Previous Topic: B. Select from the Primary Options MenuNext Topic: Step 2. Process a Transaction


C. Specify Logging Options for This Session

The Log Options Menu lets you specify whether screens will be logged from your terminal, another terminal, or multiple terminals.

Action:

Type t to capture screens from your terminal only, and press Enter.

---------------------------- LOG OPTIONS MENU -----------------------13:45:12 ENTER COMMAND ===> t T THIS TERMINAL O ANOTHER TERMINAL M MULTIPLE TERMINALS ENTER ONE OF THE ABOVE OPTIONS AND PRESS ENTER TO CONTINUE OR F3 TO END

Result:

CA Verify for CICS displays the Single Terminal Log menu.

Note: You could have bypassed the Log Options Menu by typing L.T on the Primary Options Menu to go directly to the Single Terminal Log Menu.

Action:

Type the following information on the Single Terminal Log Options menu. This menu lets you specify the name for the series of screens — test stream — you are going to log, and options that affect the logging.

The DDNAME, APPLICATION, MEMBER, and VERSION information identify the test stream.

DESCRIPTION

Describes the test stream. Tab to this field and type up to three lines of any meaningful text.

STOP OPTION

Specifies how you will terminate logging. MAN is the default and indicates that you will stop logging manually. You can also specify a PF key, a PA key, or CLEAR. Leave MAN as the default.

PROCESS WITH RULES

Lets you apply a ruleset to this logging session. If Y is typed in this field, a list of available rulesets will appear when you press Enter. These rulesets contain rules that specify user IDs, terminals, or transaction IDs that are to be included or excluded from the test stream. Since you do not wish to apply a ruleset to this logging session, leave N as the default.

TEST STREAM PROTECTION

Limits access to this test stream by other users. Leave this field blank.

LOG INPUT SCREENS ONLY

Logs only input screens from the terminal to the application. Leave N as the default.

EXTEND TEST STREAM

Specifies whether or not this test stream is to be appended to an existing test stream. Leave N as the default.

RULESET NAME

Contains the name of the ruleset to be used during the logging process, if one was selected. This field will be blank.

When your screen is completed like the one shown next, press Enter.

-------------------------- SINGLE TERMINAL LOG ----------------------13:45:18 ENTER COMMAND ===> L1 LOG TEST STREAM AS: DDNAME ===> TCADS APPLICATION ===> ccc MEMBER ===> orderapp VERSION ===> 001 DESCRIPTION ===> carol's cookies company demo program ===> ===> STOP OPTION ===> MAN (MAN, PF__, PA_, OR CLEAR) PROCESS WITH RULES ===> N (Y/N) TEST STREAM PROTECTION ===> (R-READ W-WRITE P-PRINT) LOG INPUT SCREENS ONLY ===> N (Y/N) EXTEND TEST STREAM ===> N (Y/N) RULESET NAME: F1-HELP F3-END F4-RETURN

Result:

CA Verify for CICS clears your screen.