Messages › Abnormal Condition Messages
Abnormal Condition Messages
ESF995
CHKPTDSx - I/O-ERROR - *** error message ***
Reason:
CA Spool has detected a permanent I/O error on the CHKPTDSx checkpoint data set. *** error message *** is the error description provided by the MVS SYNAD routines. CA Spool is terminated with an error-reason code.
Action:
Save the dump output, then restart CA Spool.
ESF996
I/O-ERROR - *** error message ***
Reason:
CA Spool has detected a permanent I/O error on one of its spool data sets. *** error message *** is the error description provided by the MVS SYNAD routines. CA Spool is terminated with an error-reason code.
Action:
Save the dump output, then restart CA Spool.
ESF997
CHECKPOINT WAS IN PROCESS, CHECKPOINT DATA MAY BE INVALID
Reason:
CA Spool has abended, but the termination routines detected that a checkpoint was in process, and the information in the checkpoint data set may therefore be invalid. Termination continues.
Action:
If CA Spool rejects a restart, notify the systems programmer.
ESF998
CATASTROPHIC ERROR, ESTAE IN CONTROL
Reason:
A system abend has occurred in CA Spool. CA Spool has entered its recovery routines, and will initiate a termination of the system, and produce a dump.
Action:
Restart ESF if possible, or notify the systems programmer. Report the failure and save the dump output.
ESF999
DISASTROUS ERROR, ERROR-CODE = xxxx
Reason:
CA Spool has discovered an incorrectable error in the system.
The following error codes may occur:
- ABND—An ABEND command has been entered
- ACT1—A disastrous error occurred during activity process
- ALL0—The track-allocation routine has detected an invalid track‑allocation‑map control block
- ASM0—No message sequence number could be assigned to a command buffer
- BFR0—A getbuf request failed. Invalid buffer type specified
- BFR1—A freebuf request failed. Invalid buffer type specified
- BFR2—A freebuf request failed. Buffer already on free buffer queue
- CCW0—A request to build a channel program has been rejected because the extent in the MTTR address is invalid
- CCW1—A request to build a channel program has been rejected because the request was not valid
- CKP0—A checkpoint request is being processed, but the requester did not have exclusive access to the file queue
- CH00—Unexpected I/O interrupt (ESFUNC). The checkpoint data set lock is held by an unknown system (ESFCKPT)
- CH01—Permanent I/O error on checkpoint data set
- CH02—Unable to find checkpoint-processor PCB to be dispatched
- CH03—The checkpoint-processor PCB was not on the wait queue
- CH04—The checkpoint-processor PCB was not on the I/O wait queue
- CH05—A checkpoint I/O request has been rejected because the checkpoint data set SCB is in the BUSY state; that is, a previous checkpoint has not been completed
- CH06—The warm start routine in the checkpoint processor has detected an open-file count below zero
- CH07—Unable to start because the file queue could not be rebuilt
- DISP—PCB must complete, support failed
- ESTA—The VTAM interface subtask was unable to establish an ESTAE recovery environment
- FREM—A FREEMAIN of virtual storage request failed
- GENA—The VTAM interface subtask was unable to generate an VTAM ACB
- GETM—An unconditional GETMAIN of virtual storage request failed
- IDX1—The name index initialization failed
- IDX2—The name index termination failed
- INT1—Duplicate node or alias name found during initialization of table index
- INT2—Allocated FBA checkpoint data set too small for the current setup
- INT3—Internal error, invalid #ICEREQ call
- INT4—Initialization of the node name index failed
- IO01—An attempt to start a channel program has been rejected because the extent value was not valid
- IO02—Unexpected I/O interrupt
- IO03—Unable to determine the cause of the I/O interrupt
- IO04—Permanent I/O error on a spool data set
- IO05—Unable to find PCB to be dispatched
- IO06—PCB to be dispatched for the I/O interrupt was not waiting for I/O to complete
- IVSQ—An undefined security request code was passed to the ESFSECU5 security user exit
- LKN1—Invalid $IQLKPNM request received.
- NET1—The active-session-count field dropped below zero
- NET2—A disastrous error has occurred in the network interface
- NET3—The outstanding receive-request-count field dropped below zero
- NET4—The getbuffer routine returned a buffer already on receive-any-queue
- NJE1—Duplicate NJE node name found during initialization
- NJE2—An undefined function code was passed to the #NJEINIT routine
- PR01—An internal error has occurred in a printer node's command-request handler
- PRG0—A track-allocation-map control block has been detected in error by the purge processor
- SAF1—An unrecoverable error has occurred in the SAF interface
- SAV1—Subtask save area invalid
- SAV2—No room in save area
- TRK0—An invalid UTAM spool block was passed to $TRACK
- UCH1—A user ID index release failed
- UIX1—Add user ID to user index failed
- UIX2—Remove user ID from user index failed
- UIX3—Find user ID in user index failed
- WAI1—An internal #WAIT request was issued where R13 did not contain the address of the current processor control block
- XEQ0—A track-allocation map-control block has been detected invalid
- XEQ1 —The open file count has been reduced to a negative value
- XEQ2—A user track-allocation map-control block has been detected invalid during an output (write) operation
- XEQ3—XEQ processor could not obtain storage
- XES1—Read of CKPT Master record from Coupling Facility failed
- XES2—Write of CKPT Master record to Coupling Facility failed
- XES3—Disconnect from Coupling Facility failed
- XFQ1—Internal error in the file-index look-up routine #XFQELKUP
- XFQ2—Internal error in the file-index update routine #XFQEUPDT
- XFR1—An invalid FQE address has been passed to the file-transfer completion routine
CA Spool will initiate a termination with a user abend 0001 and a dump.
Action:
Restart ESF if possible, or notify the systems programmer. Report the failure and save the dump output.
Copyright © 2011 CA.