Previous Topic: SPI Equivalents for CEMT ADD and REMOVENext Topic: SPI Equivalents for EXEC CICS ENABLE, DISABLE, EXTRACT, COLLECT STATISTICS


SPI Equivalents for EXEC CICS INQUIRE and SET

The SPI keyword equivalents for EXEC CICS INQUIRE and SET are:

CONNECTI

Contains the four‑character "sysid" used in the TCT (Terminal Control Table), for Intersystem Communication (ISC) or Inter‑region Communication (IRC).

DATASET

The eight‑character name used in the FCT (File Control Table).

FILE

The eight‑character data set name in the FCT.

MODENAME

The eight‑character name for a mode group defined for a specific system connection.

PROGRAM

The eight‑character program name defined in the PPT (Program Control Table).

SYSTEM

Indicates the current values of your system parameters.

TERMINAL

The four‑character terminal name used in the TCT (Terminal Control Table).

TRANSACT

The four‑character transaction name used in the PCT (Program Control Table).