Initialization Parameters › Initialization Parameters › RMSWARN
RMSWARN
Determines how RMORMS reacts to an inactive started task.
- When set to YES, RMORMS issues the RMORRS18 message, but it does not ABEND the job. Normal CA 11 restart processing continues.
- When set to NO, the default, RMORRS18 is issued, and the job does ABEND with code U0004.
This parameter is intended for use when the product is not active. Jobs not defined to CA Deliver need CA 11 processing, and RMORMS is executed to call CA 11 (U11RMS).
Note:
- With RMSWARN=YES, no CA Deliver restart processing is to occur for jobs defined to an inactive CA Deliver.
- To ensure that restart processing happens, set RMSWARN to NO.
Syntax:
RMSWARN=YES/NO
Default: NO
Copyright © 2013 CA.