Previous Topic: CAIN1701—CAIN2000Next Topic: CAIN2501—CAIN3000


CAIN2301—CAIN2500

CAIN2301

ENTER data or CLEAR to exit from menu.

Reason:

No data has been entered on the menu screen.

Action:

Enter data or Clear to exit from menu.

CAIN2302

PROG, TRAN, or TERM names not allowed for system‑wide functions.

Reason:

This was a restriction in CA InterTest for CICS version 2.3. These entries are ignored in CA InterTest for CICS version 2.4 and later.

Action:

Erase highlighted entries.

CAIN2303

Programs, transactions, and terminals may not be combined in the same command.

Reason:

Monitoring options can be specified to programs, transactions, or terminals.

Action:

Make separate entries for programs, transactions, and terminals.

CAIN2304

Missing or invalid function number.

Reason:

The entered function is blank or not A through L.

Action:

Enter function A through L or Clear to exit menu.

CAIN2305

Entry Required if interval or queue or terminal entered.

Reason:

A time interval was entered and neither PURGE nor CKPT was selected or, ABP terminal was entered with ABP.

Action:

Enter on/off for desired function.

CAIN2306

Invalid fields highlighted. Correct and press ENTER.

Reason:

The keyword ON/OFF was not entered on the System‑Wide Options Menu.

Action:

Enter the keyword ON or OFF.

CAIN2307

Program, transaction, or terminal entries required for selected function.

Reason:

Function A through H was entered on the function selection menu and no program, transaction or terminal identification was entered.

Action:

Enter at least one program or transaction or terminal identification.

CAIN2308

Invalid function specified. Letters A ‑ N only.

Reason:

No entry was entered on the Function Selection Menu.

Action:

Enter Function A through N or Clear to exit menu.

CAIN2309

Invalid PF key entered.

Reason:

One of the listed PF keys was not entered.

Action:

Choose one of the listed PF keys.

CAIN2310

Enter location in only one format.

Reason:

More than one format has data entered.

Action:

Enter data in only one format.

CAIN2311

One element must be entered for each side of the condition.

Reason:

Data was entered for one side of the condition and not the other on the Conditional Breakpoint Menu.

Action:

Enter data for the other side of the condition.

CAIN2312

Task cannot be both abended and resumed at a new location.

Reason:

Data was entered in the RESUME EXECUTION and the ABEND fields on the Resume Task Execution Menu.

Action:

Select one of these options.

CAIN2313

Task cannot be both abended and single‑stepped.

Reason:

Data was entered in the SINGLE STEP and ABEND fields on the Resume Task Execution Menu.

Action:

Select one of these options.

CAIN2314

Abend and dump options was allowed together.

Reason:

Data was entered in the DUMP and ABEND fields on the Resume Task Execution Menu.

Action:

Select one of these options.

CAIN2315

Command not processed. Correct and resubmit or CLEAR to exit from menus.

Reason:

The generated command was incorrect.

Action:

Contact CA technical support.

CAIN2316

Replaced and replacement program names must both be entered.

Reason:

Data entered in only one side of the replace program name option on the Replacement Options Menu.

Action:

Enter data in both fields.

CAIN2317

Replaced and replacement file names must both be entered.

Reason:

Data was entered in only one side of the Replace file name option on the Replacement Options Menu.

Action:

Enter data in both fields.

CAIN2318

Replaced and replacement Transient Data queue names must both be entered.

Reason:

Data was entered in only one side of the Replace TD queue name option on the Replacement Options Menu.

Action:

Enter data in both fields.

CAIN2319

Replaced and replacement Temporary storage masks must be entered.

Reason:

Data was entered in either the TS selection on TS replacement mask fields on the Replacement Options Menu.

Action:

Enter data in both fields.

CAIN2320

Bypass FROM and TO addresses must both be entered.

Reason:

Data was entered in either the FROM or TO fields of the Bypass Storage Protection option on the Protection Options Menu.

Action:

Enter data in both the FROM and TO fields.

CAIN2321

CSA/CWA offset and length must both be entered.

Reason:

Data was entered in either the Offset or Length fields of the unprotect CSA option or the CWA option on the Protect Options Menu.

Action:

Enter data in both the offset and length fields of the CSA or the CWA options.

CAIN2322

Unprotect address and length must both be entered.

Reason:

Data was entered in either the Address or Length fields of the unprotect main storage area option on the Protection Options Menu.

Action:

Enter data in both fields.

CAIN2323

Protect address and length must both be entered.

Reason:

Data was entered in either the Address or Length fields of the protect main storage area option on the Protection Options Menu.

Action:

Enter data in both fields.

CAIN2324

Enter only one element for each side of condition.

Reason:

Data was entered in more than one field that is used for either the Left Side or the Right Side of the condition on the Conditional Breakpoint Menu.

Action:

Erase the data in all fields but one.

CAIN2325

Invalid operator. Enter EQ, NE, GT, LT, GE, or LE.

Reason:

One of the shown operators was not selected on the Conditional Breakpoint Menu.

Action:

Enter one of the six displayed operators.

CAIN2326

Left side length must be entered

Reason:

A packed decimal literal was entered in the literal field and no length was specified for the left‑side comparison on the Conditional Breakpoint Menu.

Action:

Specify the length for the left‑side condition.

CAIN2327

Right side length must be entered

Reason:

You did not enter a length for the right‑side comparison on the Conditional Breakpoint Menu.

Action:

Specify a length for the right‑side condition.

CAIN2328

Interval required for CKPT or PURGE ON

Reason:

The keyword 'ON' was entered in the PURGE and/or CHKPT fields without an interval specified on the System‑wide Options Menu.

Action:

Specify a time interval.

CAIN2329

Program invalid or NEW option or SYM option not specified

Reason:

Data was entered in the program name field for the NEW and/or SYM option, but no function was selected on the Utility Options menu.

Action:

Select the desired function.

CAIN2330

Program required with NEW or SYM option

Reason:

The SYM or NEW option was selected on the Utility Options Menu, but the associated program name field was left blank.

Action:

Specify a program name.

CAIN2331

Modifier must begin with =, ‑, or .

Reason:

Data was entered in the Optional Offset Field without the proper lead character on the Conditional Breakpoint Menu.

Action:

Start the data with one of the shown characters.

CAIN2332

Program name not found in PPT.

Reason:

The program name entered on the Function Selection Menu or on the Utility Options Menu does not have a PPT entry.

Action:

Enter the name of a valid program. Check the PPT Table.

CAIN2333

Transaction code not found in PCT.

Reason:

The transaction name entered on the Function Selection Menu does not have a PCT entry.

Action:

Enter the name of a valid transaction.

CAIN2334

Terminal name not found in TCT.

Reason:

The terminal identification entered on the Function Selection Menu or the System‑Wide Menu was not found in the TCT.

Action:

Enter a valid terminal identification.

CAIN2335

Next function invalid or missing.

Reason:

Undetermined.

Action:

Contact CA technical support.

CAIN2336

Enter one or more locations or CLEAR to exit.

Reason:

No data was entered on the Breakpoint Locations Menu.

Action:

Enter data or Clear to exit.

CAIN2337

ID numbers cannot be entered in combination with any other fields.

Reason:

Data was entered in one or more of the Identification # fields as well as in a location, loop control number, or terminal identification field on the Remove Breakpoint Menu.

Action:

If ID numbers are entered, they must be the only fields entered on this menu.

CAIN2338

Task number required when not at a breakpoint.

Reason:

No data was entered in the task number field of the Resume Task Execution Menu.

Action:

Enter a valid task number.

CAIN2339

Maximum of 9 locations allowed in one command.

Reason:

More than nine locations were entered on the Breakpoint Locations Menu.

Action:

Enter a maximum of nine locations.

CAIN2340

Paragraph name, Assembler or PL1 label cannot start with a period.

Reason:

Data entered started with a period on the Breakpoint Locations Menu.

Action:

Remove the leading period.

CAIN2341

Breakpoints can be set or removed on only one program

Reason:

Multiple program names were entered together with functions11 through 13 on the Function Selection Menu.

Action:

Specify only one program name.

CAIN2342

Breakpoints cannot be set or removed on a transaction

Reason:

Breakpoints may only be set for a program on the Function Selection Menu.

Action:

Remove the transaction ID, and enter a program name.

CAIN2343

Breakpoints cannot be set or removed on a terminal

Reason:

Breakpoints may only be set on the Function Selection Menu.

Action:

Remove the terminal ID, and enter a program name.

CAIN2344

LIST, SYM or INQ must be chosen when using TD queue

Reason:

A TD queue was chosen to receive a report from the Utility Options Menu, but no keyword was entered.

Action:

Specify LIST, SYM, or INQ in addition to the name of a TD queue.

CAIN2345

.ALL not acceptable for a set option ON command

Reason:

ALL is acceptable only when removing options specified on the Protection Options Menu.

Action:

Press PF8 to return to the Main Menu, then enter R to remove protection.

CAIN2346

.ALL and OFF not acceptable for TON ON command.

Reason:

Invalid data was entered for the Limit monitoring function on the Replacement Options or on the Protection Options Menu.

Action:

Enter a * or a valid terminal identification.

CAIN2347

Dump codes may not begin with the letter "A".

Reason:

A dump code beginning with the letter A was entered on the Resume Task Execution Menu.

Action:

Change the first letter.

CAIN2348

NEW and SWI cannot both be entered. (2.42 Users Only)

Reason:

Both New and SWI functions were selected on the Utility Options Menu.

Action:

Select one or the other function.

CAIN2349

PURGE and CKPT cannot both be entered.

Reason:

Both functions were selected on the System‑Wide Options Menu.

Action:

Select one or the other function.

CAIN2350

.ANY only acceptable for setting conditional breakpoints.

Reason:

Invalid data was entered on the Breakpoint Locations Menu.

Action:

Enter valid data or press PF9.

CAIN2351

S or R indicator is required for this function

Reason:

Function 10 through 22 was entered on the Function Selection Menu, but S (set) or R (remove) was not specified.

Action:

Specify either S or R with these functions.

CAIN2352

Breakpoints cannot be set on program = .ALL or .OPTIONS

Reason:

Breakpoints cannot be set on a global basis.

Action:

Enter a specific program name.

CAIN2353

ALL cannot be requested in combination with individual entries

Reason:

Global options cannot be set with options for specific program names.

Action:

Set options either globally or for individual program names.

CAIN2354

Maximum of 9 entries allowed in one command

Reason:

More than 9 entries were specified on the Breakpoint Locations Menu.

Action:

Enter a maximum of 9 locations.

CAIN2355

STATUS report unavailable ‑ no program, transaction or terminal id

Reason:

Function 30 was requested on the Main Menu, but no program, transaction or terminal ID was entered.

Action:

Enter at least one program name, transaction code or terminal ID when you specify Function 30.

CAIN2356

Breakpoints cannot be set on generic program name

Reason:

A generic value was specified as the program name.

Action:

Enter a specific program name.

CAIN2357

Enter one of the two options for abending task

Reason:

From the Resume Task Menu, the task cannot be abended without specifying an abend code or "XXXX" to abend without a dump.

Action:

Specify either an abend code or 'X' to abend without a dump.

CAIN2358

This feature will be available in general release

Reason:

This feature is not available with this release of CA InterTest for CICS, but is available with the specified release.

Action:

None.

CAIN2359

Composite support not removed. Use function 10 to remove monitoring

Reason:

'R' was entered with Function 23 to remove monitoring from a composite program.

Action:

Use Function 10 to remove monitoring.

CAIN2360

Composite support cannot be set on generic program

Reason:

A generic value was entered as the program name.

Action:

Enter a specific program name.

CAIN2361

Composite support can be set on only one program

Reason:

Multiple program names were entered for Function 23.

Action:

Enter only one program name.

CAIN2362

Program required for selected function

Reason:

The function selected also requires that a program name be specified.

Action:

Specify a program name.

CAIN2363

Composite support cannot be set on a transaction

Reason:

Composite support can only be set on a program.

Action:

Delete the transaction name and specify a program name.

CAIN2364

Composite support cannot be set on a terminal

Reason:

Composite support can only be set for a program.

Action:

Delete the terminal ID, and specify a program name.

CAIN2365

Composite support cannot be set on a subprogram

Reason:

The name specified in the program name field is not the PPT name for the module.

Action:

Specify the PPT of the composite module.

CAIN2366

Functions 13 and 23 are not available under CICS release 1.5

Reason:

Request breakpoints and composite support are not available with this release of CICS.

Action:

None.

CAIN2367

Follow options available under CICS release 1. are ON or NOPPT

Reason:

The FOL= PPTname Option is not supported by this release of CICS.

Action:

Enter either 'ON' or 'NO PPT'.

CAIN2368

# of seconds must be within the range 1‑5

Reason:

The wait amount does not contain a value from 1 through 59.

Action:

Specify the number of seconds from 1 to 59 for the wait amount.

CAIN2369

Enter one of the two options for halting AUTO STEPPING

Reason:

The stop value does not contain the word "CALL" or a numeric value of 1 through 9999.

Action:

Specify the word 'CALL' or enter a value from 1 to 9999.

CAIN2370

The HALT value range is 1 ‑ 999

Reason:

The data entered in the STDA value field is not in the range of 1 through 9999.

Action:

Specify a value of 1 through 9999.

CAIN2371

You must specify a WAIT value with a HALT value

Reason:

Either the wait value or the halt value was left blank.

Action:

Specify valid values for the wait field and the halt field.

CAIN2372

AUTO STEP value must be specified with WAIT and HALT values

Reason:

Either the wait value or the stop value is missing.

Action:

Specify a valid wait value and halt value.

CAIN2373

DB2 cannot be requested in combination with CALLs

Reason:

You attempted to set request breakpoints at both CALLs to DB2 and all IN25UEXI defined CALLs.

Action:

Specify either CALLs or DB2.

CAIN2374

Press Enter to process commands shown, CLEAR to exit.

Reason:

Instructional message.

Action:

Press Enter to execute the displayed commands. Press Clear to exit from this display.

CAIN2375

Press Enter to continue or CLEAR to exit from menu

Reason:

Instructional message.

Action:

Press Enter to continue with the specified function. Press Clear to exit from the menu.

CAIN2376

Invalid PF key entered

Reason:

You entered a PF key that is not available with this screen.

Action:

Specify a valid PF key.

CAIN2377

Transaction terminated, GETMAIN failed

Reason:

There was not enough storage available to complete this request.

Action:

When storage space becomes available, re‑enter your request.

CAIN2378

Command not processed ‑ fatal error

Reason:

An internal error has occurred in CA InterTest for CICS.

Action:

Obtain a dump, and contact CA technical support.

CAIN2379

Menu processing ended

Reason:

You pressed Clear to exit the menu.

Action:

None.

CAIN2380

Internal error ‑ command not processed

Reason:

An internal error has occurred in CA InterTest for CICS.

Action:

Obtain a dump and contact CA technical support.

CAIN2381

Use LIST to set/remove options on duplicate subprograms

Reason:

A duplicate subroutine has been declared for monitoring. The LIST facility or transaction must be used to set/remove options on a duplicate subroutine. The COMPOSITE command must be used in the LIST facility to declare the subprogram's owning load module.

Action:

Use the COMPOSITE command in the LIST facility.

CAIN2390

Terminal identifications and ID numbers cannot both be entered.

Reason:

When ID numbers are entered, no other field may have data on the Remove Locations Menu.

Action:

Remove data from terminal identification fields.

CAIN2391

Invalid special keyword.

Reason:

The Special Keyword Field contains invalid data on the Conditional Breakpoint Menu.

Action:

Press PF1 to obtain a list of valid keywords.

CAIN2392

Invalid message number passed to message module.

Reason:

Undetermined.

Action:

For assistance, contact CA technical support.

CAIN2393

Segmented monitoring can be set for a program only.

Reason:

Segmented monitoring cannot be set for a transaction or terminal ID. It can be set for a program only.

Action:

Specify a valid CICS program name.

CAIN2394

Terminal ID or user ID required for DM option.

Reason:

A specific terminal ID or user ID is required to enable data monitoring.

Action:

Specify a valid terminal ID or user ID.