Even though a task abended, CA SymDump for CICS lets you redisplay the abend that caused the dump at a breakpoint so you can use CA InterTest for CICS to discover the reason for the abend.
To redisplay the abend that caused the dump at a breakpoint
The structured CORE display reveals that TASKNUM contains binary zeros instead of a valid packed decimal value.
CA InterTest ‑ MAIN STORAGE UTILITY ‑ Termid = E024 Starting at Address = 1461A4 Hexadecimal Character 02 TASKNUM 000000 ... 02 TASK‑TEXT 03 TASK‑ID‑NO 000F .. 03 FILLER 40 03 TASK‑MESG E3C8C9E2 40C9E240 C140D4C5 THIS IS A ME E2E2C1C7 C5404040 SSAGE 03 FILLER 40 03 TASK‑DATE 04 TASK‑MM F0F9 09 04 TASK‑SL1 61 / 04 TASK‑DD F1F5 15 04 TASK‑SL2 61 / 04 TASK‑YY F9F3 93 ______________________________________________________________________________ PF1 Help 2 3 End 4 Return 5 6 PF7 Backward 8 Forward 9 Caps Off 10 11 Redisplay 12 Structure CORE='TASKNUM' CORE052 FIELD DOES NOT CONTAIN A VALID PACKED DECIMAL (COMP‑3) VALUE
You can go one step further and see where TASKNUM was defined in your program.
|
Copyright © 2015 CA Technologies.