  1. Type 6 on the Add Rules—Rule Actions Menu.

    The Add Rule Actions—Change Field panel is displayed as shown next.

    --------------------ADD RULE ACTIONS - CHANGE FIELD VALUE------------08:23:24 ENTER COMMAND ===> RULE NAME: RUL00001 RULESET NAME: TCADS.CCC.ORDERAPP.001 TEST STREAM NAME: TCADS.CCC.ORDERAPP.001 CHANGED FIELDS: ROW COL LEN ATTR FIELD VALUE __ ___ ___ ____ ______________________________________________________ ______________________________________________________ ______________________________________________________ OUTPUT/INPUT FIELD ===> O ( I=INPUT, O=OUTPUT) F1-HELP F2-PREVIEW F3-END F4-RETURN F9-SELECT

    For instructions on completing a data entry panel and for a description of the RULESET NAME, TEST STREAM, RULE NAME, ROW, COL, and LEN fields, see the section Use the Rules Function Panels.

    ATTR

    Type a field attribute, if the attribute is changing. If the attribute is not changing, leave ATTR blank and CA Verify will default to the original attribute value. Select one of these values for ATTR: U, UM, UH, UHM, UN, UNM, UNH, UNHM, P, PM, PH, PHM, PS, PSM, PSH, PSHM. The meaning of each letter is explained next.

    U

    Unprotected field; can be modified

    P

    Protected field; cannot be modified

    N

    Numeric field; only numeric data can be typed

    S

    Cursor will auto-skip over the field

    H

    High-intensity field

    M

    Field with modified data tag which will be transmitted from the terminal even if the operator makes no entry

    FIELD VALUE

    Type the new value to be used in the field. A value is required.

    INPUT/OUTPUT FIELD

    Indicates whether the value being changed is an input or an output field. The default is Output.

    A completed Add Rule Actions—Change Field Value panel is shown next. This sample shows the value of a field being changed to 7.0.

    ------------------ADD RULE ACTIONS - CHANGE FIELD VALUE--------- ADD SUCCESSFUL ENTER COMMAND ===> RULE NAME: RUL00001 RULESET NAME: TCADS.CCC.ORDERAPP.001 TEST STREAM NAME: TCADS.CCC.ORDERAPP.001 CHANGED FIELDS: ROW COL LEN ATTR FIELD VALUE 02 075 003 ____ 7.0___________________________________________________ ______________________________________________________ ______________________________________________________ OUTPUT/INPUT FIELD ===> O ( I=INPUT, O=OUTPUT) F1-HELP F2-PREVIEW F3-END F4-RETURN F9-SELECT