You can specify operational characteristics such as security, print features, log class, and SMF record number.
TPX System Options Table Detail Panel Panelid - TEN0108 Command ===> Userid - USR047 Terminal - TPXSYS02 System Options Table: SMRTXA Date - 03/14/03 Time - 08:16:49 Operational Parameters ------------------------ * SMF Record Number 000 Use SMF Monitor DD N * Printer Sharing: Y * Print Banner Page: Y * Log class: * Log Destination ID: * Default LOGO: TEN0003V * Console area: Z * Softcopy unit SYSDA * Softcopy volume: WRK002 * European dates: N TEN0196 Record Count Limit Default: 00025 Maximum 00500 * * You can specify LOGO News on the following two lines (158 characters): this is big news * Can be updated dynamically using the TPX Operator Reload Command PF1=Help PF3=End PF4=Return PF7=Prev PF8=Next "CANCEL" cancel
Notes:
A user may override the Default value on the TEN0196 screen up to the Maximum value.
Valid values are 00000 through 65535. It defaults to 00025. A value of 00000 means that all records are to be presented. Allowing a 00000 value can cause severe performance degradations on large complexes, including U0032 abends.
A user may not be able to display the number of users beyond the Maximum value on the TEN0196 screen.
Valid values are 00000 through 65535. It defaults to 00500. A value of 00000 means that all records are to be presented. Allowing a 00000 value can cause severe performance degradations on large complexes, including U0032 abends.
|
Copyright © 2013 CA.
All rights reserved.
|
|