Previous Topic: A. Examine the MismatchNext Topic: Step 3. Terminate the Run


B. Review the Rulesets Applied During the Run

The Applied Rules panel lists all of the rulesets that you requested to be included in this run: test stream, application, and system. From this display, you can see that the identification criteria was recognized and the rule actions defined to the RUL00001 rule were applied.

Action:

Press PF2 to rotate the display to Expected, which consists of the originally-logged test stream record with the rules applied; to the current view of the test stream record; and to the original test stream record from the originally-logged test stream. When you are finished, press PF3.

----------------------------- APPLIED RULES --------------------------12:47:59 ENTER COMMAND ===> INPUT: TCADS.CCC.ORDERAPP.001 CURRENT RECORD: 6 LINE 1 TO 6 OF 6 B-BROWSE E-EDIT OBJECT TYPE ROW COL LEN OP VALUE FROM THE MODEL SCREEN/DESCRIPTION _ RULESET T/S TCADS.CCC.ORDERAPP.001 _ RULE RUL00001- RELEASE 6.2 TO 6.3 CH APPLIED> _ FLD-RECOG 1 30 23 EQ CAROL'S COOKIES COMPANY______ <RECOGNIZED> _ CHANGED OUT 1 74 1 3_______________________________ <APPLIED> _ VARIABLE OUT 1 7 8 02/11/98________________________ <APPLIED> _ VARIABLE OUT 2 7 8 13:39:48________________________ <APPLIED> F1-HELP F2-ROTATE F3-END F4-RETURN F7-UP F8-DOWN

Result:

You return to the Run Mismatch Options screen. From there, you will terminate the run.