Reason:
The logonid record field specified in the GLOBALID FIELD input control statement is defined as a multi-valued field in the CA ACF2 Field Definition Record (ACFFDR) field definitions (@CFDEs). CA ACF2 does not allow a multi-valued, user-defined field to be specified in a GLOBALID FIELD input control statement. Because the field is multi-valued, it cannot be written to the CIA real-time database. The CA ACF2 CIA unload utility terminates.
Specifies the external name of the logonid record field in the GLOBALID FIELD input control statement.
Action:
Ensure that the field name specified in the GLOBALID field input control statement is defined as single-valued in the @CFDE macro included in the ACFFDR module. Run the utility again.
Module:
ACFIRPRM
|
Copyright © 2014 CA Technologies.