche setup resource.
Specifies line spacing. Valid values are:
Indicates each logical record contains a carriage control character.
Indicates single spacing.
Indicates double spacing.
Indicates triple spacing.
Specify Y or N to indicate whether the copies value is to be used when printing the report for the report recipients.
Specifies an optional set of copy groups for the 3800 printer to override the ones used to print the report.
A value of one to eight copy groups separated by one or more blanks and/or commas and enclosed in parentheses can be specified. Each copy group value must be in the range of 1 to 255.
Specifies how printer errors are to be handled. Valid values are:
Indicates errors are not reported.
Indicates errors are reported.
Indicates print errors are blocked.
Indicates data errors are blocked.
Indicates department identification for the SYSOUT. You can specify up to 60 text characters for department identification.
Specifies the destination to which to print the index data, using one of these formats:
Note: For details about printing to CA Spool, see the “Printing Output” chapter in the User Guide.
Specifies an optional, complete definition of distribution specifications to override the one defined for the report in the CA Deliver database.
Specify a list of distribution identifiers or groups of distribution identifiers. A group of distribution identifiers consists of a list of distribution identifiers separated by one or more blanks and/or commas and enclosed in parentheses.
Note: If distid contains an embedded blank, parenthesis, quote, or a comma, enclose it in quotes (single or double). Any quote within the Dist-ID must be entered as a pair of quotes because a non-paired quote ends the ID; for example, if the value is JIM’S DESK, enter it as ‘JIM’’S DESK’ or "JIM’S DESK".
Only one copy of the report is written to spool for a group. The model banner page for the group then references all the distribution identifiers in the group.
An optional remote print destination and writer name can be specified as follows:
Follow the distribution identifier or group with a slash (/), the destination with another slash (/), and the writer name. The destination can be a synonym created using the online DEFine DEVice command.
Specifies whether a security label is to be output.
Specifies whether the report is printed on one or both sides of the paper. Valid values are:
Prints on one side only.
Rotates the physical page about the Y axis, which allows for binding on the long side of the sheet.
Rotates the physical page about the X axis, which allows for binding on the short side of the sheet.
Specifies an optional forms control image to override the one used to print the report.
Specifies an optional forms flash overlay name and flash count for the 3800 printer to override those used to print the report.
The forms flash overlay name and flash count are separated by one or more blanks and/or commas and are enclosed in parentheses.
Specifies an optional forms name to override the one used to print the report.
Specifies a library member that contains statements to control printing of the SYSOUT data on the 3800 printer.
The statements can specify overlay forms, page location for overlays, and page format suppressions that can be activated.
Specifies length and unit of measurement of the form.
Specifies Functional Subsystem data. You can specify up to 127 characters for functional subsystem data.
Specifies the absolute or relative number of the generation of the report to be printed.
If omitted, the most recently archived report for the report identifier is printed.
Specifies whether the report is to be placed on the held queue for printing. If omitted, HOLD=N is assumed.
Specifies the SYSOUT ID/report identifier of the group to be printed. You can specify 1 to 32 characters for ID.
Note: If the id contains embedded blanks, commas, equal signs, parentheses, or quotes, it must be enclosed in quotes (single or double).. Any quotes in Report-id must be entered as a pair of quotes because a non-paired quote ends the ID. For example, if the value is JIM’S REPORT, it must be entered as ‘JIM’’S REPORT’ or "JIM’S REPORT". This parameter is required.
Specifies the index value associated with this print request.
Specifies an optional, complete set of special instructions to override the set defined for the report in the CA Deliver database.
Multiple lines of instruction text can be specified as a list of the text lines separated by blanks and/or commas and enclosed in parentheses.
A single line of text must be enclosed within single quotation marks; a single quotation mark within the text itself must be represented by two, contiguous single quotation marks.
Specifies the printer input tray. A range of 1 to 255 can be specified.
Specifies the TCP/IP routing designation. You may specify up to 124 characters of TCP/IP routing information.
Specifies the number of lines to print per page.
Specifies an optional copy modification module name and table reference character for the 3800 printer to override those used to print the report.
The copy modification module name and table reference character are separated by one or more blanks and/or commas and are enclosed in parentheses.
The table reference character can have a value of 0 to 3.
Specifies the name to be printed on output separator pages. You can specify up to 60 text characters for the name.
Specifies a print notification message destination. You can specify up to four destinations for the print notification message.
Specifies X offset of logical page origin for the back side of the paper.
Specifies X offset of logical page origin for the front side of the paper.
Specifies Y offset of logical page origin for the back side of the paper.
Specifies Y offset of logical page origin for the front side of the paper.
Specify Y or N to indicate whether the report records contain table reference characters for the 3800 printer.
Specifies the output bin ID. A range of 1 to 65535 can be specified.
Specifies the normal and abnormal output disposition. Valid values are:
Indicates SYSOUT is not printed until it is released.
Indicates SYSOUT is printed but not immediately purged.
Indicates SYSOUT is not printed until it is released and not immediately purged once printed.
Indicates SYSOUT is deleted without printing.
Indicates SYSOUT is printed and purged.
Specifies the name of the output statement to be used for printing the SYSOUT group.
This parameter overrides the specifications of the FORMDEF, LINECT, PAGEDEF, PRMODE, and possibly, FORM parameters. The parameter (xxxxxxxx) data is specified as follows:
stepname.name.
An asterisk can precede the parameter data to match the JCL specification of the OUTPUT parameter.
Specifies medium overlay for back side of paper.
Specifies medium overlay for front side of paper.
Specifies 1 to 9 page numbers and/or ranges of pages to be printed.
The page numbers and/or ranges of pages are separated by one or more blanks and/or commas and are enclosed in parentheses. A range of pages is specified as two page numbers separated by a colon.
If both PAGE and RECORD are omitted, the entire SYSOUT group is printed.
Specifies a library member containing statements to control the printing of the SYSOUT data on the 3800 printer.
The statements can specify logical page length, width, fonts, and page segments.
Specifies whether messages from a functional subsystem are to be printed and the message threshold where the system cancels printing.
Specifies the TCP port number at which FSS connects to the printer. A range of 1 to 65535 can be specified.
Specifies the process mode required for printing the SYSOUT group.
Specifies the name of the printer setup member used to print this report.
Specifies an action for print error. Valid values are:
Indicates that a standard action is taken when a terminating error occurs during printing.
Indicates that the SYSOUT is released when a terminating error occurs during printing.
Indicates that the SYSOUT is placed in held status when a terminating error occurs during printing.
Specifies the named entity of print options for FSS.
Specifies a target print queue for FSS. You can specify up to 127 characters for print queue.
Specifies the priority to assign to this print request.
Specifies one to nine record numbers and/or ranges of records to be printed
The record numbers and/or ranges of records are separated by one or more blanks and/or commas and are enclosed in parentheses. A range of records is specified as two record numbers separated by a colon.
If both PAGE and RECORD are omitted, the entire SYSOUT group is printed.
Specifies the resolution used to format the print. Valid values are:
Indicates 240 pels per inch resolution.
Indicates 300 pels per inch resolution.
Specifies the failed transmission retain time.
Specifies the successful transmission retain time.
Specifies the maximum number of transmission retries.
Specifies the length of time to wait between retries.
Specifies a room identification. You can specify up to 60 text characters for room identification.
Specifies the page separation index value for selecting pages to print.
If the value contains any of the special characters: blank, comma, or single quote, the index value must be enclosed within single or double quotes.
Specifies the absolute or relative SYSOUT sequence number of the report to be printed.
The second most recently archived SYSOUT is processed regardless of its generation and sequence number.
The third most recently archived SYSOUT is processed regardless of its generation and sequence number.
Specifies whether the system is to reserve a system area on each page of output.
Specifies the temporary filter name used to print this report where the format is yyydddseq#.
Specifies the maximum size of a SYSOUT data set. A range of 1 to 99999999 can be specified.
Specifies a title identification. You can specify up to 60 text characters for text identification.
Specifies the temporary view name used to print this report where the format is yyydddseq#.
Specifies an optional, special character set name to override the one used to print the report.
Specifies user data for the SYSOUT. You can specify 1 to 16 user data lines containing up to 60 text characters separated by blanks and/or commas and enclosed in parentheses.
Specifies up to eight libraries containing APF resources.
Specifies the view format to use to print the report, where:
View number (1 to 255).
Optionally specifies the ID of a public, private, or global view.
Note: If the id contains embedded blanks, commas, equal signs, parentheses, or quotes, it must be enclosed in quotes (single or double). Any quotes in Report-id must be entered as a pair of quotes because a non-paired quote ends the ID. For example, if the value is JIM’S REPORT, it must be entered as ‘JIM’’S REPORT’ or "JIM’S REPORT".
Optionally specifies the user ID for private view.
Specifies the external writer name to be used for printing the SYSOUT group.
Notes:
|
Copyright © 2015 CA Technologies.
All rights reserved.
|
|