Previous Topic: User ExitsNext Topic: SMF Type–6 Record for 3800 Printers


SMF Type-6 Records

The product produces special type-6 SMF records for any SYSOUT groups automatically printed by the archival started task when the initialization parameter SMF=YES has been specified. The SARSMF6 macro maps the type-6 SMF record. The format of the type-6 SMF records is as follows:

Offset
(dec.)


Name

Length
(chars.)


Contents

0

SMF6LEN

2

Record length in binary

2

SMF6SEG

2

Segment descriptor

4

SMF6FLG

1

System indicator for VS2 (X'02')

5

SMF6RTY

1

Record type (X'06')

6

SMF6TME

4

Time in binary, in hundredths of a second, that the record was moved to SMF buffer

10

SMF6DTE

4

Date that the record was moved to SMF buffer, in the form 0CYYDDDF where F is the sign

14

SMF6SID

4

System identification (taken from the SID parameter)

18

SMF6JBN

8

Job name

26

SMF6RST

4

Time in binary, in hundredths of a second, that the reader recognized the JOB statement for this job

30

SMF6RSD

4

Date that the reader recognized the JOB statement for this job, in the form 0CYYDDDF where F is the sign

34

SMF6UIF

8

User identification

42

SMF6OWC

1

SYSOUT class

43

SMF6WST

4

Start time in binary, in hundredths of a second, that CA View printed the SYSOUT

47

SMF6WSD

4

Date that CA View printed the SYSOUT, in the form 0CYYDDDF where F is the sign

51

SMF6NLR

4

Number of lines, in binary, printed for all copies

55

SMF6IOE

1

X'00'

56

SMF6NDS

1

Number of copies printed

57

SMF6FMN

4

Form number

61

SMF6PAD1

1

Section indicator (X'80'-3800 Printing Subsystem section present and X'40'‑Common section present)

62

SMF6SBS

2

Subsystem identification (C'ES')

64

SMF6LN1

2

Length of rest of record, including this field, but not including any additional sections indicated by the SMF6PAD1 field

66

SMF6DCI

1

X'0000'

67

SMF6INDC

1

Indicator bits (X'01' – four-digit job number supplied or X'03' – full job number provided in Common section)

68

SMF6JNM

4

Job number

72

SMF6OUT

8

SYSOUT destination

80

SMF6FCB

4

FCB image identification

84

SMF6UCS

4

UCS image identification

88

SMF6PGE

4

Number of pages, in binary, printed for all copies

92

SMF6RTE

2

X'0000'

94

SMF6RID

32

SYSOUT/Report identifier

126

SMF6ACCT

20

Accounting data