This section contains the following topics:
The TSSCPR utility is a batch utility that gives the user the ability to produce customized reports extracted from the CPF Recovery File.
All scope and administrative authority restrictions are honored by this utility, thereby preventing unauthorized access to the CPF Recovery File.
TSSCPR can only be issued by the MSCA or by an SCA, otherwise the following message is issued:
TSS8081E MUST BE MSCA OR SCA
To execute the TSSCPR utility, an SCA must have or be given the following administrative access:
TSS ADMIN(acid) ACID(REPORT) RESOURCE(REPORT) DATA(authority level(s))
To execute TSSCPR, use the following JCL
//TSSCPR JOB //XTRACT EXEC PGM=TSSCPR //CPFOUT DD DSN=dsname,UNIT=????,VOL=SER=???????? // DISP=(,CATLG,DELETE),SPACE=(TRK,(15,15),RLSE), // DCB=(RECFM=FB,LRECL=4500,BLKSIZE=22500) //CPFFILE DD DSN=cpf.recovery.file.name, DISP=SHR
The following is a description of the DD statements used with TSSCPR:
|
DD Statement |
Description |
|---|---|
|
CPFOUT |
Contains formatted records of information extracted from the CPF Recovery File. |
|
CPFFILE |
Contains the CPF Recovery File. |
The following DCB defaults are used with TSSCPR:
|
DD Statement |
Description |
|---|---|
|
DDNAME |
DCB Defaults |
|
CPFOUT |
DSORG=PS, LRECL=4500, BLKSIZE=22500, RECFM=FB |
The record layout for TSSCPR is as follows:
|
Field Position |
Description |
|---|---|
|
1 to 8 |
Internal Flags |
|
9 to 16 |
Command Destination |
|
17 to 20 |
Internal Flags |
|
21 to 24 |
Record ID 'TCPL' |
|
25 to 43 |
Internal Control Fields |
|
44 to 51 |
ACID name |
|
52 to 148 |
Internal Control Fields |
|
149 to 158 |
Date of Command |
|
159 to 404 |
Internal Control Fields |
|
405 to 406 |
Command Length |
|
407 to 408 |
Internal Flags |
|
409 to 844 |
Command Buffer |
Only the Command Destination, ACID Name and Command Buffer fields can be displayed.
For information on using the TSSREPORT3 facility to produce an CA‑Earl® report from TSSCPR output, see the chapter “Using CA‑EARL”
|
Copyright © 2014 CA Technologies.
All rights reserved.
|
|