The TIMEREC keyword is required when adding a TIME record to the SDT Record.
To define a new TIME record to the SDT, enter the command:
TSS ADDTO(SDT) TIMEREC(time‑name)
DESCRIPT(descript‑name)
RANGE(hhmm:hhmm,...)
Specifies a time‑name that is user‑defined and can contain letters, numbers or special characters.
Size: 8 characters
Designates an optional user‑description field that is used as a logical name for this record. If the description field contains blanks, you must enclose it in single quotes.
Size: 32 characters
Specifies one, or a series of, entries in the format hhmm:hhmm for the starting and ending times of a range. You can indicate up to 53 ranges per command.
The value for minutes must be 00, 15, 30, or 45 designating a 15 minute block of time. For example, 00 refers to the minutes 00 to 14; therefore, RANGE (1200:1300) signifies 12 noon through 1:14 p.m. If you want noon to 1 p.m., specify RANGE(1200:1245) to designate those four quarter hours.
In addition, the end time must be greater than the start time, and wrapping is not allowed.
Examples: define TIME record
This example specifies 11 p.m. until 1 a.m.:
RANGE(2300:2345,0000:0045)
This example is not valid:
RANGE(2300:0045)
This example adds a TIME record called TEMP1 to the SDT:
TSS ADDTO(SDT) TIMEREC(TEMP1)
This example adds a time period from 1 p.m. to 5 p.m. to the RANGE field of the TIME record called TEMP1 in the SDT:
TSS ADDTO(SDT) TIMEREC(TEMP1)
RANGE(1300:1645)
|