Previous Topic: 0027ENext Topic: 0029I


0028E

ERROR code INITIALIZING DIRECTORY MINIDISK

Reason:

A problem initializing the CP‑owned volume containing the CP object directory area has occurred. This volume is specified on the DIRECT record in the PRODUCT CONFIG file. The CA VM:Director service virtual machine must have a read/write link to the volume. The possible code values are:

Error Code

Meaning

4

The directory volume is not attached to the CA VM:Director service virtual machine.

8

The device type of the specified volume is not a supported directory device.

12

An I/O error occurred reading the volume label of the directory volume.

16

The volume label does not match the label specified on the DIRECT record in the PRODUCT CONFIG file.

20

The allocation on the directory volume was found to be incorrect or inconsistent.

24

The current directory as indicated by the volume label is not in the currently allocated extent.

28

An FBA volume extent error was detected.

32

No unallocated directory extents were found on the directory volume.

36

The volume containing the CP object directory extent is read‑only.

Initialization fails.

Action:

Make corrections to the PRODUCT CONFIG file or the CA VM:Director directory entry and start CA VM:Director again.